# Open-Plan Office Acoustics (ISO 3382-3)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/rooms/open-plan-acoustics/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/rooms/open-plan-acoustics/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-28
Updated: 2026-11-16T21:36:10Z
Standards: ISO 3382-3:2012
Verified: 1 conformance checks (ISO 3382-3:2012) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Open-plan office speech privacy (ISO 3382-3): D2,S, level at 4 m, distraction and privacy distances, the fiche and Long's occupant-noise prediction.

---

An open-plan office is not a reverberation problem; it is a privacy
problem, and a room that flatters the closed-room parameters can still fail
it. ISO 3382-3 therefore characterises the office with four single numbers:
$r_\mathrm{D}$, $D_\mathrm{2,S}$, $L_{p,\mathrm{A,S},4\,\mathrm{m}}$ and the average background noise
$L_{p,\mathrm{A,B}}$ (measured along a line of workstations, walking away from a
talker). This guide covers that measurement chain: the quantities, the to-scale
measurement line and the accredited fiche. Then it turns the question
round: at design time, before any office or restaurant exists, Long's crowd
self-noise model predicts the background an occupied room generates from its
own occupants, and converts a target speech-to-noise ratio into an absorption
area per table. Measurement first, design second; the two halves share
nothing but the room. The impulse responses and levels
behind it are acquired as in
[Measuring the Room Impulse Response](https://docs.jmrp.io/phonometry/buildings/rooms/room-impulse-response/);
the per-position STI comes from the
[Speech Transmission Index guide](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/);
the closed-room decay parameters live in
[Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/).

## Speech privacy along a line of workstations

Open-plan acoustics are about **speech privacy**: how fast a talker's speech
fades to unintelligibility as you walk away. Levels and STI are measured
along a line of workstations (at least 4 positions, 6–10 preferred), and
four single-number quantities summarise the room: the distraction distance
$r_\mathrm{D}$, the spatial decay rate $D_\mathrm{2,S}$, the speech level at 4 m
$L_{p,\mathrm{A,S},4\,\mathrm{m}}$ and the average A-weighted background noise $L_{p,\mathrm{A,B}}$
(Clause 6.4). The privacy distance $r_\mathrm{P}$ and the STI at the nearest workstation
are optional additions; `open_plan_metrics` returns $D_\mathrm{2,S}$,
$L_{p,\mathrm{A,S},4\,\mathrm{m}}$, $r_\mathrm{D}$ and $r_\mathrm{P}$. The **spatial decay
rate** of A-weighted speech is the slope of the level against
$\log_{10}(r/r_0)$, scaled to a per-doubling figure using only the 2–16 m
positions,

$$
D_\mathrm{2,S} = -\log_{10}(2)\ b, \qquad L = a + b\ \log_{10}(r/r_0),\ r_0 = 1\ \text{m},
$$

with **$L_{p,\mathrm{A,S},4\,\mathrm{m}}$** read off the same line at 4 m. The **distraction
distance** $r_\mathrm{D}$ (STI = 0.50) and **privacy distance** $r_\mathrm{P}$ (STI = 0.20) come
from a linear regression of STI against distance.

Both distances are read **off the fitted line**, and clause 6.3 allows the
reading to fall outside the measured span (Figure 3 b) draws the line
extended to the crossing). So an $r_\mathrm{D}$ that lands inside the line is a
measurement, while an $r_\mathrm{P}$ well beyond the last position is an
extrapolation whose confidence decays with distance: quote it with the
measured span alongside ("$r_\mathrm{P}$ = 17 m, extrapolated from positions to 16 m").
The standard also anticipates offices where the STI never falls to 0.20
("it can prove impossible to determine the privacy distance if STI > 0,20 in
all positions"), and that is what a `nan` means here, not a bug. A
*non-decreasing* STI along the line usually means the last position sat near a
reflecting wall, where both level and STI rise; clause 6.2 says to discard
that position from the $D_\mathrm{2,S}$ and $r_\mathrm{D}$ fits rather than to puzzle over it.

ISO 3382-3 Annex A is informative, but it fixes the two ends of the scale:

| Quantity | Typical poor office | Good target |
| :--- | :---: | :---: |
| $D_\mathrm{2,S}$ | < 5 dB | ≥ 7 dB |
| $L_{p,\mathrm{A,S},4\,\mathrm{m}}$ | > 50 dB | ≤ 48 dB |
| $r_\mathrm{D}$ | > 10 m | ≤ 5 m |

Those ranges are informative, and national guidance or the client brief
overrides them. Read $D_\mathrm{2,S}$ and $L_{p,\mathrm{A,S},4\,\mathrm{m}}$ **as a pair**: the decay rate
is a slope and the 4 m level is its offset, so quoting either alone flatters or
condemns the room.

$L_{p,\mathrm{A,B}}$ is the fourth required quantity and it is not decoration: the
background noise is measured in octave bands at every position with the same
$\ge 10$ s integration, A-weighted, and averaged over the line, and that
average is the masker the per-position STI is computed against. Spatially
averaging it is what keeps $r_\mathrm{D}$ and $r_\mathrm{P}$ unambiguous. It is also why
open-plan design has two levers rather than one: **attenuation** (screens, an
absorptive ceiling, layout: these raise $D_\mathrm{2,S}$ and lower $L_{p,\mathrm{A,S},4\,\mathrm{m}}$) and
**masking** (raising the background so speech loses intelligibility sooner).
This is why the office is measured furnished, unoccupied and with the services
running. An office measured with the ventilation or the masking system turned
down returns a higher STI at every position and pushes both distances outward
by metres with nothing having changed in the room.

![ISO 3382-3 open-plan measurement line from the source at 1 m along positions from 2 m to 16 m, feeding the four quantities open_plan_metrics returns, D2,S, Lp,A,S,4m, rD and rP, with a note that Clause 4 also requires the average A-weighted background noise Lp,A,B](https://docs.jmrp.io/phonometry/media/diagram_open_plan.svg)

```python
import numpy as np
from phonometry import room

# A stand-in line: the levels are built to a clean 7 dB per doubling and the
# STI to a straight -0.03 per metre, so every printed number can be checked
# by hand. A measured line is not this tidy (see below).
r = np.array([2.0, 4.0, 6.0, 8.0, 12.0, 16.0])       # distances from the talker (m)
lp = 65.0 - 7.0 * np.log2(r)                          # A-weighted speech level (dB)
sti = 0.70 - 0.03 * r                                 # STI per position

m = room.open_plan_metrics(r, lp, sti)
print(round(m.d2s, 1), round(m.lp_as_4m, 1))         # 7.0 dB, 51.0 dB
print(round(m.rd, 1), round(m.rp, 1))                # 6.7 m, 16.7 m
m.plot()   # the spatial-decay regression of the figure below
```

**Reading this office.** $D_\mathrm{2,S}$ = 7.0 dB is exactly the Annex A good-office
threshold, but $L_{p,\mathrm{A,S},4\,\mathrm{m}}$ = 51.0 dB is above the 50 dB *poor* line, and
$r_\mathrm{D}$ still lands at 6.7 m. It is a good decay rate spent from too high a
starting level, so the fix is attenuation **near the talker** (a screen, an
absorptive ceiling raft over the workstation), rather than more decay further
out. A measured line does not look like this one: positions scatter about the
fitted line, typically by one to two decibels, with the near ones pulled up by
the direct field and the far ones flattened by the background floor. What is
reported is the **regression**, not any single position: $L_{p,\mathrm{A,S},4\,\mathrm{m}}$ is read
off the line even when no microphone stood at 4 m. This is also why six
positions are preferred: four barely constrain a slope once one of them has to
be discarded.

![Open-plan spatial decay: A-weighted speech level and STI against source distance on a log axis, with the D2,S regression, the Lp,A,S,4m marker at 4 m and the rD and rP distance crossings](https://docs.jmrp.io/phonometry/media/open_plan_decay.svg)

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import room

r = np.array([2.0, 4.0, 6.0, 8.0, 12.0, 16.0])       # distances from the talker (m)
lp = 65.0 - 7.0 * np.log2(r)                          # A-weighted speech level (dB)
sti = 0.70 - 0.03 * r                                 # STI per position
m = room.open_plan_metrics(r, lp, sti)

# One line: the D2,S regression rebuilt from the result fields, with the
# rD / rP crossings marked (the figure above adds the measured points and
# the STI axis on top of it):
m.plot()
plt.show()
```

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import room

r = np.array([2.0, 4.0, 6.0, 8.0, 12.0, 16.0])       # distances from the talker (m)
lp = 65.0 - 7.0 * np.log2(r)                          # A-weighted speech level (dB)
sti = 0.70 - 0.03 * r                                 # STI per position
m = room.open_plan_metrics(r, lp, sti)

# Spatial decay: measured Lp,A,S vs distance on a log axis, the D2,S
# regression rebuilt from the result fields, and STI with the rD / rP
# crossings on a twin axis:
b = -m.d2s / np.log10(2.0)                 # regression slope vs lg(r)
a = m.lp_as_4m - b * np.log10(4.0)         # intercept from the 4 m level
rr = np.logspace(np.log10(2.0), np.log10(16.0), 100)

fig, ax = plt.subplots()
ax.semilogx(r, lp, "o", label="Measured Lp,A,S")
ax.semilogx(rr, a + b * np.log10(rr), "--", label=f"D2,S = {m.d2s:.1f} dB")
ax.plot(4.0, m.lp_as_4m, "D", label=f"Lp,A,S,4m = {m.lp_as_4m:.0f} dB")
ax.set_xlabel("Distance from the talker r [m]")
ax.set_ylabel("A-weighted speech level [dB]")
ax.set_xlim(1.8, 20.0)

twin = ax.twinx()
twin.semilogx(r, sti, "s-", color="#2ca02c", label="STI")
twin.axvline(m.rd, ls=":", color="#2ca02c")
twin.axvline(m.rp, ls=":", color="#9467bd")
twin.annotate(f"rD = {m.rd:.1f} m", (m.rd, 0.52))
twin.annotate(f"rP = {m.rp:.1f} m", (m.rp, 0.22))
twin.set_ylabel("STI")
twin.set_ylim(0.0, 1.0)

lines, labels = ax.get_legend_handles_labels()
tl, tlab = twin.get_legend_handles_labels()
ax.legend(lines + tl, labels + tlab, loc="best")
plt.show()
```

Against the Annex A scale, that one office sits between two very different
rooms:

![Two stacked panels on a shared logarithmic distance axis from 2 to 16 metres. Above, the A-weighted speech level of a treated office decaying at 8 dB per doubling through 47 dB at 4 metres and of an untreated one at 4 dB per doubling through 52 dB, with the Annex A bands shaded: above 50 dB poor, at or below 48 dB the good target. Below, the two STI regressions crossing 0.50 at 4.5 and 11.0 metres, with the good band up to 5 metres and the poor band beyond 10 metres shaded and the STI = 0.20 privacy line marked](https://docs.jmrp.io/phonometry/media/open_plan_quality.svg)

*The two ends of Annex A on one axis. The treated office meets all three
targets; the untreated one misses all three, and its privacy distance, 24 m
read off a 16 m line, is exactly the extrapolation warned about above.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
# `room` is the import of the first snippet above.

positions = np.array([2.0, 3.0, 4.0, 6.0, 8.0, 11.0, 16.0])
for d2s, lp_4m, sti_0, sti_slope in ((8.0, 47.0, 0.62, 0.0267),
                                     (4.0, 52.0, 0.75, 0.0227)):
    slope = -d2s / np.log10(2.0)
    levels = (lp_4m - slope * np.log10(4.0)) + slope * np.log10(positions)
    res = room.open_plan_metrics(positions, levels, sti_0 - sti_slope * positions)
    print(round(res.d2s, 1), round(res.lp_as_4m, 1),
          round(res.rd, 1), round(res.rp, 1))
    # 8.0 47.0 4.5 15.7   /   4.0 52.0 11.0 24.2
    plt.semilogx(positions, levels, "o--")
plt.show()
```

The line itself is worth a to-scale plan. `plot_open_plan_geometry` draws the
source, the microphone line across the workstations and the two distances on
the axis, and a result that retained its positions redraws its own line with
`m.plot_geometry()`.

![To-scale plan of the open-plan measurement line: the red source star at the origin, six blue microphone dots from 2 m to 16 m on a dotted line through the grey workstation blocks, the dashed distraction distance rD = 6.5 m and privacy distance rP = 13 m marked across the line and the 16 m span dimensioned](https://docs.jmrp.io/phonometry/media/open_plan_line_geometry.svg)

*Every ISO 3382-3 quantity comes off this one line: six microphones from 2 m
to 16 m through the workstations, with $r_\mathrm{D}$ and $r_\mathrm{P}$ landing between them.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import room

# The 2-16 m line of the example, with the distraction and privacy
# distances marked on the axis.
room.plot_open_plan_geometry([2.0, 4.0, 6.0, 8.0, 12.0, 16.0],
                             rd=6.5, rp=13.0)
plt.show()

# A result retains its positions, so m.plot_geometry() draws its own
# line with the regressed rD and rP.
```

## Measuring the line

Clauses 5.1 and 5.2 fix everything the drawing above leaves implicit.

**The source (5.1.1).** An **omnidirectional** loudspeaker radiating **pink
noise**, meeting the omnidirectionality requirements of ISO 3382-1 (the
standard is explicit about why: people in an open-plan office do not
continuously speak in any fixed direction). A deterministic pink-spectrum
signal (an MLS or a sweep, acquired as in the
[room impulse response guide](https://docs.jmrp.io/phonometry/buildings/rooms/room-impulse-response/))
is an accepted substitute, and the results are derived from the impulse
response. Its sound power is verified as in ISO 3382-1, with the source at
1.2 m, and clause 6.2 sets the level: high enough in each octave band that the
pink noise exceeds the background by **6 dB at the most distant position**.

**The receiving chain (5.1.2).** A sound level meter meeting IEC 61672-1
**class 1**, an **omnidirectional** microphone (including whatever is attached
to it), and octave filters to **IEC 61260**. If the signal is recorded for
off-line processing, the whole chain has to comply.

**The room condition (5.2.1).** Measured **furnished**, with nobody present
but the operators, and with the HVAC and any **sound-masking system running at
the power of a typical working day**. The standard states the failure directly:
if the sources run at reduced power the STI values come out too high, which
overestimates both $r_\mathrm{D}$ and $r_\mathrm{P}$. Because people are absent, the masking that
real conversation provides is not in the measurement either. The actual
distances in use are *shorter* than the measured ones.

**The line (5.2.2).** It crosses the workstations and **need not be straight**.
**6 to 10** successive positions are preferred and **4** is the minimum, with
the first at the **nearest workstation**. Source and microphone both stand at
head height in a workstation, **1.2 m** above the floor (standing working
positions are out of scope), and at least **0.5 m from tables** and **2.0 m
from walls and other reflecting surfaces**. **At least two source positions**
are used; if only one line is possible, it is measured with two sources firing
in opposite directions. Where the ceiling or the furniture changes, the office
is treated as separate **zones**, each with its own set of single numbers.

**What is recorded at each point (5.2.3).** Four things: the octave-band
pink-noise level, the STI, the octave-band background level, and the distance
to the source, all over **125 Hz to 8 kHz**, with an integration time of **at
least 10 s** (longer for non-stationary background such as traffic).

![Two panels. Panel a is a plan of a 30 by 12 metre open-plan floor split into an absorbent-raft zone and a plain-plaster zone, with a 2.0 metre keep-out band along every wall, desk clusters carrying 1.2 metre screens, source S1 at a workstation head position and source S2 at the far end firing back, eight measurement positions on a non-straight path with P1 at the nearest workstation, a 0.5 metre clearance callout at a table and the 2 to 16 metre regression window bracketed. Panel b is a section fixing the loudspeaker acoustic centre and the microphone at 1.2 metres beside a seated occupant, with the clause list for the source, the receiving chain, the room condition and the line](https://docs.jmrp.io/phonometry/media/diagram_open_plan_setup.svg)

**Why the window stops at 2 m and 16 m.** Clause 6.2 admits only positions
between 2 m and 16 m into the $D_\mathrm{2,S}$ regression, and both ends have a
reason. Nearer than 2 m the receiver sits in the talker's direct field, whose
6 dB per doubling is a property of free space rather than of the office; beyond
16 m the speech level has normally reached the background, so the regression
would be fitting noise. A line of six positions from 2 m to 16 m therefore
keeps at least four points inside the fit even if the last one has to be
discarded for sitting near a wall.

### From the measured pink noise to $L_{p,\mathrm{A,S},n}$

A loudspeaker is not a talker, so ISO 3382-3 never uses its level directly.
Clause 6.2 measures the *room* with pink noise and then re-clothes the result
in the spectrum of a real voice. What is kept from each position is not its
absolute level but the band-by-band attenuation relative to the source at 1 m
(Eq. 1-2), so the loudspeaker's output level cancels out and only has to sit
far enough above the background:

$$
L_{p,\mathrm{Ls,1m},i} \approx L_{W,\mathrm{Ls},i} - 11\ \text{dB},
\qquad
D_{n,i} = L_{p,\mathrm{Ls,1m},i} - L_{p,\mathrm{Ls},n,i} .
$$

That attenuation is then applied to the normal-effort speech spectrum
(Eq. 3), A-weighted and summed energetically over the seven octave bands
(Eq. 4):

$$
L_{p,\mathrm{S},n,i} = L_{p,\mathrm{S,1m},i} - D_{n,i},
\qquad
L_{p,\mathrm{A,S},n} = 10\log_{10}\sum_i 10^{(L_{p,\mathrm{S},n,i} + A_i)/10} .
$$

Table 1 supplies the omnidirectional normal-effort spectrum and the
A-weightings:

| Band $i$ | $f$ [Hz] | $L_{p,\mathrm{S,1m},i}$ [dB] | $A_i$ [dB] |
| ---: | ---: | ---: | ---: |
| 1 | 125 | 49.9 | −16.1 |
| 2 | 250 | 54.3 | −8.6 |
| 3 | 500 | 58.0 | −3.2 |
| 4 | 1000 | 52.0 | 0.0 |
| 5 | 2000 | 44.8 | +1.2 |
| 6 | 4000 | 38.8 | +1.0 |
| 7 | 8000 | 33.5 | −1.1 |

whose A-weighted total is 57.4 dB (a normal talking voice at 1 m).

**The A-weighted pink-noise reading on the meter is not the input
`open_plan_metrics` expects.** Feeding it in gives an absolute level that is
the loudspeaker's, not a talker's, so $L_{p,\mathrm{A,S},4\,\mathrm{m}}$ is wrong outright and
$D_\mathrm{2,S}$ is biased by the spectral difference between pink noise and speech.
Run the four-step chain first:

```python
import numpy as np
# `room` is the import of the open_plan_metrics block above.

# ISO 3382-3 Table 1: normal-effort unisex speech at 1 m, omnidirectional,
# and the A-weighting, octave bands 125 Hz to 8 kHz.
speech_1m = np.array([49.9, 54.3, 58.0, 52.0, 44.8, 38.8, 33.5])
a_weight = np.array([-16.1, -8.6, -3.2, 0.0, 1.2, 1.0, -1.1])

# Measured octave-band pink-noise levels, one row per measurement position.
pink = np.array([
    [72.0, 71.0, 70.0, 69.0, 67.0, 64.0, 60.0],
    [67.0, 66.0, 64.5, 63.0, 60.5, 57.0, 52.5],
    [63.5, 62.0, 60.0, 58.0, 55.0, 51.0, 46.0],
    [60.0, 58.5, 56.0, 53.5, 50.0, 45.5, 40.0],
])
source_1m = np.full(7, 90.0) - 11.0        # Eq. (1): Lp,Ls,1m = Lw,Ls - 11 dB

d_n = source_1m - pink                     # Eq. (2): attenuation per band
speech_n = speech_1m - d_n                 # Eq. (3): re-clothed in speech
lp_a_s = 10 * np.log10(np.sum(10 ** ((speech_n + a_weight) / 10), axis=1))
print(np.round(lp_a_s, 1))                 # [48.  42.4 37.8 33.8]  Eq. (4)

dist = np.array([2.0, 4.0, 8.0, 16.0])
chain = room.open_plan_metrics(dist, lp_a_s, 0.70 - 0.03 * dist)
print(round(chain.d2s, 1), round(chain.lp_as_4m, 1))     # 4.7 42.9
```

The band arithmetic itself (A-weighting and energetic summation) is the
same as in [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/).

### `open_plan_metrics()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `positions_m` | 1D array | m | ≥ 4 positions, all > 0 | Source-to-receiver distances |
| `spl_a_speech` | 1D array | dB | same length | A-weighted speech level $L_{p,\mathrm{A,S},n}$ per position from the Clause 6.2 Eq. (1)-(4) chain (**not** the measured pink-noise dB(A)) |
| `sti_values` | 1D array | — | same length | STI per position (full IEC 60268-16 method) |

Returns an `OpenPlanResult` with `d2s`, `lp_as_4m`, `rd` and `rp`; its
`.plot()` redraws the Clause 6.2 spatial-decay regression from those four
fields and marks `rd` / `rp`.
`d2s`/`lp_as_4m` are `nan` if fewer than two positions fall in 2–16 m;
`rd`/`rp` are `nan` when STI does not decrease with distance. The per-position
STI can itself be measured with the STIPA tools in the
[Speech Transmission Index guide](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/).

## ISO 3382-3 report (`.report()`)

`OpenPlanResult.report(path)` renders a one-page PDF fiche laid out like an
open-plan-office speech-privacy measurement report: a standard-basis line, an
optional metadata header block, a compact metrics table of the four quantities
`open_plan_metrics` returns ($D_\mathrm{2,S}$,
$L_{p,\mathrm{A,S},4\,\mathrm{m}}$, the distraction distance $r_\mathrm{D}$ and
the privacy distance $r_\mathrm{P}$) stacked above the full-width spatial-decay
plot (`.plot()`, the Clause 6.2 regression on the logarithmic distance axis
with the 4 m read-off and the $r_\mathrm{D}$ / $r_\mathrm{P}$ crossings marked,
the Figure 3 style curve), the boxed $D_\mathrm{2,S}$ with the other quantities
alongside, and a footer with the fixed disclaimer. ISO 3382-3 **characterises**
a space rather than defining an intrinsic pass/fail, so a verdict row appears
only when a target spatial decay rate is supplied through the metadata's
`requirement` field (`ReportMetadata(requirement=...)`, read as the minimum
acceptable $D_\mathrm{2,S}$ in dB, reflecting the informative quality ranges of
Annex A where a larger spatial decay is better; the room passes at or above
it). It uses the same `ReportMetadata` container and rendering engine as the
[ISO 3382-1/-2 room-acoustics
fiche](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/#iso-3382-report-report); the
open-plan-specific fields `area` (floor area), `n_source_positions` and
`n_receiver_positions` (the number of measurement positions) populate the header,
alongside `client`, `test_room` (the office or zone), `specimen` (the
description and furnishing state), `instrumentation`, `temperature_c`,
`relative_humidity_percent`, `static_pressure_kpa`, `measurement_standard`,
`test_date`, `laboratory`, `operator`, `report_id` and `notes`. Passing
`metadata=None` produces a bare characterisation fiche. The fiche embeds the
spatial-decay chart, so rendering needs both reportlab and matplotlib (`pip
install "phonometry[report,plot]"`); only `engine="reportlab"` is supported.
The fiche renders in English by default; pass `language="es"` for a Spanish
fiche (translated fixed strings and a comma decimal separator).

```python
import numpy as np
from phonometry import room, ReportMetadata

r = np.array([2.0, 3.0, 4.0, 6.0, 8.0, 11.0, 16.0])   # distances from the talker (m)
# Another stand-in line, built to a clean 7 dB per doubling as above; a
# measured one scatters about the fit by a decibel or two.
lp = 62.0 - 7.0 * np.log2(r)                           # A-weighted speech level (dB)
sti = 0.65 - 0.03 * r                                  # STI per position

result = room.open_plan_metrics(r, lp, sti)
result.report(
    "open_plan_fiche.pdf",
    metadata=ReportMetadata(
        test_room="Open-plan office B",
        specimen="Furnished, unoccupied, background noise present",
        area=420.0, n_source_positions=2, n_receiver_positions=7,
        measurement_standard="ISO 3382-3",
        temperature_c=22.0, relative_humidity_percent=45.0,
        laboratory="Phonometry Reference Laboratory",
        requirement=7.0,          # adds a verdict against a target D2,S
    ),
)                                 # D2,S + Lp,A,S,4m, rD, rP and the decay curve
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [ISO 3382-3 open-plan office acoustics example report (PDF)](https://docs.jmrp.io/phonometry/media/iso3382_3_open_plan_example.pdf): One-page open-plan-office fiche: a metadata header (client, office/zone, description, floor area, source and measurement positions, instrumentation, temperature, humidity and pressure), the metrics table of the four single-number quantities (D2,S = 7.0 dB per doubling, Lp,A,S,4m = 48.0 dB, rD = 5.0 m, rP = 15.0 m) above the spatial-decay plot on a logarithmic distance axis with the D2,S regression, the 4 m read-off and the rD and rP crossings, the boxed D2,S, and a PASS verdict against the 7.0 dB target.

Open-plan office acoustics fiche (OpenPlanResult.report): D2,S, Lp,A,S,4m, rD, rP and the spatial-decay curve.

## Crowd self-noise in an occupied room

ISO 3382-3 above **measures** an office. The complementary question at design
time is a **prediction**: in a room whose only noise source is its own
occupants, how loud does the background get, and does conversation still work?
Long (*Architectural Acoustics* 2e, Ch. 17, Eqs. (17.50) to (17.54)) sets the
two competing levels at a listener. The signal is the direct field of the
person across the table,

$$
L_p(\text{signal}) = L_W + 10\log_{10}\!\left[\frac{Q}{4\pi r^2}\right],
\quad \text{(Eq. (17.50))}
$$

and the noise is the reverberant field that $N$ simultaneous talkers build up,

$$
L_p(\text{noise}) = L_W + 10\log_{10} N + 10\log_{10}\!\left[\frac{4}{N A_\text{tab}}\right],
\quad \text{(Eq. (17.51))}
$$

with $L_W$ the sound power level of one talker (about 70 dB in normal
conversation), $Q$ the talker's forward directivity (about 2), $r$ the
talker-to-listener distance and $A_\text{tab}$ the equivalent absorption area
**per occupied table**, so $N A_\text{tab}$ is the room's total absorption.

```python
from phonometry import room

# Long's hard restaurant: about 20 metric sabins, a talker at Lw = 70 dB,
# a listener 1.2 m away across the table.
print(round(room.speech_direct_level(1.2)))          # 60 dB direct field
print(round(room.crowd_noise_level(1, 20.0)))        # 63 dB with one talker
print(round(room.crowd_noise_level(20, 20.0)))       # 76 dB with 20 tables

# An alpha 0.9 ceiling over the 13.7 x 13.7 m room adds 170 metric sabins.
print(round(room.crowd_noise_level(20, 20.0 + 170.0)))   # 66 dB
```

Subtracting the two gives the **speech-to-noise ratio**, and this is the
result worth remembering:

$$
L_\mathrm{SN} = 10\log_{10}\!\left[\frac{Q}{4\pi r^2}\right] + 10\log_{10}\!\left[\frac{A_\text{tab}}{4}\right].
\quad \text{(Eq. (17.52))}
$$

Neither $L_W$ nor $N$ survives. A busier room is not intrinsically worse,
because each new table brings both a talker and its own share of absorption.
What decides whether a restaurant works is the absorption **per table**, not
the absorption of the room. Requiring $L_\mathrm{SN} > -6$ dB for adequate
cross-table communication at a separation $r_\mathrm{s}$, and $L_\mathrm{SN} < -9$ dB so a
neighbouring table $r_\mathrm{t}$ away is not overheard, turns into a pair of design
bounds (Eqs. (17.53) and (17.54)):

$$
A_\text{tab} > 6.31\,r_\mathrm{s}^2, \qquad A_\text{tab} < 3.16\,r_\mathrm{t}^2 \qquad (Q = 2).
$$

**Caution**

**The first constant is printed as 6.33.** The closed form above, at the same
$Q = 2$ that yields Long's own second constant 3.16 exactly, gives 6.31, and
his prose ("6.3 or more square metres, 68 sq ft") converts to 6.317 m². The
library computes both bounds from the speech-to-noise ratio rather than
hardcoding either constant, so they stay mutually consistent; the misprint is
recorded in the [errata registry](https://github.com/jmrplens/phonometry/blob/main/docs/ERRATA.md).

```python
from phonometry import room

print(round(room.absorption_per_table(1.0, -6.0), 2))   # 6.31 m2 per table at 1 m
print(round(room.absorption_per_table(2.5, -9.0), 1))   # 19.8 m2 at 2.5 m spacing

# A real layout: 1.2 m across the table, 2.0 m to the next one.
print(round(room.absorption_per_table(1.2, -6.0), 2))   # 9.09 m2, the floor
print(round(room.absorption_per_table(2.0, -9.0), 2))   # 12.66 m2, the ceiling

crowd = room.crowd_noise([20.0, 95.0, 190.0], distance=1.2)
crowd.plot()      # self-noise vs occupancy, against the -6 dB limit
```

The two bounds are a **window**, and it can be empty. Requiring
$6.31\,r_\mathrm{s}^2 < A_\text{tab} < 3.16\,r_\mathrm{t}^2$ means the window exists only when
$r_\mathrm{t}/r_\mathrm{s} > \sqrt{6.31/3.16} \approx 1.41$: pack the tables closer than that and
there is no absorption at all that lets you converse across your own table
without being overheard at the next one. The layout above passes, with
$r_\mathrm{t}/r_\mathrm{s} = 1.67$ and 3.6 m² of room between the bounds.

![Two panels. On the left, absorption per occupied table against separation, with the communication bound 6.31 r squared rising above the privacy bound 3.16 r squared, the two worked points at 1 metre and 2.5 metres marked, and the feasible band from 9.1 to 12.7 square metres shaded for a layout with 1.2 metres across the table and 2.0 metres between tables. On the right, the width of that feasible window against the ratio of table spacing to cross-table separation, crossing zero at 1.41 and reaching 3.6 square metres at the ratio 1.67 of this layout](https://docs.jmrp.io/phonometry/media/absorption_per_table.svg)

*Left: for one layout the two inequalities leave a band of feasible absorption
per table. Right: how wide that band is as the tables move apart, below
$r_\mathrm{t}/r_\mathrm{s} = 1.41$ it has negative width, which is the geometric statement that
conversation and privacy have become incompatible whatever the ceiling is made
of.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
# `room` is the import of the block above.

span = np.linspace(0.6, 3.2, 200)
plt.plot(span, room.absorption_per_table(span, -6.0), label="communication")
plt.plot(span, room.absorption_per_table(span, -9.0), label="privacy")

r_s, r_t = 1.2, 2.0
lower = float(room.absorption_per_table(r_s, -6.0))
upper = float(room.absorption_per_table(r_t, -9.0))
plt.axhspan(lower, upper, alpha=0.2)
print(round(upper - lower, 1), round(r_t / r_s, 2))     # 3.6 1.67
print(round(float(np.sqrt(6.31 / 3.16)), 2))            # 1.41: the closure ratio
plt.legend(); plt.show()
```

**Where $A_\text{tab}$ itself comes from.** For a room that exists, measure the
reverberation time to ISO 3382-2 and invert Sabine: $A = 0.161\,V/T$ (the same
convention ISO 354 defines). The
[room impulse response](https://docs.jmrp.io/phonometry/buildings/rooms/room-impulse-response/)
and [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/) guides
supply $T$. For a room being designed, take it off surface by surface as in
[Sound absorption in enclosed spaces](https://docs.jmrp.io/phonometry/buildings/rooms/enclosed-space-absorption/).
Either way $A_\text{tab} = A/N$ with $N$ the number of **simultaneously
occupied** tables (not the covers, and not the tables installed). That is what
makes a half-full restaurant a different room from a full one at the same
absorption, and it is why adding tables at fixed absorption is what pushes a
room past its limit. It also means a T30 measured in the empty room is enough
to predict how it will sound full.

![Self-generated crowd noise level against the number of simultaneous talkers for three room absorption areas of 20, 95 and 190 metric sabins, with the 60 dB direct speech level at 1.2 m and the 66 dB communication limit drawn as horizontal references](https://docs.jmrp.io/phonometry/media/restaurant_crowd_noise.svg)

*The same 20 talkers in three rooms. The hard room (20 m² of absorption)
crosses the communication limit before the fourth table is occupied; adding
the absorptive ceiling of Long's example (190 m² in total) keeps all 20 tables
below it. The curves are parallel because occupancy always costs $10\log_{10} N$:
only the vertical offset, which is the absorption, is a design variable.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import room

# One line — the occupancy sweep straight from the result:
result = room.crowd_noise([20.0, 95.0, 190.0], distance=1.2)
result.plot()
plt.show()

# Or draw it by hand from Equation (17.51):
n = np.arange(1, 21)
fig, ax = plt.subplots()
for area in (20.0, 95.0, 190.0):
    ax.plot(n, room.crowd_noise_level(n, area), label=f"A = {area:.0f} m²")
signal = room.speech_direct_level(1.2)
ax.axhline(signal, ls="--", label="Speech at 1.2 m")
ax.axhline(signal + 6.0, ls=":", label="Communication limit")
ax.set(xlabel="Simultaneous talkers N", ylabel="Self-generated noise level [dB]")
ax.legend()
plt.show()
```

### `crowd_noise()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `absorption_areas` | float or 1D array | m² | > 0 | Total room absorption areas to compare |
| `talkers` | 1D array, optional | — | ≥ 1, default 1..20 | Occupancy axis $N$ |
| `distance` | float | m | > 0, default 1.2 | Talker-to-listener distance $r$ |
| `sound_power_level` | float | dB re 1 pW | default 70 | Talker $L_W$ |
| `directivity` | float | — | > 0, default 2 | Talker $Q$ |

Returns a `CrowdNoiseResult` (`talkers`, `absorption_areas`, `levels`,
`signal_level`, `communication_level`, `speech_to_noise()`) with `.plot()`.
The pieces `speech_direct_level`, `crowd_noise_level`, `speech_to_noise_ratio`
and `absorption_per_table` are callable directly.

## What this guide covers

- **Covered.** ISO 3382-3:2012 Clause 4 and Clause 6.2/6.3 open-plan quantities ($D_\mathrm{2,S}$,
  $L_{p,\mathrm{A,S},4\,\mathrm{m}}$, $r_\mathrm{D}$, $r_\mathrm{P}$) from `room.open_plan_metrics`, with the to-scale
  measurement-line drawing (`room.plot_open_plan_geometry` and
  `.plot_geometry()`) and the one-page ISO 3382-3 fiche through `.report()`. The
  clause 5.1 and 5.2 measurement conditions and the Annex A quality ranges are
  quoted here for planning and reading. Long's *Architectural Acoustics* 2e
  Chapter 17 crowd self-noise model (Eqs. (17.50) to (17.54)) through
  `room.crowd_noise` and its parts, with the Eq. (17.53)-(17.54) design window
  and its closure condition. The
  [conformance report](https://docs.jmrp.io/phonometry/reference/conformance/) holds $D_\mathrm{2,S}$
  to the standard's own definition of it.

- **Not covered.** ISO 3382-3's per-position STI is taken as an input to `open_plan_metrics`
  rather than computed inside it: measure it with the STIPA tools of the [Speech
  Transmission Index guide](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/).
  The fourth required single number, the average A-weighted background noise
  $L_{p,\mathrm{A,B}}$, is likewise not computed here. It is the energetic A-weighted
  average of the per-position octave-band background levels, and it belongs in
  the report alongside the three this page produces. Nothing **checks** the
  measurement conditions of clauses 5.1 and 5.2 either: the function consumes
  distances, levels and STI values wherever they came from, so the source
  directivity, the furnished-and-unoccupied state and the background capture are
  the operator's responsibility, not the library's. The implemented edition is
  frozen at ISO 3382-3:2012; the superseding ISO 3382-3:2022 revision removes
  the privacy distance $r_\mathrm{P}$, adds the comfort distance $r_\mathrm{C}$ and moves the
  per-position STI to the indirect IEC 60268-16 method, and is not the one
  checked here. The crowd self-noise model is a *design* calculation and
  deliberately does not model the Lombard reflex: it cancels out of $L_\mathrm{SN}$ as
  long as everyone raises their voice equally, so the model explains why the
  level spirals upward in a hard room rather than predicting where it stops. It
  also assumes a diffuse reverberant field and a single absorption figure per
  table, so it says nothing about screens, local absorption or where in the room
  a given table sits.

## See also

- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the ISO 3382-1/2
  decay parameters of the same room.
- [Measuring the Room Impulse Response](https://docs.jmrp.io/phonometry/buildings/rooms/room-impulse-response/):
  the acquisition behind the per-position levels.
- [Speech Transmission Index](https://docs.jmrp.io/phonometry/perception/speech/speech-transmission/): the
  STI/STIPA measurement that feeds the per-position `sti_values`.
- [Speech Intelligibility Index](https://docs.jmrp.io/phonometry/perception/speech/speech-intelligibility/):
  the ANSI S3.5 view of the same intelligibility question.
- [Levels](https://docs.jmrp.io/phonometry/signals/levels/levels/): the A-weighted levels behind the
  spatial decay.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/): the room-acoustic
  derivations this page builds on.
- API reference: [`room.open_plan`](https://docs.jmrp.io/phonometry/reference/api/rooms/open-plan/).
- Theory: [Impulse response and room-acoustic parameters](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/#impulse-response-and-room-acoustic-parameters-iso-18233-iso-3382-1-2-3): the decay and absorption theory the ISO 3382-3 distraction distance is measured against.

## References

- **International Organization for Standardization. (2012).** [*Acoustics — Measurement of room acoustic parameters — Part 3: Open plan offices*](https://www.iso.org/standard/46520.html) (ISO 3382-3:2012).
  The open-plan speech-privacy quantities this page implements. Since revised as ISO 3382-3:2022 (https://www.iso.org/standard/77437.html); the 2012 edition is the implemented one.
- **Long, M. (2014).** *Architectural acoustics* (2nd ed.). Academic Press. https://doi.org/10.1016/C2012-0-03257-5
  The crowd self-noise model of Chapter 17, Equations (17.50) to (17.54).