# Measuring the Room Impulse Response

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/rooms/room-impulse-response/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/rooms/room-impulse-response/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-28
Updated: 2026-11-16T21:36:10Z
Standards: ISO 18233:2006
Verified: 1 conformance checks (ISO 18233:2006) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Room impulse response measurement with the ISO 18233 excitations: the exponential sine sweep, MLS, and source and microphone placement.

---

Every room-acoustic quantity on this site starts from the same measurement:
the **impulse response** (IR) between a source and a receiver. Get it right
and everything downstream (reverberation time, clarity, insulation, speech
metrics) is a matter of arithmetic; get it wrong and no later processing
recovers what the excitation or the microphone position threw away. This
guide covers the acquisition itself, per ISO 18233: the exponential sine
sweep and its deconvolution, the MLS correlation method, and where to place
sources and microphones so the averaged result means something. Turning the
measured IR into room parameters lives in
[Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/); the same IR measured
either side of a partition becomes sound insulation in
[Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/).

## Two deterministic excitations (ISO 18233)

A room behaves, to a good approximation, as a **linear time-invariant**
system, so everything about it is contained in its IR. You could fire a
pistol and record the tail, but a deterministic excitation played through
a loudspeaker and *deconvolved* recovers the same IR with 20–30 dB more
effective signal-to-noise ratio (ISO 18233 clause 6.2.3). Two excitations
are provided.

![Three recoveries of the same synthetic room impulse response against the same background noise, plotted as smoothed log envelopes against time: a pistol shot recorded directly reaches 46 dB between its peak and the noise floor, a 1 second deconvolved sweep reaches 75 dB, and a 4 second sweep reaches 83 dB, with the floor read in a bracketed window from 1.0 to 1.6 seconds after the room decay has died away](https://docs.jmrp.io/phonometry/media/deconvolution_snr_gain.svg)

*The same room, the same background noise, three excitations. The pistol
recovers 46 dB of range; a 1 s deconvolved sweep recovers 75 dB, the 29 dB
that clause 6.2.3 predicts. Two further doublings of the sweep add 8 dB,
B.6 quotes about 3 dB per doubling as the normal figure, and the extra here
is the deconvolution's own noise tail (B.5) falling away with the longer
sweep. The number quoted is the peak-to-floor distance, with the floor read
as the RMS of the bracketed window, long after the room has stopped.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy.signal import fftconvolve
from phonometry import room

fs, n = 48000, 96000
rng = np.random.default_rng(2026)
t = np.arange(n) / fs
system = rng.standard_normal(n) * np.exp(-6.9077 * t / 0.7) * 0.02
system[80] += 1.0; system[1500] += 0.45; system[3200] += 0.28
noise = 10.0 ** (-46.0 / 20.0)          # the room's own background
win = slice(int(1.0 * fs), int(1.6 * fs))

def peak_to_floor(h):
    mag = np.abs(np.asarray(h, dtype=float))
    return 20 * np.log10(mag.max() / np.sqrt(np.mean(mag[win] ** 2)))

shot = system + rng.standard_normal(n) * noise
print(round(peak_to_floor(shot)))                 # 46

for seconds in (1.0, 4.0):
    sweep = room.sweep_signal(fs, 20.0, 20000.0, seconds)
    played = fftconvolve(sweep, system)
    played = played + rng.standard_normal(played.size) * noise
    ir = room.impulse_response(played, sweep, fs, length=n)
    print(seconds, round(peak_to_floor(ir)))      # 1.0 75 / 4.0 83
    plt.plot(t, 20 * np.log10(np.abs(np.asarray(ir)) / np.max(np.abs(np.asarray(ir)))))
plt.show()
```

**Exponential sine sweep (ESS, Annex B).** The instantaneous frequency
rises exponentially,

$$
f(t) = f_1 \left( \frac{f_2}{f_1} \right)^{t/T},
$$

so the time spent per octave is constant and the excitation mimics
pink noise (constant energy per fractional-octave band). The IR is
recovered by linear (zero-padded, non-circular) spectral division,

$$
H = \frac{Y\ \overline{X}}{|X|^2 + \varepsilon},
$$

with a small Tikhonov term $\varepsilon$ guarding the band edges where the
sweep has little energy.

The deconvolution *divides* by the reference spectrum, so wherever the sweep
put no energy there is nothing to divide by, and the Tikhonov term is all
that stops the quotient exploding. That is why the sweep starts **below** the
lowest band to be analysed and ends **above** the highest (typically 20 Hz to
20 kHz for a room analysed from 125 Hz to 4 kHz), since the analysis filters
need energy across their skirts as well as at their centres. The symptom of
getting it wrong is recognisable: a slow rumble *before* the direct sound, or
a ringing high-frequency tail, either of which lifts the apparent noise floor
of the edge bands and shortens their fitted decay times. The rule is to widen
the sweep first and raise `regularization` only when the loudspeaker genuinely
cannot reproduce the band, and to record the value used, because it changes
the result.

Because a low-to-high sweep places harmonic distortion at *negative* arrival
times, distortion separates cleanly from the linear IR and is discarded by
keeping only the causal part. The mechanism is one sentence: the instantaneous
frequency of an exponential sweep advances by a fixed number of octaves per
second, so the $k$-th harmonic traces the same frequency path a fixed time
*earlier*, and after deconvolution the distortion collapses into discrete
packets at negative delays separated by

$$
\Delta t_k = T\,\frac{\ln k}{\ln (f_2/f_1)} .
$$

Three practical consequences follow. The separation is proportional to the
sweep length, so a long sweep pushes the packets safely away from $t = 0$
while a very short one lets the second-order packet crowd the linear
response. The packets are the raw material of the swept-sine distortion
analysis, which is why `return_full=True` exists. And this separation is why
a sweep tolerates a loudspeaker driven near its limit, whereas MLS spreads
the same distortion over the whole IR as noise.

![The full deconvolved sequence of a 3 second sweep through a mildly nonlinear chain, plotted on a wrapped time axis with zero in the middle: the linear impulse response at t = 0 with the causal window shaded to its right, and the second, third and fourth harmonic packets as separate clusters at minus 0.30, minus 0.48 and minus 0.60 seconds, each marked with its predicted advance](https://docs.jmrp.io/phonometry/media/sweep_distortion_separation.svg)

*`return_full=True` on the same 3 s, 20 Hz to 20 kHz sweep, with a mild
memoryless nonlinearity in the chain. The H2, H3 and H4 clusters land at
$-\Delta t_k$, and the default return simply keeps the shaded half.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy.signal import fftconvolve
# `room` is the import of the main snippet below.

fs, f1, f2, seconds = 48000, 20.0, 20000.0, 3.0
sweep = room.sweep_signal(fs, f1, f2, seconds)
system = np.zeros(int(0.4 * fs))
system[80], system[1400], system[3100] = 1.0, 0.5, 0.32

played = fftconvolve(sweep, system)
played = played + 0.08 * played ** 2 + 0.04 * played ** 3 + 0.02 * played ** 4
full = np.asarray(room.impulse_response(played, sweep, fs, return_full=True))

for order in (2, 3, 4):
    print(order, round(seconds * np.log(order) / np.log(f2 / f1), 2))
# 2 0.3 / 3 0.48 / 4 0.6   -- the predicted advances, in seconds

half = full.size // 2
plt.plot((np.arange(full.size) - half) / fs,
         20 * np.log10(np.abs(np.roll(full, half)) / np.max(np.abs(full))))
plt.xlim(-0.78, 0.42); plt.ylim(-95, 18)
plt.show()
```

The `"farina"` method reaches the same result by convolving the recording with
the analytic inverse filter; it assumes the reference sweep was generated
with the default amplitude and fade, so use the spectral method for a
non-unit-amplitude or custom-fade sweep.

**Maximum-length sequence (MLS, Annex A).** An order-$N$ binary sequence of
length $2^N-1$ whose circular autocorrelation is a near-perfect delta; the
IR follows from circular cross-correlation of the recorded period with the
sequence. MLS excites at constant amplitude and is quick to average, but it
is more sensitive to time variance (draughts, temperature drift) and cannot
be fed as much power as a sweep. **Prefer the sweep** for rooms and
partitions; reach for MLS when the excitation must be periodic or the
hardware favours a two-level signal.

### Dimensioning the excitation

Both excitations are sized against one number the reader already has: the
room's reverberation time $T$. Get the sizing wrong and nothing looks broken;
the result is simply short.

**The sweep and its silence.** Start the sweep below the lowest analysis band
and end it above the highest. Clause B.3.1 calls a length of **two to four
times the longest expected $T$**, followed by a **silent gap of about one
$T$**, safe practice under moderate background noise; clause 6.2.2.3 makes
the gap normative (the excitation "shall be succeeded by a period of
silence"), and the decay shall be recorded over at least half of $T$. Keep the
record running until every band of interest is at least 30 dB down. Then, per
B.6, each doubling of the sweep buys about 3 dB of effective SNR, and a longer
sweep is preferred over more averages: averaging responses raises the
sensitivity to changes in the environment, while one long sweep does not.

**The MLS period.** A periodic excitation is different, and clause 6.2.2.2 is
normative about it (Eq. (10)): the repetition period **shall not be shorter
than $T$**, so that at least two spectral lines fall inside the bandwidth of
any room mode. Since the period of an order-$N$ sequence is $(2^N-1)/f_\mathrm{s}$,
that fixes the order:

$$
N \geq \frac{\lg\!\left(T f_\mathrm{s} + 1\right)}{\lg 2} .
$$

At 48 kHz, order 16 gives 1.37 s and order 18 gives 5.46 s, and a room with
$T = 1.5$ s needs order 17. Go below that and the tail of one period folds
onto the head of the next: the decay is time-aliased, the level floor rises
and $T$ comes out short, with no visible symptom. Discard the first period as
warm-up, which is what the four-periods-play, three-periods-keep pattern
below does.

![Three time lanes for a room with T = 1.2 s. The first shows the played sweep of 4.0 seconds, three and a third times T, followed by a silent gap of about one T and a bracketed record window of 5.2 seconds. The second shows a periodic MLS of order 17, period 2.73 seconds, with the first period marked as warm-up and discarded and the second kept, and below it a short order-15 period of 0.68 seconds marked as shorter than T so the tail folds onto the head. The third shows what the deconvolution returns: the linear impulse response and its tail at time zero with the causal part kept, the second, third and fourth harmonic packets at negative arrival times, and the deconvolution's own decaying noise tail](https://docs.jmrp.io/phonometry/media/diagram_sweep_budget.svg)

```python
import numpy as np
# `room` is the import of the figure block above.

def excitation_budget(reverberation, fs=48000, factor=3.0):
    """Sweep length, silence and the MLS order a room of this T needs."""
    sweep_seconds = factor * reverberation                   # B.3.1: 2-4 x T
    silence = reverberation                                  # B.3.1: about T
    order = int(np.ceil(np.log2(reverberation * fs + 1.0)))  # 6.2.2.2 Eq. (10)
    period = (2 ** order - 1) / fs
    return round(sweep_seconds, 2), round(silence, 2), order, round(period, 2)

print(excitation_budget(1.2))    # (3.6, 1.2, 16, 1.37)
print(excitation_budget(1.5))    # (4.5, 1.5, 17, 2.73)
```

![Four recovered impulse-response envelopes from the same synthetic room: the sweep recovered under stationary conditions and under a slow warming of 0.3 kelvin lie on top of each other and reach 90 dB below the peak, the stationary MLS follows them to about 75 dB, and the drifted MLS collapses to a flat floor 15 dB below the peak with no decay left](https://docs.jmrp.io/phonometry/media/excitation_robustness.svg)

*What "more sensitive to time variance" costs. A slow warming of about 0.3 K
across the take (a resampling of 500 parts per million, which is what a
falling speed of sound does to the arrival times) leaves the sweep recovery
unchanged and destroys the MLS one, because the correlation averages periods
that no longer line up. ISO 18233 B.7.3.1 states the same result
qualitatively; A.4.3.1 Eq. (A.8) gives the guide limit
$\Delta\vartheta \leq 200/(f\,T)$ °C for a reverberation-time measurement.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from scipy.signal import fftconvolve
# `room` is the import of the main snippet below.

fs, n = 48000, 24000
rng = np.random.default_rng(2026)
t = np.arange(n) / fs
system = rng.standard_normal(n) * np.exp(-6.9077 * t / 0.4) * 0.02
system[80] += 1.0; system[1500] += 0.45; system[3200] += 0.28

def drift(x, ppm):                      # the room warming during the take
    i = np.arange(x.size, dtype=float)
    return np.interp(i, i * (1.0 + ppm * 1e-6 * i / x.size), x, left=0.0, right=0.0)

sweep = room.sweep_signal(fs, 20.0, 20000.0, 1.4)
mls = room.mls_signal(16)
for ppm in (0.0, 500.0):
    played = drift(fftconvolve(sweep, system), ppm)
    plt.plot(20 * np.log10(np.abs(np.asarray(
        room.impulse_response(played, sweep, fs, length=n)))))
    # Four periods played, the first discarded as warm-up. The drifted case
    # trips the library's circular-aliasing warning: that warning IS the result.
    rec = drift(fftconvolve(np.tile(mls, 4), system)[mls.size: 4 * mls.size], ppm)
    plt.plot(20 * np.log10(np.abs(np.asarray(
        room.mls_impulse_response(rec, mls, length=n)))))
plt.show()
```

![ISO 18233 indirect measurement chain: an ESS sweep or MLS excitation drives a loudspeaker into the room, a microphone captures the response, and deconvolution (correlation or inverse filter) recovers the impulse response](https://docs.jmrp.io/phonometry/media/diagram_ir_measurement.svg)

```python
import numpy as np
from scipy.signal import fftconvolve
from phonometry import room

fs = 48000
# A 3 s, 20 Hz - 20 kHz sweep is a good broadband room excitation
# sweep: excitation you play through the loudspeaker
sweep = room.sweep_signal(fs, 20.0, 20000.0, 3.0)

# Deconvolve the recorded response back to the impulse response
system = np.zeros(fs); system[100] = 1.0; system[2000] = 0.4   # direct + reflection
# recorded: mic capture of the played sweep (here simulated by convolution with a synthetic room)
recorded = fftconvolve(sweep, system)
ir = room.impulse_response(recorded, sweep, fs, method="spectral")
print(int(np.argmax(np.abs(ir))))                    # 100: direct sound recovered
ir.plot()                     # waveform + Schroeder envelope (figure below)

# Farina inverse-filter variant (needs the sweep band)
ir_f = room.impulse_response(recorded, sweep, fs, method="farina", f_range=(20.0, 20000.0))

# Periodic MLS: excite with >= 2 periods, average, cross-correlate
mls = room.mls_signal(16)                                 # length 2**16 - 1 = 65535
rec = fftconvolve(np.tile(mls, 2), system)[: 2 * mls.size]
ir_m = room.mls_impulse_response(rec, mls)
print(int(np.argmax(np.abs(ir_m))))                  # 100
```

`sweep_signal`/`mls_signal` return plain arrays, ready to write to a WAV file
and play. `impulse_response`/`mls_impulse_response` return an
`ImpulseResponseResult`, a drop-in for the raw IR array (`np.asarray(ir)`,
indexing and `ir.size` all keep working, so `room_parameters(ir, fs)` is
unchanged) that also carries the sample rate and method and adds a `.plot()`.
Two more excitations from the transfer-function literature (complementary
Golay pairs, whose deconvolution is exact and noise-free, and sweeps shaped to
an arbitrary target spectrum) live in the
[system-measurement guide](https://docs.jmrp.io/phonometry/signals/spectra/system-measurement/) and
return the same result types.

**The two excitations.** The exponential sweep sweeps its energy up the
spectrum over the whole signal, while the MLS is a flat-spectrum two-level
sequence, visible as the near-constant magnitude on the right.

![ISO 18233 excitation signals: the exponential sine sweep waveform and its spectrogram showing the exponential frequency rise, and a maximum-length sequence with its flat magnitude spectrum](https://docs.jmrp.io/phonometry/media/excitation_signals.webp)

**Show the code for this figure**

```python
from phonometry import room

fs = 48000
sweep = room.sweep_signal(fs, 50.0, 20000.0, 1.0)   # ESS excitation
mls = room.mls_signal(12).astype(float)             # length 2**12 - 1

# One-liner: waveform + spectrogram (sweep), sequence + flat spectrum (MLS)
room.plot_excitation(sweep, fs, kind="sweep")
room.plot_excitation(mls, fs, kind="mls")

# By hand: the sweep spectrogram and the MLS magnitude spectrum
import numpy as np
import matplotlib.pyplot as plt

fig, (ax1, ax2) = plt.subplots(1, 2, figsize=(12, 4))
ax1.specgram(sweep, NFFT=1024, Fs=fs, noverlap=512)
ax1.set(xlabel="Time [s]", ylabel="Frequency [Hz]", title="Sweep spectrogram")
spec = np.abs(np.fft.rfft(mls))
freqs = np.fft.rfftfreq(mls.size, d=1.0 / fs)
ax2.semilogx(freqs[1:], 20 * np.log10(spec[1:] / np.median(spec[1:])))
ax2.set(xlabel="Frequency [Hz]", ylabel="Magnitude [dB]", title="MLS spectrum (flat)")
```

## The recovered impulse response

Deconvolving the recording gives the
broadband IR: the direct sound, discrete early reflections and the decaying
diffuse tail. Its `.plot()` shows the waveform above and the log-magnitude
envelope with the Schroeder energy-decay curve below: the straight decay
whose slope becomes the reverberation time in the
[Room Acoustics guide](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/).

**Video:** [Sweep measurement and deconvolution to the impulse response](https://docs.jmrp.io/phonometry/media/anim_sweep_deconvolution.webm): An exponential sweep crosses a drawn room while the recorded spectrogram builds, with the discrete reflections appearing as delayed copies of the main ridge; the inverse filter then collapses the whole recording into the impulse response.

![Recovered room impulse response: the normalized waveform with the direct sound and reflections labelled, and below it the log-magnitude envelope in dB with the Schroeder energy-decay curve](https://docs.jmrp.io/phonometry/media/impulse_response.webp)

**Show the code for this figure**

```python
import numpy as np
from scipy.signal import fftconvolve
# `room` is the import of the main snippet above.

fs = 48000
sweep = room.sweep_signal(fs, 20.0, 20000.0, 1.5)
# A synthetic room: direct sound + two reflections + a decaying diffuse tail
system = np.zeros(int(0.7 * fs))
system[80], system[1400], system[3100] = 1.0, 0.5, 0.32
ir = room.impulse_response(fftconvolve(sweep, system), sweep, fs, length=system.size)

# One-liner: waveform + log-magnitude / Schroeder decay
ir.plot()

# By hand: the normalized log-magnitude envelope in dB
import matplotlib.pyplot as plt
h = np.asarray(ir)
t = np.arange(h.size) / fs
plt.plot(t, 20 * np.log10(np.abs(h) / np.max(np.abs(h))))
plt.ylim(-80, 5)
plt.xlabel("Time [s]"); plt.ylabel("Level re peak [dB]")
```

One thing this response is *not*: the impulse response of the room. What the
deconvolution returns is the response of **loudspeaker, room and microphone in
series**: clause A.1 of ISO 18233 says as much for the MLS chain, and the
sweep is no different. For reverberation time that is harmless, because a
fixed linear filter changes the shape of the early part but not the slope of
the band decay, which is why reverberation times transfer between measurement
systems. For the energy parameters it is not: the source's low-frequency
roll-off and its high-frequency directivity redistribute early energy and
shift C50, C80 and $T_\mathrm{S}$, so those do **not** transfer. Two consequences
follow. Quote the source used whenever you report clarity or centre time; and
remove the free-field response of the chain before auralising the response or
comparing it across systems. It is also why the standard specifies the
source's *directivity* rather than its frequency response: directivity varies
between positions and cannot be equalised away.

### `sweep_signal()` / `inverse_filter()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `fs` | int | Hz | > 0 | Sampling frequency |
| `f1` | float | Hz | > 0, at/below lowest band | Sweep start frequency |
| `f2` | float | Hz | `f1 < f2 <= fs/2` | Sweep stop frequency |
| `duration_s` | float | s | 2–4 × the longest expected T | Sweep duration; see "Dimensioning the excitation" above |
| `amplitude` | float | — | default `1.0` | Peak amplitude |
| `fade` | float | — | `[0, 0.5)`, default `0.01` | Half-Hann fade fraction (kills start/stop transients) |

`inverse_filter(fs, f1, f2, duration_s, amplitude=..., fade=...)` takes exactly
the same arguments as `sweep_signal`, because the filter is derived from the
sweep it has to invert: it is the time-reversed sweep with a +6 dB/octave
envelope, which whitens the ESS's −3 dB/octave spectrum so that convolving
sweep with filter yields an impulse (ISO 18233 B.5). You only call it yourself
to inspect the filter or to convolve a recording by hand:
`impulse_response(..., method="farina")` builds it internally from `f_range`.

### `impulse_response()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `recorded` | 1D array | any | non-empty | Recorded system response |
| `reference` | 1D array | any | non-empty | The emitted sweep |
| `fs` | int | Hz | > 0 | Sample rate |
| `method` | str | — | `'spectral'` (default) / `'farina'` | `'farina'` requires `f_range` |
| `f_range` | (float, float) | Hz | default `None` | `(f1, f2)` of the sweep (Farina only) |
| `regularization` | float | — | default `1e-6` | Tikhonov term as a fraction of peak spectral energy |
| `length` | int, optional | samples | default `len(recorded)` | Samples of causal IR to return |
| `return_full` | bool | — | default `False` | Return the full sequence (distortion in the tail) |

`mls_signal(order)` takes an integer `order` in 2–20 (sequence length
$2^{\text{order}}-1$); `mls_impulse_response(recorded, mls, length=None)`
needs `recorded` to span an integer number of MLS periods.

## The measuring chain

A deconvolved sweep is only ever as good as what radiated it, and ISO 3382-1
clause 4.2 is specific about all three parts of the chain.

**The source (4.2.1).** It "shall be as close to omnidirectional as possible",
and Table 1 sets how close, as the maximum deviation from omnidirectionality
averaged over gliding 30° arcs in a free field, measured with at least 1.5 m
between source and microphone:

| Frequency [Hz] | 125 | 250 | 500 | 1000 | 2000 | 4000 |
| :--- | :---: | :---: | :---: | :---: | :---: | :---: |
| Maximum deviation [dB] | ± 1 | ± 1 | ± 1 | ± 3 | ± 5 | ± 6 |

That is why room work uses a **dodecahedron** and why the output of
`sweep_signal` cannot simply be played through a studio monitor: a one-way
monitor is directional well before 1 kHz, and the deviation it would show at
2 and 4 kHz is tens of decibels, not 5 or 6.

**The level (4.2.1).** Without synchronous averaging, the source must give a
level **at least 45 dB above the background in the corresponding frequency
band** if T30 is to be measured, and at least **35 dB** if only T20 is needed.
The 20–30 dB of processing gain measured at the top of this page is what lets
a modest source meet that, but it cannot conjure range in a band where the
room is louder than the source. Nothing in the chain may overload (4.2.2.5).

**The receiving chain (4.2.2.2).** The equipment shall meet the requirements
of a **type 1 (class 1)** sound level meter to IEC 61672-1, with octave or
one-third-octave filters to **IEC 61260**. The microphone shall be
omnidirectional and should be as small as possible, preferably with a
diaphragm no larger than **13 mm**; up to 26 mm is allowed for a pressure-
response capsule, or a free-field capsule fitted with a random-incidence
corrector.

**The heights (4.3).** The **acoustic centre of the source should be 1.5 m**
above the floor, at positions where the room's natural sources would stand,
and with **at least two** source positions. Microphones sit at **1.2 m**,
seated-ear height, at least a quarter wavelength ("normally around 1 m")
from the nearest reflecting surface **including the floor**.

![Section through a 10 by 6 by 3.5 metre room: a dodecahedron on a stand with its acoustic centre dimensioned 1.5 metres above the floor and its 2.0 metre d_min exclusion circle clipped to the room, two microphones on stands at 1.2 metres with the 2 metre minimum spacing and the 1 metre clearances to the ceiling, the floor and the end wall, and beneath the section the ISO 3382-1 Table 1 omnidirectionality tolerances of plus or minus 1, 1, 1, 3, 5 and 6 decibels from 125 Hz to 4 kHz together with the level and receiving-chain requirements](https://docs.jmrp.io/phonometry/media/diagram_room_measurement_section.svg)

The same 45 dB is what the T30 validity flag checks downstream: the
[Room Acoustics guide](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) rejects a
band whose decay range does not clear the evaluation window by 15 dB, and that
rejection is usually a source-level problem, not a processing one.

## Where to measure

One IR characterises a single source–receiver pair; a
reported room parameter is the spatial average over several. ISO 3382-1
(performance spaces) asks for at least two source positions and microphones
spaced $\geq 2$ m apart, $\geq 1$ m from any surface, at $1.2$ m
(seated-ear) height; ISO 3382-2 fixes the minimum number of source,
microphone and source–microphone combinations per accuracy grade
(survey / engineering / precision) and asks for microphone positions that
avoid symmetric placements.

![Room-acoustics measurement setup: a top-view room plan with two loudspeaker source positions and six microphone positions with the ISO 3382-1 spacing rules, and the ISO 3382-2 table of minimum positions for the survey, engineering and precision grades](https://docs.jmrp.io/phonometry/media/diagram_room_measurement.svg)

**Averaging across positions.** The reported per-band parameter is the
arithmetic mean over all source-microphone combinations, and the spread
across positions is part of the answer, not noise: quote it alongside the
mean whenever it exceeds the parameter's JND (ISO 3382-1 Table A.1), because a room can meet a
target on average while individual seats sit far outside it.

Before the four mistakes below, one thing that is *not* a mistake: a single
floor reflection reaching the microphone alongside the direct sound comb-filters
the response, and moving the microphone moves the comb with it. That is the
mechanism behind the first two mistakes.

**Video:** [Comb filtering from a single floor reflection](https://docs.jmrp.io/phonometry/media/anim_comb_filtering.webm): Direct sound and one floor reflection reach the microphone; as the microphone height changes, the delay between the two paths shifts and the comb filter in the frequency response moves with it, which is why measurement position matters near reflecting surfaces.

Four placement mistakes bias the mean itself:

- **Correlated positions.** Microphones closer than 2 m to each other
  sample nearly the same sound field twice, so the average looks more
  stable than it is. The 1 m minimum from any surface likewise avoids the
  pressure build-up near a boundary (the comb filter of the clip above)
  that colours everything a too-close microphone records.
- **Symmetric placements.** In a geometrically symmetric room, mirror-image
  positions receive mirror-image reflection patterns; averaging them adds
  no new information. This is why ISO 3382-2 asks for positions that do not
  sit on symmetry lines.
- **Too close to the source.** Inside the direct field EDT collapses and
  C80 saturates upward no matter what the room does. ISO 3382-2 therefore
  keeps every microphone at least $d_\mathrm{min} = 2\sqrt{V/(c\,\hat T)}$ from
  the source, with $\hat T$ an estimate of the expected reverberation time
  (2.0 m for the 10 × 6 × 3.5 m room of the drawings above, V = 210 m³, with
  an expected 0.6 s).
- **Low-frequency luck.** Below the Schroeder frequency (see the
[Room Acoustics guide](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/)) each band
  holds only a handful of room modes, and a microphone on a node of one of
  them sees a different decay than a microphone on an antinode. The spread
  of the 63-125 Hz bands across positions is structurally larger; the cure
  is more positions, not a longer excitation.

The third mistake is the one worth drawing, because it does not look like a
mistake in the result:

![Two stacked panels sharing a source-receiver distance axis from 0.6 to 7 metres in the same 10 by 6 by 3.5 metre room as the setup drawings. Above, the 500 to 1000 Hz mean T30 stays between 0.53 and 0.65 seconds across the whole sweep while EDT climbs from 0.18 to about 0.45 seconds; below, clarity C80 falls from 17.6 to about 10.7 decibels. The region inside d_min = 2.0 metres is shaded as excluded and the critical distance of 1.5 metres is marked with a dotted line](https://docs.jmrp.io/phonometry/media/source_distance_bias.svg)

*EDT, T30 and C80 of the room above against source distance, from synthetic
impulse responses. Inside $d_\mathrm{min}$, EDT is short by a factor of about 2.5 and
C80 is 7 dB high, many times the 5 % relative and 1 dB just-noticeable
differences of ISO 3382-1 Table A.1, while T30 wanders by 0.12 s over the
whole sweep with no trend at the close end. That asymmetry is the trap: a
survey that reports only T30 will not notice that the microphone was too
close, and every energy parameter beside it is wrong.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
# `room` is the import of the main snippet above.

dims, alpha, source = (10.0, 6.0, 3.5), 0.32, (2.0, 3.0, 1.5)
volume = float(np.prod(dims))
print(round(2.0 * np.sqrt(volume / (343.0 * 0.6)), 1))     # 2.0 m: d_min

for dist in (0.6, 1.0, 2.0, 4.0, 7.0):
    band = []
    for offset in (-0.7, -0.25, 0.25, 0.7):   # one specular receiver scatters
        res = room.image_source_rir(
            dims, source, (2.0 + dist, 3.0 + offset, 1.2), alpha, fs=48000,
            max_order=40,      # c x 0.58 T / L_min, not the default 20
        )
        par = room.room_parameters(res.ir, res.fs, limits=(125.0, 4000.0))
        mid = (par.frequencies > 400.0) & (par.frequencies < 1200.0)
        band.append([np.mean(par.edt[mid]), np.mean(par.t30[mid]),
                     np.mean(par.c80[mid])])
    print(dist, np.round(np.mean(band, axis=0), 2))
# 0.6 [ 0.18  0.53 17.56]  ...  7.0 [ 0.45  0.65 10.72]
plt.show()
```

And the fourth is worth counting. The Schroeder frequency is where a room
stops being a handful of resonances and starts being a statistical field, and
the count is stark:

![Bar chart on logarithmic axes of the number of room modes inside each octave band from 63 Hz to 4 kHz for a 7 by 5 by 3 metre room of 105 cubic metres: 13 modes at 63 Hz and 77 at 125 Hz, both below the marked Schroeder frequency of 185 Hz, rising to 514 at 250 Hz, 28412 at 1 kHz and 1749162 at 4 kHz](https://docs.jmrp.io/phonometry/media/modal_count_per_band.svg)

*Why "more positions, not a longer excitation". The 4 kHz octave of this room
contains about 1.75 million modes, so the band average does the spatial
averaging for you and every microphone reports nearly the same decay. The
63 Hz octave contains **13**: which of them a given microphone sits on decides
what it measures, and only more microphones can average that out. A longer
sweep buys signal-to-noise ratio, which is a different problem.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
# `room` is the import of the main snippet above.

dims, reverberation = (7.0, 5.0, 3.0), 0.9
bands = np.array([63.0, 125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0])
edge = np.sqrt(2.0)
counts = [room.room_mode_count(dims, frequency=f * edge) - room.room_mode_count(dims, frequency=f / edge)
          for f in bands]
print([round(c) for c in counts])
# [13, 77, 514, 3735, 28412, 221512, 1749162]
print(round(room.schroeder_frequency(reverberation, float(np.prod(dims)))))   # 185

plt.bar(bands, counts, width=bands * 0.62)
plt.xscale("log"); plt.yscale("log")
plt.show()
```

**The room while you measure it.** ISO 3382-2 clause 4.1: reverberation-time
measurements "should be made in a room containing no people", though **up to
two persons** may be present and still represent the unoccupied state unless
the specification says otherwise. If the result will be used to correct a
level measurement, freeze the occupancy: the same number of people must be
present for both. For **precision** measurements the temperature and relative
humidity in the room shall normally be measured: both because the standard
requires it and because they set the air-absorption term the prediction guides
consume. The exception is stated too: air absorption is negligible when $T$ is
shorter than 1.5 s at 2 kHz and 0.8 s at 4 kHz, and then the climate need not
be recorded.

**The rotating boom.** Clause 4.3.1 allows a moving microphone in place of
discrete positions, with three constraints: a sweep radius of at least
**0.7 m**, a traverse plane **at least 10° off every plane of the room** (wall,
floor, ceiling), and a traverse period of **at least 15 s**. It substitutes
for multiple microphone positions only where the Table 1 grade allows it: for
the interrupted-noise method, and where the result is a correction term.

**What the report must carry (clause 9.2).** A statement of conformity with
ISO 3382-2; enough to identify the room uniquely; a **scaled sketch plan**;
the volume; the condition of the room (furniture, people present); for the
precision method, the temperature and relative humidity; the type of source
and a description of the signal; the **degree of precision** (survey,
engineering or precision) with the source and microphone positions,
preferably shown on that plan together with their heights; the measuring
apparatus and microphones; the evaluation method for the decay curves; how the
result was averaged in each position and over positions; the results table;
and the date and the measuring organisation. The fiche of the
[Room Acoustics guide](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) carries
most of these as `ReportMetadata` fields, but the scaled plan with the
positions on it has to be supplied alongside it.

## From the impulse response onward

The IR leaves this page in several directions. Band-filtered and
backward-integrated it becomes the decay curve whose slope is the
reverberation time: the
[Room Acoustics guide](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) picks up exactly
there, and its open-plan sibling walks the
[ISO 3382-3 line of workstations](https://docs.jmrp.io/phonometry/buildings/rooms/open-plan-acoustics/).
Measured either side of a partition, the same sweeps feed the level
differences of
[field sound insulation](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/). And the
harmonic distortion that the exponential sweep pushes to negative arrival
times is not always discarded: read deliberately, it becomes the THD
analysis of the
[swept-sine distortion guide](https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/).

## What this guide covers

- **Covered.** ISO 18233:2006's deterministic acquisition of the room impulse response: the
  Annex B exponential sine sweep (`room.sweep_signal`, `room.inverse_filter`)
  with linear spectral deconvolution (Tikhonov-regularized) and the Farina
  inverse-filter variant (`room.impulse_response`, methods `"spectral"` and
  `"farina"`), and the Annex A maximum-length sequences (`room.mls_signal`,
  orders 2-20, `room.mls_impulse_response` by circular cross-correlation). The
  results are `ImpulseResponseResult` objects that drop into
  `room.room_parameters` unchanged. The ISO 18233 sizing rules (clause B.3.1
  sweep length and silence, clause 6.2.2.2 Eq. (10) for the MLS period), the ISO
  3382-1 clause 4.2 equipment requirements and the ISO 3382-1/-2 placement rules
  (spacing, surface distance, the minimum source distance, the rotating-boom
  alternative and the accuracy grades) are quoted for planning, together with
  the clause 9.2 report checklist.

- **Not covered.** Playback and recording themselves (sound-card I/O, level calibration of the
  chain) are outside the library. ISO 18233's time-variance and distortion
  diagnostics are not implemented: the guide explains how the sweep separates
  distortion, but no helper quantifies it (that reading lives in the [swept-sine
  distortion
  guide](https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/)). The
  position rules are guidance prose: nothing checks how many positions were
  measured or where.

## See also

- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the decay analysis
  and ISO 3382 parameters computed from the IR this page acquires.
- [Open-Plan Office Acoustics (ISO 3382-3)](https://docs.jmrp.io/phonometry/buildings/rooms/open-plan-acoustics/):
  the speech-privacy line measured with the same acquisition.
- [System Measurement](https://docs.jmrp.io/phonometry/signals/spectra/system-measurement/):
  complementary Golay pairs and spectrally shaped sweeps, returning the same
  result types.
- [Swept-Sine Distortion & Phase](https://docs.jmrp.io/phonometry/devices/electroacoustics/swept-sine-distortion/):
  the Farina reading of the distortion the sweep separates.
- [Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/):
  the same measurement either side of a partition.
- [Image Sources & Steady-State Field](https://docs.jmrp.io/phonometry/buildings/rooms/room-image-sources/):
  simulated impulse responses to rehearse the processing chain on.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/): the Schroeder
  integration the decay analysis applies to this IR.
- [Conformance report](https://docs.jmrp.io/phonometry/reference/conformance/):
  the closed-form deconvolution check this acquisition is validated against, a
  sweep that recovers a known response.
- API reference: [`room`: impulse response](https://docs.jmrp.io/phonometry/reference/api/rooms/impulse-response/).
- Theory: [Impulse response and room-acoustic parameters](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/#impulse-response-and-room-acoustic-parameters-iso-18233-iso-3382-1-2-3): the Schroeder backward integration and the deconvolution the sweep method rests on.

## Quick answers

### Should I measure the room impulse response with a sine sweep or an MLS?

Both are ISO 18233 deconvolution methods that recover the impulse response with 20–30 dB more effective signal-to-noise ratio than an impulsive source. Prefer the exponential sine sweep (Annex B): it places harmonic distortion at negative arrival times, where it is discarded. Use MLS (Annex A) when the excitation must be periodic or the hardware favours a two-level signal; it is more sensitive to time variance.

## References

- **International Organization for Standardization. (2006).** [*Acoustics — Application of new measurement methods in building and room acoustics*](https://www.iso.org/standard/40408.html) (ISO 18233:2006).
  The swept-sine and MLS acquisition this page implements.
- **International Organization for Standardization. (2008).** [*Acoustics — Measurement of room acoustic parameters — Part 2: Reverberation time in ordinary rooms*](https://www.iso.org/standard/36201.html) (ISO 3382-2:2008).
  The accuracy grades, position counts and the minimum source distance behind the position-averaging discussion.
- **International Organization for Standardization. (2009).** [*Acoustics — Measurement of room acoustic parameters — Part 1: Performance spaces*](https://www.iso.org/standard/40979.html) (ISO 3382-1:2009).
  The source and microphone position requirements quoted in the where-to-measure rules.