# Room-noise criteria (NC / RC Mark II)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/rooms/room-noise/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/rooms/room-noise/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-09
Updated: 2026-10-21T12:42:47Z
Standards: ANSI/ASA S12.2-2019
Verified: 3 conformance checks (ANSI/ASA S12.2-2019) https://docs.jmrp.io/phonometry/reference/conformance/#room-noise-ansi-s12-2-2019
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Room-noise ratings (ANSI/ASA S12.2-2019): NC curves with the tangency fallback, and RC Mark II with its rumble, hiss or neutral tag.

---

Steady background noise in an occupied room (from ventilation, diffusers or
distant traffic) is rated against a family of **octave-band criterion curves**.
**ANSI/ASA S12.2-2019**, *Criteria for Evaluating Room Noise*, defines two
spectrum-in ratings that phonometry implements: the **Noise Criteria (NC)**
rating (the NC-(SIL) designation of clause 5.2.2, with the tangency method
when the spectrum exceeds it), and the **Room Criteria Mark II (RC)** rating
with its rumble/hiss spectral tag. Both work on octave-band sound pressure
levels over the ten bands from 16 Hz to 8000 Hz.

![The two ANSI S12.2 rating methods from one octave-band spectrum: on the left the NC tangency method (from the Table 1 curves, the NC value in each band, then NC equals the highest curve touched, giving NC-NN with a governing band); on the right the RC Mark II method (the mid-frequency average LMF of the 500, 1000 and 2000 Hz levels rounded to give RC-NN, then the spectral tag R for rumble, H for hiss or N for neutral by the clause D.3 deviation rules)](https://docs.jmrp.io/phonometry/media/diagram_room_noise.svg)

## 0. Measuring the spectrum

Both ratings consume ten numbers, and the standard is specific about how those
ten numbers are obtained. Clause 5.2.5 (repeated at 5.1.2 for the A-weighted
criteria) fixes the instrument, the height and the clearances.

**The instrument and the quantity.** The measured quantity is
$L_{\mathrm{EQ}}$ per octave band, taken with an **integrating-averaging**
meter (not a needle read by eye). Clause 5.1.1 sets the floor for the
A-weighted criteria at a meter meeting at least the **class 2** requirements
of ANSI/ASA S1.4 Part 3 / IEC 61672-3; use a class 1 chain when the result
will be argued over. There are two admissible geometries: characterise a
**specific position**, in which case the microphone stands at that position,
or characterise the **whole space**, in which case the microphone is swept
slowly around it at **not more than 0.5 m/s for not less than 20 s**.

**Where the microphone goes.** At the occupants' ear height:
**1.6 m** standing and **1.2 m** seated for adults, **1.1 m** and **0.75 m**
for children; and no closer than **0.6 m** to any reflecting surface,
**1.2 m** to the intersection of two, or **2.4 m** to the intersection of
three. The standoff rule is the one that bites in a small room: a microphone
tucked into a corner sees pressure doubling in the low bands and can add
several decibels below 250 Hz, which is enough to fabricate a rumble tag or
to move the NC governing band.

**The operating condition.** The room is measured **unoccupied**, with the
services running at their **design condition**, not with the plant at part
load; the informative criteria of Annex C and Annex D are written for that
state, with human activity excluded. Intermittent events (a door, a printer,
a passing vehicle) are excluded from the integration or reported separately.

![Section through a 6.0 by 2.7 m office served from a ceiling plenum: the supply duct and diffuser above the ceiling and the air handler beyond the wall at its design condition, a seated occupant, the measurement microphone dimensioned 1.2 m above the floor with the 1.6 m standing height ghosted on the same stand, the 0.6 m, 1.2 m and 2.4 m microphone exclusion zones drawn against one surface, a two-surface edge and the trihedral corner, the alternative slow scan path at 0.5 metres per second for at least 20 seconds, and the clause 5.3.2 screening test that decides whether a single spectrum may be rated at all](https://docs.jmrp.io/phonometry/media/diagram_room_noise_setup.svg)

**Caution: The two lowest octaves are the fragile ones**

The standard's own NOTE to 5.2.5 records what makes 16 Hz and 31.5 Hz
awkward: at those wavelengths "pressure doubling may occur well beyond the
standoff distances given above", so a scan of a large space can come back
biased high; and "the lower the frequency, the narrower the bandwidth, and
hence, the greater the temporal fluctuation", so a short integration in a
16 Hz octave (only about 11 Hz wide) scatters. Use instrumentation with a
genuine response below 20 Hz, fit a windscreen even indoors, integrate for
long enough, and if the lowest bands are still suspect, report from 31.5 Hz
and say so. Both bands are load-bearing here: the RC tag and the NC
out-of-range label are read from them.

The octave-band arithmetic behind the input spectrum (filters, weighting,
energetic averaging) is in
[Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) and
[Filter Banks](https://docs.jmrp.io/phonometry/signals/filters/filter-banks/).

## 1. Noise Criteria: SIL designation and tangency

### Before you rate: is the noise steady?

**Caution**

Both single-spectrum ratings assume a **steady** sound field, and clause 5.3.2
makes that a test rather than an assumption. Screen the field for **surging**
and for **large random fluctuations** *before* computing either rating:

- **Surging** (5.3.2.1) is screened aurally and/or visually, watching the
  16, 31.5 and 63 Hz octave bands with the meter set to **fast** response
  and **Z** ("flat") weighting.
- **Large random fluctuations** (5.3.2.2) are screened from the differences
  $L_{\mathrm{MAX}} - L_{\mathrm{EQ}}$ and $L_{10} - L_{\mathrm{EQ}}$ in the
  16, 31.5, 63 and 125 Hz bands, again on fast, against Table 3:

  | Difference | Combined 16, 31.5 and 63 Hz | 125 Hz |
  | :--- | ---: | ---: |
  | $L_{\mathrm{MAX}} - L_{\mathrm{EQ}}$ | 7 dB | 6 dB |
  | $L_{10} - L_{\mathrm{EQ}}$ | 3.5 dB | 3 dB |

Exceed any of those and large random fluctuations are indicated. A field that
fails either screen belongs to the **RNC** method of clause 5.3, which needs a
time series rather than a single spectrum and which this module does not
implement, so `noise_criterion` and `room_criterion` would return a number
that is not the standard's answer for that room. Both functions assume the
screen has passed.

The **NC curves** (ANSI/ASA S12.2-2019 Table 1) are a family of octave-band
limits, each designated by its value at 1000 Hz (NC-15 up to NC-70). Clause
5.2.2 rates a spectrum in **two steps**. First the **speech interference
level** $\mathrm{SIL}$ (clause 3.2, the average of the 500/1000/2000/4000 Hz
levels) selects the NC-(SIL) curve: if no octave band exceeds it, the
spectrum is simply designated **NC-(SIL)**. Only when the spectrum pokes
above that curve does the **tangency method** (clause 5.2.3) take over: for
each octave band, the NC index whose curve passes through the measured level
is found, and the rating is the maximum across bands. The band where that
maximum occurs, the one that pushes the spectrum up against the curves, is
reported as the **governing band**.

```python
import numpy as np
from phonometry import room

# Octave-band SPL, 16 Hz - 8000 Hz (a ventilation-dominated room).
spl = np.array([62.0, 62.0, 59.0, 57.0, 52.0, 42.0, 35.0, 29.0, 24.0, 19.0])

nc = room.noise_criterion(spl)
print(round(nc.sil, 1))           # 32.5   (clause 3.2)
print(nc.method)                  # 'tangency'  (the NC-32 curve is exceeded)
print(round(nc.rating, 1))        # 42.5
print(nc.governing_frequency)     # 250.0  (the tangent band)
print(nc.label)                   # 'NC-42.5 (250 Hz)'
nc.plot()   # the spectrum over the NC curve family (left panel below)
```

Because a tangency rating interpolates between the tabulated curves it is a
continuous number: an NC rating of $42.5$ sits half-way between NC-40 and
NC-45 (a SIL designation is always an integer). The tangency rating is kept
on `tangency_rating` even when the SIL designation applies. A subset of the
octave bands may be supplied together with their centre frequencies
(`room.noise_criterion(levels, frequencies=frequencies)`); without the four SIL bands the
tangency rating alone sets the designation.

The Table 1 family ends at NC-70 and NC-15, and the standard defines no
rating beyond it. A spectrum above the NC-70 curve (or entirely below the
NC-15 curve) therefore gets `rating = nan` and an `out_of_range` flag of
`"above"` / `"below"`, with `nc.label` reading `'>NC-70 (63 Hz)'` (the band
with the largest exceedance over NC-70 governs) or `'<NC-15'`; no `NC-71` or
`NC-14` style numbers are ever fabricated.

### Reading the low-frequency excess

The tangency rating stops at "which band?", but clause 5.2.4 goes one step
further and asks "by how much, and does it matter?". The procedure is four
steps, in the standard's order: compute the SIL; select the NC criterion
curve **with the same number** as the SIL; plot the measured spectrum against
that curve; and read the differences in the octave bands **below 500 Hz**
against Table 2.

| Deviation above the NC-(SIL) curve | 31.5 Hz | 63 Hz | 125 Hz | 250 Hz |
| :--- | :---: | :---: | :---: | :---: |
| Possible serious dissatisfaction | — | 6–9 dB | 6–9 dB | 6–9 dB |
| Likely serious dissatisfaction | — | > 9 dB | > 9 dB | > 9 dB |

The 31.5 Hz column is blank in the standard because there were not enough
data to quantify it. That is worth knowing, because these bands are not a
model: they come from *measured* spectra in offices, lecture halls and
meeting rooms where the low-frequency noise had already been severe enough to
require remedial work on the HVAC system. So the procedure is diagnostic, not
pass/fail: more than 9 dB over the curve in any one of the 63, 125 or 250 Hz
bands means complaints strong enough to require remedial action are *likely*.
The table's footnote adds the other half of the story: in some of those same
rooms the 31.5 Hz levels were high enough to indicate clearly perceptible
vibration and rattle, which is the condition behind the $RV$ tag this module
does not implement.

Everything the procedure needs is already on the result: `nc.sil` selects the
curve, `nc.levels` carries the measured spectrum, and `verbose=True` on the
fiche (section 4) prints the per-band NC contour the tangency method read.

## 2. Room Criteria Mark II: rating and spectral tag

The **RC Mark II** curves (ANSI/ASA S12.2-2019 Annex D, Table D.1) have a
constant slope of **−5 dB/octave**, keyed to their value at 1000 Hz, with the
16 Hz level equal to the 31.5 Hz level and a low-frequency floor of 55 dB.
The numerical rating is the **mid-frequency average** $L_\text{MF}$, the mean of
the 500, 1000 and 2000 Hz levels, rounded to the nearest decibel (clause D.4):

$$
L_\text{MF} = \tfrac{1}{3}\left(L_{500} + L_{1000} + L_{2000}\right),
\qquad \text{RC} = \operatorname{round}(L_\text{MF}).
$$

A **spectral tag** then describes the *character* of the noise by how the
spectrum deviates from the reference RC curve (clause D.3): **rumble** ($R$)
when a band at or below 500 Hz exceeds the curve by more than 5 dB, **hiss**
($H$) when a band at or above 1000 Hz exceeds it by more than 3 dB, and
**neutral** ($N$) when neither happens.

None of those four shape rules is arbitrary. The **−5 dB per octave** slope is
the balance point at which a broadband ventilation background is heard as
bland rather than boomy or hissy, close enough to the ear's own falling
sensitivity that the spectrum carries no timbre of its own, which is why
Annex D was derived from 68 offices where nobody complained. The **55 dB
floor** on the low RC numbers exists because below it the question stops being
audibility and becomes perceptible **vibration and rattle** in lightweight
walls, ceilings and ductwork: that region is what the $RV$ tag and its
separate Table 6 test address, and it is the same effect the Table 2 footnote
recorded at 31.5 Hz. The **asymmetric tolerances** follow from where the
excess sits: a low-frequency excess is spread over the four bands at and below
500 Hz and is tolerated to 5 dB before it colours the sound, whereas a
high-frequency excess at or above 1 kHz lands squarely in the speech range and
is objectionable at 3 dB. The tag is computed only over the bands actually
supplied, which is why a spectrum missing bands still rates but emits a
`room.NoiseCriterionWarning`.

```python
import numpy as np
from phonometry import room

spl = np.array([62.0, 62.0, 59.0, 57.0, 52.0, 42.0, 35.0, 29.0, 24.0, 19.0])

rc = room.room_criterion(spl)
print(rc.label)             # RC-35(R)   -  a rumbly room
print(round(rc.lmf, 1))     # 35.3
print(rc.classification)    # R
rc.plot()   # the spectrum over the RC reference (right panel below)

# The whole Table D.1 family is one call away, so a design target exists
# before any spectrum does: rc_curve(index) returns the octave-band levels
# of a named RC curve over the same 16 Hz - 8 kHz bands.
target = room.rc_curve(35.0)
print(target.round(1))      # [60. 60. 55. 50. 45. 40. 35. 30. 25. 20.]
print((spl - target).round(1))   # [ 2.  2.  4.  7.  7.  2.  0. -1. -1. -1.]
```

That last line is the number a specification is written against: band by band,
how far the room sits above or below "RC-35(N)". `rc_curve` accepts any index,
while Table D.1 tabulates RC-25 to RC-50 only, which is what
`RCResult.out_of_family` flags.

The strong low-frequency content of this spectrum lifts the 63–250 Hz bands
well above the reference curve, so the noise is tagged $R$ (rumble): the
subjective "throb" of an oversized air handler.

![Two panels for the same ventilation-dominated room spectrum. Left: the measured octave-band levels over the NC curve family, with a red diamond marking the tangent point at 250 Hz that sets the NC-42.5 rating. Right: the same spectrum over the RC Mark II family drawn from RC-25 to RC-50, showing the constant minus 5 dB per octave slope running into the flat 55 dB low-frequency floor, with the reference RC-35 curve highlighted, the low-frequency bands rising through the shaded rumble tolerance (plus 5 dB below 500 Hz) so the noise is classified RC-35(R), and the hiss tolerance (plus 3 dB at and above 1000 Hz) shaded for comparison](https://docs.jmrp.io/phonometry/media/room_noise_criteria.svg)

*The same ten numbers read two ways. Left, the Table 1 NC family with the
250 Hz tangency that sets NC-42.5; right, the Table D.1 RC family, whose
−5 dB/octave lines flatten onto the 55 dB floor at 16 and 31.5 Hz, with the
measured spectrum breaking the +5 dB rumble tolerance of its RC-35 reference.*

**Show the code for this figure**

```python
import numpy as np
import matplotlib.pyplot as plt
from phonometry import room

spl = np.array([62.0, 62.0, 59.0, 57.0, 52.0, 42.0, 35.0, 29.0, 24.0, 19.0])

# One line each:
room.noise_criterion(spl).plot()
room.room_criterion(spl).plot()
plt.show()

# By hand, mirroring what NCResult.plot() / RCResult.plot() draw. Either
# family can also be built one curve at a time from the public helpers
# room.nc_curve(index) and room.rc_curve(index), which is what the RC panel
# below does; room.NC_OCTAVE_BANDS_HZ holds the ten bands of both.
nc, rc = room.noise_criterion(spl), room.room_criterion(spl)
fig, (ax1, ax2) = plt.subplots(1, 2, figsize=(12, 5))

bands = room.NC_OCTAVE_BANDS_HZ   # the ten octave bands of ANSI/ASA S12.2 Table 1
for row, idx in zip(room.NC_CURVE_LEVELS, room.NC_RATINGS):
    ax1.plot(bands, row, color="#bbbbbb", lw=0.8)
ax1.plot(bands, spl, "o-", label="Measured")
gov = spl[bands == nc.governing_frequency][0]
ax1.plot([nc.governing_frequency], [gov], "D", color="#d62728")
ax1.set_xscale("log"); ax1.set_title(f"NC-{nc.rating:g}")

for idx in range(25, 51, 5):        # the Table D.1 family, RC-25 to RC-50
    ax2.plot(bands, room.rc_curve(float(idx)), color="#bbbbbb", lw=0.8)
ref = rc.reference_curve
low, high = bands <= 500, bands >= 1000
ax2.plot(bands, ref, "s--", color="#7f7f7f", label=f"Reference RC-{rc.rating}")
ax2.fill_between(bands[low], ref[low], ref[low] + 5, color="#ffbb78", alpha=0.35)
ax2.fill_between(bands[high], ref[high], ref[high] + 3, color="#aec7e8", alpha=0.45)
ax2.plot(bands, spl, "o-", label="Measured")
ax2.set_xscale("log"); ax2.set_title(rc.label)
plt.show()
```

The `NCResult` carries the `rating`, the `sil`, the `tangency_rating`, the
`method` (`'SIL'` or `'tangency'`), the `governing_frequency`, the
`out_of_range` flag and the measured `levels`, plus a convenience `label`
(`'NC-44'`, `'NC-51 (125 Hz)'`, `'>NC-70 (63 Hz)'`); the `RCResult` carries
the `rating`, the `lmf`, the `classification`, the `reference_curve`, an
`out_of_family` flag (Table D.1 tabulates RC-25 through RC-50 only) and a
convenience `label` in the `RC-NN(A)` form. Clause D.3.5 admits the tags
$N$, $R$, $H$ or $RV$; when both the rumble and hiss deviations fire, the
library reports the combined `RH` as a diagnostic extension. Each result
exposes a `.plot()` that renders its panel above. Clause D.4 expects at
least the 31.5 Hz to 4000 Hz octave bands: a spectrum missing any of them
still rates, but emits a `room.NoiseCriterionWarning` because the absent
bands are skipped by the tag deviation tests.

## 3. Choosing a criterion: NC, RC Mark II or NR

### What rating a room should meet

A rating on its own is not an answer, and the standard knows it: S12.2 pairs
each method with an informative table of recommended criteria by occupancy:
an A-weighted table (Annex C, Table C.1), an NC/RNC table (Annex C, Table C.2,
which clause 5.2.6 points at) and an RC Mark II table (Annex D, Table D.2). A
specification normally cites one of them, or a national equivalent. Anchors
from the NC/RNC table:

| Occupancy | Recommended NC / RNC |
| :--- | :---: |
| Concert halls, opera houses, recital halls | 15–18 |
| TV and broadcast studios (close pickup) | 15–25 |
| Large auditoriums and drama theatres (> 500 seats) | 20–25 |
| Small auditoriums (≤ 500 seats) | 25–30 |
| Bedrooms | 25–30 |
| Lecture and classrooms, core learning space ≤ 566 m³ | 25–30 |
| Lecture and classrooms, core learning space > 566 m³ | 30–35 |
| Apartments, family and living rooms | 30–40 |
| Hotel individual rooms or suites | 30–35 |
| Open-plan office areas | 35–40 |
| Hotel service support areas | 40–50 |

These are **informative** and **unoccupied** values, with the noise of human
activity excluded, and the RC table adds `(N)` to every entry: only a neutral
spectrum should normally be accepted as a specification (clause D.3.1). Read
them as ranges: a rating inside the range complies, and the governing band
tells you where the margin is thinnest. They are also written for **steady**
noise, so an intermittent source is assessed separately and, per the screen
at the head of section 1, a fluctuating or surging one is not assessed by
these methods at all.

### The two numbers are not on the same scale

The spectrum of section 1 rates **NC-42.5** and the same spectrum in section 2
rates **RC-35**. Nothing went wrong: they are different scales and must never
be substituted for one another. NC by tangency is set by the single worst
band wherever it falls (here the 250 Hz rumble), while the RC number is the
arithmetic mean of the 500, 1000 and 2000 Hz levels and ignores everything
else in its numeric part, moving the character of the spectrum into the tag
instead. A rumbly spectrum therefore always rates worse on NC than on RC, and
the size of the NC-minus-RC gap is itself a measure of the imbalance; a room
where the two agree closely already follows the criterion shape. The
specification rule follows: rate against whichever family the specification
cites, report both when the client wants a diagnosis, and never claim
compliance with an NC limit using an RC value, or the reverse.

The corollary is the one worth carrying away. Two rooms can share an NC rating
and sound nothing alike:

![Two octave-band spectra that both rate NC-40. Left panel: over the NC curve family, a duct-rumble spectrum touching the NC-40 curve at 125 Hz and a diffuser-hiss spectrum touching the same curve at 4000 Hz, with one rating printed for both. Right panel: the same two spectra as deviations from their own RC Mark II reference curves, against the clause D.3 step threshold of plus 5 dB at and below 500 Hz and plus 3 dB at and above 1000 Hz, so the rumble spectrum breaks the threshold at low frequency and is tagged RC-34(R) while the hiss spectrum breaks it at high frequency and is tagged RC-36(H)](https://docs.jmrp.io/phonometry/media/nc_blind_spot.svg)

*Both rooms are NC-40, and the tangency method has nothing left to say about
the difference. The right panel plots each spectrum against its **own** RC
reference curve: the duct-rumble room runs 7–8 dB over it below 250 Hz, the
diffuser room 12–13 dB over it above 2 kHz, and the D.3 threshold turns that
into one letter: RC-34(R) against RC-36(H).*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
# `room` is the import of the section 1 snippet above.

bands = np.array([16, 31.5, 63, 125, 250, 500, 1000, 2000, 4000, 8000])
rumbly = np.array([66.0, 64.0, 62.0, 56.0, 48.0, 40.0, 34.0, 28.0, 24.0, 19.0])
hissy = np.array([52.0, 52.0, 50.0, 46.0, 43.0, 39.0, 35.0, 34.0, 38.0, 34.0])

for spectrum in (rumbly, hissy):
    nc, rc = room.noise_criterion(spectrum), room.room_criterion(spectrum)
    print(nc.label, rc.label)     # NC-40 (125 Hz) RC-34(R) / NC-40 (4000 Hz) RC-36(H)

# The right panel: each spectrum against its own reference curve, with the
# clause D.3 threshold as one step (+5 dB below 500 Hz, +3 dB above).
threshold = np.where(bands <= 500.0, 5.0, 3.0)
fig, ax = plt.subplots()
ax.step(bands, threshold, where="mid", ls="--", color="k", label="Tag threshold")
for spectrum, name in ((rumbly, "Duct rumble"), (hissy, "Diffuser hiss")):
    rc = room.room_criterion(spectrum)
    ax.plot(bands, spectrum - rc.reference_curve, "o-", label=f"{name} — {rc.label}")
ax.set_xscale("log")
ax.set_xlabel("Octave-band center frequency [Hz]")
ax.set_ylabel("Level minus the room's own RC curve [dB]")
ax.legend()
plt.show()
```

The two ratings answer different questions, and a third family exists
that this module deliberately does not implement:

- **NC** answers *"does the room meet its limit, and which band breaks
  it?"*. It is the compliance rating of North-American practice
  (specifications, codes, equipment schedules). The clause 5.2.2 SIL step
  anchors the designation to speech interference, but the moment any band
  exceeds the NC-(SIL) curve the tangency method takes over and is driven
  entirely by the single governing band. That is also its blind spot: two
  NC-40 rooms can sound completely different, one rumbly and one hissy,
  because tangency says nothing about spectral balance. Use NC when a
  specification cites it, and always report the governing band with a
  tangency rating, since it names the octave any fix must attack first.
- **RC Mark II** answers *"how does the room sound, and what should be
  fixed?"*. Its rating tracks speech interference through the
  mid-frequency average, and its reference slope of −5 dB per octave is
  the spectrum occupants describe as neutral, a bland ventilation
  background that is neither boomy nor sharp. The spectral tag then points
  at the offending frequency range. Reach for RC Mark II at HVAC design
  time, or to diagnose an installation that fails its NC limit.
- **NR (Noise Rating)**, the curve family of Kosten & van Os (1962), is
  the European counterpart of NC: the same tangency logic over a
  slightly different curve family (more permissive
  at low frequency, stricter at high), common in European and
  international equipment and building specifications. phonometry does not
  implement NR; when a specification cites NR, rate against the NR curves
  themselves rather than substituting NC, because the two families diverge
  by several decibels away from the mid frequencies.

**Reading the tag.** The RC Mark II tag is a repair hint, not just a label.
A rumble tag (`R`, more than 5 dB over the reference at or below 500 Hz)
points at the air-handling plant: an oversized or starved fan, duct
rumble, or structure-borne vibration re-radiated by walls, and it is the
low-frequency energy that rattles lightweight construction and fatigues
occupants. A hiss tag (`H`, more than 3 dB over at or above 1000 Hz)
points at the terminal end: diffuser and grille face velocities or a
throttled damper close to the outlet, and it is the range that masks
speech. A neutral tag (`N`) means the level can still be wrong, but the
character is right: reduce the whole spectrum rather than reshape it, which
usually means more room absorption rather than more duct lining, so it hands
the problem to
[Reverberation-time prediction](https://docs.jmrp.io/phonometry/buildings/rooms/reverberation-prediction/)
and
[Sound absorption in enclosed spaces](https://docs.jmrp.io/phonometry/buildings/rooms/enclosed-space-absorption/).

## 4. Room-noise reports (`.report()`)

Both ratings render a one-page PDF room-noise assessment fiche.
`NCResult.report(path)` and `RCResult.report(path)` share the same layout: a
standard-basis line, an optional metadata header block, the measured
octave-band levels beside the measured spectrum plotted against the NC/RC curve
family (the result's own `.plot()`), the boxed rating, an optional verdict row
and a footer with the fixed disclaimer. The NC box shows the `NC-nn`
designation with the SIL and, for a tangency rating, its governing band
(`>NC-70` / `<NC-15` when the spectrum falls outside the Table 1 family); the
RC box shows `RC-nn(tag)` with the mid-frequency average
$L_\text{MF}$ and the spectral quality. A lower rating is quieter, so a
`requirement` on the metadata (read as the maximum acceptable NC or RC rating)
passes at or below the target. Setting `verbose=True` adds the per-band NC
contour value read by the tangency method (NC), or the reference RC Mark II
curve and the measured deviation from it (RC). Both use the same
`ReportMetadata` container as the other fiches; the room-specific `room_volume`
and `area` populate the header alongside `client`, `test_room`, `specimen`,
`instrumentation`, the climate fields, `measurement_standard`, `test_date`,
`laboratory`, `operator` and `report_id`. Passing `metadata=None` produces a
bare assessment fiche. Rendering needs reportlab and, for the figure the fiche
embeds, matplotlib (`pip install "phonometry[report,plot]"`); only
`engine="reportlab"` is supported, and `language="es"` renders a Spanish fiche
(translated fixed strings and a comma decimal separator).

```python
import numpy as np
from phonometry import room, ReportMetadata

spl = np.array([79.0, 69.0, 59.0, 51.0, 50.0, 39.0, 36.0, 34.0, 33.0, 32.0])
metadata = ReportMetadata(
    test_room="Office A", room_volume=180.0, area=60.0,
    measurement_standard="ANSI/ASA S12.2",
    laboratory="Phonometry Reference Laboratory",
    requirement=40.0,              # adds a verdict against a target rating
)
room.noise_criterion(spl).report("nc_fiche.pdf", metadata=metadata)
room.room_criterion(spl).report("rc_fiche.pdf", metadata=metadata)
```

The example fiches are regenerated with `make reports` and kept rendered in the
repository; click a preview to open the PDF.

**Report:** [ANSI/ASA S12.2 Noise Criteria example report (PDF)](https://docs.jmrp.io/phonometry/media/ansi_s12_2_noise_criteria_example.pdf): One-page room-noise assessment fiche: a metadata header (client, room, description, room volume, floor area, instrumentation and climate), the measured octave-band level table beside the measured spectrum over the NC curve family, and the boxed NC-40 rating with the 250 Hz governing band and a PASS verdict against a target of 40.

Noise Criteria fiche (NCResult.report), the NC rating and its governing band.

**Report:** [ANSI/ASA S12.2 Room Criteria example report (PDF)](https://docs.jmrp.io/phonometry/media/ansi_s12_2_room_criteria_example.pdf): One-page room-noise assessment fiche: a metadata header, the measured octave-band level table beside the measured spectrum over the reference RC Mark II curve with the rumble and hiss tolerance bands shaded, and the boxed RC-35(R) rating with the mid-frequency average LMF and a rumble spectral quality.

Room Criteria fiche (RCResult.report), the RC rating and its spectral tag.

## What this guide covers

- **Covered.** ANSI/ASA S12.2-2019 Table 1 and clauses 5.2.2/5.2.3 (the NC-(SIL) designation
  and the tangency method with its governing band) through
  `room.noise_criterion`; and the informative Annex D RC Mark II family of Table
  D.1 (`room.rc_curve`) with the clause D.4 mid-frequency-average rating and the
  clause D.3 neutral/rumble/hiss tag, through `room.room_criterion`. Both work
  over the ten octave bands from 16 Hz to 8 kHz, and each result renders its own
  one-page fiche through `.report()`. The clause 5.2.5 measurement conditions,
  the clause 5.2.4 low-frequency-excess procedure and the Annex C / Annex D
  criterion tables are quoted here for planning and reading.

- **Not covered.** The clause 5.3.2 screening test is described in section 1 but not implemented:
  the reader must perform it, because a spectrum that fails it is outside the
  domain of both functions. The balanced noise criteria (NCB), the room noise
  criterion for fluctuating low-frequency noise (RNC, which needs a time series
  rather than a single spectrum), the vibration/rattle tag ($RV$, which needs
  the Table 6 test) and the numeric quality-assessment index (QAI, which the
  standard defers to external references) are not part of this module. Neither
  is the NR curve family (see section 3). The criterion tables are reproduced
  only as anchors: check the standard, or the national or client document that
  governs the job, before quoting a limit.

## See also

- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the ISO 3382
  decay parameters of the same room, measured from an impulse response.
- [Reverberation-time prediction](https://docs.jmrp.io/phonometry/buildings/rooms/reverberation-prediction/)
  and
  [Sound absorption in enclosed spaces](https://docs.jmrp.io/phonometry/buildings/rooms/enclosed-space-absorption/):
  the absorption that lowers a whole spectrum once the tag says the character
  is right.
- [Speech Transmission Index](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/):
  the intelligibility that both criterion families were built to protect.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/) and
  [Filter Banks](https://docs.jmrp.io/phonometry/signals/filters/filter-banks/): the octave-band
  measurement that produces the input spectrum.
- [Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/):
  when the source is next door rather than overhead.
- API reference: [`room.noise_criteria`](https://docs.jmrp.io/phonometry/reference/api/rooms/noise-criteria/).
- Theory: [Room noise criteria (ANSI S12.2)](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/#room-noise-criteria-ansi-s122): how the NC, RC Mark II and NR families are constructed and what each was designed to penalise.

## References

- **Acoustical Society of America. (2019).** [*Criteria for evaluating room noise*](https://webstore.ansi.org/standards/asa/ansiasas122019) (ANSI/ASA S12.2-2019).
  The normative NC curves and tangency method (Table 1), plus, from the informative Annex D, the RC Mark II curves (Table D.1), the mid-frequency-average rating (clause D.4) and the neutral/rumble/hiss spectral tag (clause D.3), that this module implements.
- **Beranek, L. L. (1957).** Revised criteria for noise in buildings. *Noise Control*, *3*(1), 19-27. https://doi.org/10.1121/1.2369239
  The paper that introduced the NC curves and the speech-interference reasoning behind them.
- **Blazier, W. E. (1997).** RC Mark II: A refined procedure for rating the noise of heating, ventilating, and air-conditioning (HVAC) systems in buildings. *Noise Control Engineering Journal*, *45*(6), 243-250. https://doi.org/10.3397/1.2828446
  The refined RC procedure, with its neutral-spectrum rationale and the rumble/hiss regions, that ANSI/ASA S12.2 Annex D codifies.
- **Kosten, C. W., & van Os, G. J. (1962).** [Community reaction criteria for external noises](https://openlibrary.org/books/OL58781133M). *The Control of Noise (National Physical Laboratory Symposium No. 12)*, 373-387.
  The paper that introduced the NR curve family the text contrasts with NC. Published by Her Majesty's Stationery Office; the linked record is the Open Library page.