# Reporting and source qualification (ISO 3382-1)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/rooms/reporting-and-qualification/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/rooms/reporting-and-qualification/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-09-06
Updated: 2026-11-16T21:36:14Z
Standards: ISO 3382-1:2009
Verified: 22 conformance checks (ISO 3382-1:2009) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Printed tables of ISO 3382-1: source directivity, how many microphone positions a hall needs, the bands of each single number, and the report.

---

Most of ISO 3382-1 is about how to measure. This page is about the four
tables it prints and the rules that go with them: what a source has to be
before it may be used, how many seats a survey has to reach, how the bands
are averaged into the one number a hall gets quoted by, and what the report
shall say.

## 1. Qualifying the source

A source that is not omnidirectional measures a different hall depending on
which way it faces. Table 1 says how far from omnidirectional it may be,
band by band, and 4.2.1 says how to find out.

![Three panels. Left: a polar plot of a source measured every 5 degrees, nearly round at 125 Hz and strongly lobed at 4 kHz. Middle: the deviation of each gliding 30 degree arc from the whole-turn average against bearing, with the Table 1 limits of plus and minus 1 dB and plus and minus 6 dB drawn as dashed lines; the 125 Hz survey stays well inside its limit and the 4 kHz one dips past its own. Right: a grid of the seven Table A.1 quantities against the six octave bands, shading the bands each single number averages, two for five of them and four for the other two, with the late lateral level's row in a different colour because it alone is energy averaged](https://docs.jmrp.io/phonometry/media/directivity_and_tables.svg)

*A source qualifies at 125 Hz and fails at 4 kHz, and Table A.1 does not
average every quantity over the same bands.*

The survey is made on a turntable, or from measurements every 5 degrees if
there is none. Either way the readings are combined into **gliding 30 degree
arcs**, and each arc is compared with a reference that is "a 360 degree
energetic average in the measurement plane". Source and microphone are at
least 1.5 m apart throughout.

```python
import numpy as np
from phonometry import room

bearings = np.arange(72) * room.DIRECTIVITY_STEP_DEG
pattern = 7.5 * np.cos(8.0 * np.deg2rad(bearings))
pattern += 2.4 * np.cos(16.0 * np.deg2rad(bearings))

deviation = room.gliding_directivity_deviation(94.0 + pattern)
print(round(float(np.max(np.abs(deviation))), 2))   # 6.89  dB
print(room.source_directivity_limit(4000.0))        # 6.0   dB
```

Table 1 prints six bands, 125 Hz to 4 kHz, and no more, so a survey in the
63 Hz or 8 kHz octave has no printed limit to be held to rather than the
nearest one:

```python
from phonometry import room

print(room.MAX_SOURCE_DIRECTIVITY_DEVIATION_DB)
# {125.0: 1.0, 250.0: 1.0, 500.0: 1.0, 1000.0: 3.0, 2000.0: 5.0, 4000.0: 6.0}
```

**Two things about that survey are not settled by what is printed.** The
first is a contradiction: 4.2.1 and the caption of Table 1 both call its
values the *maximum* acceptable deviation, and A.4 calls them "the minimum
limits given in Table 1" when it asks for a marginal source to be measured
again at three orientations. Read literally, A.4 asks for the extra work on
the sources that need it least. The second is an omission: "gliding
averages, each covering six neighbouring points" does not say whether the
six lead, trail or straddle the arc they are reported against. Over a full
turn that is a relabelling, so it moves the bearing each deviation is
reported against by up to 15 degrees of the pattern and not the deviation
itself, but the bearing is what A.4 asks a marginal source to be turned
about. Both are in
[the errata register](https://docs.jmrp.io/phonometry/reference/errata/), and
`gliding_directivity_deviation` says in its docstring which readings it took.

## 2. How many positions, and where

Table A.2 prints three rows: 500 seats want 6 microphone positions, 1 000
want 8 and 2 000 want 10. They lie exactly on a straight line in the
logarithm of the seat count, two positions per doubling, which is what lets
a hall between the rows be answered at all.

```python
from phonometry import room

print([round(float(room.min_receiver_positions(n)), 2)
       for n in (500, 1000, 1400, 2000)])
# [6.0, 8.0, 8.97, 10.0]
print(round(float(room.min_receiver_positions(5000)), 2))   # 10.0
```

The line stops where the table does. A.4 asks for "a minimum of between 6
and 10 representative microphone positions", so a 5 000-seat arena does not
get thirteen positions on the strength of three rows, and a 200-seat studio
does not get four. A.4 adds the geometry the table does not: at least three
on-stage source positions in the normal case, a source height of 1.5 m, a
microphone height of 1.2 m at audience seat locations, positions evenly
distributed over all the seating, and more of them wherever a hall breaks
into balconies and under-balcony areas.

![Two halves. Left, seen from above: a source in a free field on a turntable, and around it the seventy-two bearings of the survey made every 5 degrees where no turntable can be used, with a microphone on that ring at least one and a half metres from the acoustic centre. Six neighbouring readings are picked out as one gliding 30 degree arc, an arrow shows the next arc starting one reading on, and every arc is compared with the 360 degree energetic average in the measurement plane. Under it, Table 1 for octave bands of pink noise: plus or minus 1 dB at 125, 250 and 500 Hz, 3 dB at 1 kHz, 5 dB at 2 kHz and 6 dB at 4 kHz. Right: the plan of a 1 000-seat hall with three source positions on the stage, one on the centre line and one either side of it, eight microphone positions, the fewest Table A.2 asks for at that size, spread over the seating on one side of the centre line, and two more under the balcony, and below the plan a section with the source one and a half metres above the stage floor and a microphone one point two metres above the floor beside a seated listener. Two boxes at the foot carry the deviation of an arc from the reference, and the minimum number of microphone positions as a line through Table A.2, 6 for 500 seats, 8 for 1 000 and 10 for 2 000, kept between 6 and 10](https://docs.jmrp.io/phonometry/media/diagram_source_qualification.svg)

### How the measurement goes

Qualify the source first. Drive it with octave bands of pink noise in a free
field and keep the microphone at least 1.5 m away. On a turntable, average its
output over gliding 30 degree arcs; without one, take a reading every
5 degrees and average six neighbouring readings into each arc. Every arc is
then held against the 360 degree energetic average in the measurement plane:
from 125 Hz to 4 kHz, none of them may leave Table 1.

Measure with a type 1 instrument to IEC 61672-1, IEC 61260 filters and an
omnidirectional microphone, preferably with a diaphragm no more than 13 mm
across, its sensitivity calibrated if $G$ is wanted. Normally use at least
three source positions on the stage, more with a large stage or an orchestra
pit, for instance one on the centre line and two at equal distances either
side, with the acoustic centre 1.5 m above the floor. Take the minimum number
of microphone positions from Table A.2, 6 for 500 seats up to 10 for 2 000, at
1.2 m above the floor at seats, about 2 m apart at least, spread evenly, and
add more where balconies split the seating. Without synchronous averaging,
hold the source at least 45 dB over the background in every band, or at least
35 dB when only $T_{20}$ is wanted, and average repeats of any response that
does not repeat exactly. Measure a source close to its Table 1 limits again,
turned in at least three steps, and average arithmetically. Report the source
and microphone positions with their heights, preferably on a plan, the stage
furnishing and the occupancy, and the rest of the fifteen items of 9.2.

## 3. The single number, and the two exceptions in it

Every quantity in Annex A gets quoted as one number, and A.5 asks for the
index "m" on the symbol when it is. What the "m" averages is **not** the
same for every quantity: Table A.1 gives each row its own band set, and A.5
prints two examples for exactly that reason, $G_\mathrm{m}$ over the 500 Hz and 1 kHz
octaves and $J_\mathrm{LFm}$ over four bands from 125 Hz.

```python
import numpy as np
from phonometry import room

octaves = np.array([125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0])
strength = np.array([6.2, 5.4, 4.8, 4.4, 4.1, 3.6])
lateral = np.array([0.20, 0.26, 0.31, 0.28, 0.24, 0.19])

print(round(room.single_number_average("G", strength, frequencies=octaves), 4))    # 4.6
print(round(room.single_number_average("J_LF", lateral, frequencies=octaves), 4))  # 0.2625
print(room.TABLE_A1["G"].averaging_bands_hz)      # (500.0, 1000.0)
print(room.TABLE_A1["J_LF"].averaging_bands_hz)   # (125.0, 250.0, 500.0, 1000.0)
```

One of the seven rows carries two symbols. The table prints the early
lateral energy fraction as "$J_{\mathrm{LF}}$ or $J_{\mathrm{LFC}}$", one
row for the two weightings of Equations (A.14) and (A.15), so
`"J_LFC"` is taken wherever `"J_LF"` is and reads the same
four bands, the same just-noticeable difference and the same range.

```python
import numpy as np
from phonometry import room

octaves = np.array([125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0])
lateral = np.array([0.20, 0.26, 0.31, 0.28, 0.24, 0.19])

print(round(room.single_number_average("J_LFC", lateral, frequencies=octaves), 4))  # 0.2625
print(room.assess_perceptible_difference("J_LFC", 0.20, 0.26).different)                  # True
```

Footnote a of the table makes one row an exception to the arithmetic: the
late lateral sound level is **energy** averaged, through Equation (A.17).
And two of its just-noticeable differences are not plain numbers either.
The early decay time's is printed as "Rel. 5 %", a fraction of the value
rather than a difference in seconds, so the same 60 ms means nothing in a
two-second hall and is plain in a half-second one. The late lateral level's
is printed as "Not known", and the library refuses to invent one.

```python
from phonometry import room

print(room.assess_perceptible_difference("EDT", 2.0, 2.06).different)    # False
print(room.assess_perceptible_difference("EDT", 0.5, 0.56).different)    # True
print(room.TABLE_A1["L_J"].just_noticeable_difference) # None
```

A.5 also offers a coarser presentation, the octave **pairs**: 125 Hz with
250 Hz for a low-frequency result, 500 Hz with 1 kHz for a mid one, and
2 kHz with 4 kHz for a high one, all arithmetic. That is a different product
from the single number and the two must not share a code path: they are the
same two bands for the five monaural quantities and different band sets for
the lateral ones.

```python
import numpy as np
from phonometry import room

octaves = np.array([125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0])
lateral = np.array([0.20, 0.26, 0.31, 0.28, 0.24, 0.19])

pairs = room.octave_pair_averages(lateral, frequencies=octaves)
print({k: round(v, 4) for k, v in pairs.items()})
# {'low': 0.23, 'mid': 0.295, 'high': 0.215}
print(round(room.single_number_average("J_LF", lateral, frequencies=octaves), 4))  # 0.2625
```

A.5 notes that lateral energy fractions in the 4 kHz octave are not usually
thought to be subjectively important, so the high pair means little for
them.

## 4. Two routes to a mid-frequency reverberation time

Clause 9.1 prints two ways to quote one number for the reverberation time
and no third: the average of $T_{30}$ over the 500 Hz and 1 kHz **octave**
bands, or "averages over the six one-third-octave bands from 400 Hz to
1 250 Hz".

```python
from phonometry import room

print(room.MID_FREQUENCY_OCTAVES_HZ)
# (500.0, 1000.0)
print(room.MID_FREQUENCY_THIRD_OCTAVES_HZ)
# (400.0, 500.0, 630.0, 800.0, 1000.0, 1250.0)
```

What a one-third-octave analysis must not do is average the two
one-third-octave bands that happen to be called 500 Hz and 1 kHz. That is
two thirds of an octave against the two octaves either printed route covers,
a third of the band, and it is neither of them. The
[accredited fiche](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) takes the
six-band route when the analysis is in thirds and names it on the sheet.

## 5. What the report shall say

Clause 9 is normative, unlike every annex on this page, and 9.2 is its only
requirement about what is written down rather than what is measured. It
lists fifteen items, a) to o), and `TEST_REPORT_ITEMS` carries them in
order: the conformity statement, the room's name, place, plan and volume,
its seating and upholstery, the shape and material of walls and ceiling, the
occupancy, the state of any variable equipment, the curtains in a theatre,
the stage furnishing, the temperature and humidity, the apparatus, the
signal, the coverage with its positions and heights, and the date and the
organization.

```python
from phonometry import room

print(len(room.TEST_REPORT_ITEMS))     # 15
print(room.TEST_REPORT_ITEMS[3])
# volume of the room, with an explanation of how it is defined if the room
# is not completely enclosed
```

Most of that is metadata rather than measurement, and it reaches the
accredited fiche through the `ReportMetadata` container the
[room acoustic parameters page](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/)
fills in.

## What this guide covers

- **Covered.** The printed tables of ISO 3382-1:2009 and the rules around them: Table 1 with
  the gliding arc survey of 4.2.1, Table A.1 with its per-quantity averaging
  bands, its one energy-averaged row and its one relative just-noticeable
  difference, Table A.2 with the line its three rows lie on, the octave pairs of
  A.5, the two single-number routes of Clause 9.1, and the fifteen items
  Clause 9.2 says a test report shall include. The
  [conformance report](https://docs.jmrp.io/phonometry/reference/conformance/) holds Table A.1 and its
  footnote, Table A.2, the 4.2.1 survey and the Clause 9.1 bands against the
  printed text.

- **Not covered yet.** The procedures around them: the three-orientation repeat A.4 asks of a source
  close to its Table 1 limits, the sectional averaging A.5 suggests for a large
  hall, and the plotting conventions of Clause 9.1, which are about paper rather
  than about numbers.

## See also

- [Room Acoustic Parameters](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the
  decay analysis these tables report the results of, and the accredited fiche.
- [Sound Strength G](https://docs.jmrp.io/phonometry/buildings/rooms/sound-strength/),
  [Spatial Impression](https://docs.jmrp.io/phonometry/buildings/rooms/spatial-impression/) and
  [Stage Support and Uncertainty](https://docs.jmrp.io/phonometry/buildings/rooms/stage-and-uncertainty/):
  the quantities Table A.1 averages.
- API reference: [`room.auditorium`](https://docs.jmrp.io/phonometry/reference/api/rooms/auditorium/).

## References

- **Bradley, J. S. (2011).** Review of objective room acoustics measures and future needs. *Applied Acoustics*, *72*(10), 713-720. https://doi.org/10.1016/j.apacoust.2011.04.004
  A review of what the Table A.1 quantities are for and how their just-noticeable differences came about.
- **International Electrotechnical Commission. (2014).** [*Electroacoustics — Octave-band and fractional-octave-band filters — Part 1: Specifications*](https://webstore.iec.ch/en/publication/5063) (IEC 61260-1:2014).
  The band centres every average on this page is taken over.
- **International Organization for Standardization. (2009).** [*Acoustics — Measurement of room acoustic parameters — Part 1: Performance spaces*](https://www.iso.org/standard/40979.html) (ISO 3382-1:2009).
  Table 1 and 4.2.1, Table A.1, Table A.2 with A.4, A.5 and Clause 9: the tables and the reporting rules of this page.
- **Witew, I. B., Behler, G. K., & Vorländer, M. (2017).** About just noticeable differences for aspects of spatial impressions in concert halls. *Acoustics Australia*, *45*(2), 195-202. https://doi.org/10.1007/s40857-017-0094-7
  Why Table A.1 prints no just-noticeable difference for the late lateral sound level.