# Spanish Building Code (CTE DB-HR)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/insulation/spanish-building-code/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/insulation/spanish-building-code/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-29
Updated: 2026-11-16T21:36:14Z
Verified: 3 conformance checks (CTE DB-HR; Catálogo informático de elementos constructivos (CEC)) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: CTE DB-HR global index: the Annex A formula over eighteen one-third-octave bands, normalized spectra, rounding, requirements and window correction.

---

The *Documento Básico HR* "Protección frente al ruido" of the Spanish building
code states its requirements in A-weighted global quantities that are close
relatives of, but not identical to, the ISO 717-1 weighted ratings: $R_\mathrm{A}$,
$R_\mathrm{A,tr}$, $D_{\mathrm{n}T,\mathrm{A}}$ and $D_{2\mathrm{m,n}T,\mathrm{Atr}}$. This page implements the direct
Annex A route, which is the normative one for DB-HR, the requirement tables of
clause 2, and the two design calculations most often used with them: the
window-size correction and the insulation of a composite façade.

The band spectra it consumes come from field measurement or from prediction;
the ISO 717 reference-curve engine, which it is worth not confusing this with,
is in [Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/).

## The global index of Annex A

Instead of shifting a reference curve, DB-HR weights the measured band
insulation with a normalised source spectrum and sums it energetically
(Formulae A.5 to A.7, A.14, A.17 and A.18):

$$
I_x = -10 \log_{10} \sum_i 10^{(L_{x,i} - X_i)/10} \quad \text{[dBA]}
$$

where $X_i$ is the band insulation (the sound reduction index $R$ or $R'$, the
standardized level difference $D_{\mathrm{n}T}$, $D_{2\mathrm{m,n}T}$ and so on) and $L_{x,i}$
the normalised source spectrum. The sum runs over **eighteen** one-third-octave
bands, 100 Hz to 5 kHz, two more than the sixteen of ISO 717-1 (100 Hz to
3150 Hz): the 4 kHz and 5 kHz bands, which are the first reason the two routes
do not always agree. The band centres are in `DB_HR_FREQUENCIES_HZ`.

| Normalised spectrum | Annex A table | Quantity it defines | Formula |
| :--- | :--- | :--- | :--- |
| A-weighted pink noise, $L_{\mathrm{Ar},i}$ | Table A.5 | $R_\mathrm{A}$, $R'_\mathrm{A}$, $D_{\mathrm{n}T,\mathrm{A}}$, $D_{2\mathrm{m,n}T,\mathrm{A}}$ | (A.17), (A.14), (A.7), (A.5) |
| Road traffic, $L_{\mathrm{Atr},i}$ | Table A.3 | $R_\mathrm{A,tr}$, $D_{2\mathrm{m,n}T,\mathrm{Atr}}$ | (A.18), (A.6) |
| Railway noise, $L_{\mathrm{Aef},i}$ | Table A.4 (numerically identical to A.3) | $D_{2\mathrm{m,n}T,\mathrm{A}}$ | (A.5) |
| Aircraft noise, $L_{\mathrm{Aav},i}$ | Table A.2 | $D_{2\mathrm{m,n}T,\mathrm{Atr}}$ | (A.6) |

The railway row is the one worth reading twice. Clause 3.1.3.4 point 1 says
that where railway noise dominates the façade is assessed in
$D_{2\mathrm{m,n}T,\mathrm{A}}$ through formula (A.5), and only road traffic and aircraft give
$D_{2\mathrm{m,n}T,\mathrm{Atr}}$ through (A.6); Table H.1 prints the same split. Because
Table A.4 is digit for digit Table A.3, a rail-dominant façade comes out at
the same *number* as a road one, but the quantity the requirement and the
report are stated in is not the same. That is why `d2m_nt_a()` and
`d2m_nt_atr()` are separate entry points and each refuses the other's
spectra, rather than one function with a spectrum switch that would silently
put the wrong name on the result.

All four are in `DB_HR_NORMALIZED_SPECTRA` under the keys `"pink"`,
`"traffic"`, `"railway"` and `"aircraft"`. The calculation below reproduces
Ejemplo 7.2 of the *Manual*, the apparent sound reduction index $R'$ of a party
wall taken from a real field test report. Given $R'$, `ra()` sums the same
pink spectrum and returns the apparent index $R'_\mathrm{A}$ of Formula (A.14),
still named `"RA"`:

```python
from phonometry import building

r_prime = [36.2, 41.5, 36.9, 40.4, 44.7, 42.4, 45.7, 46.1, 47.1,
           52.3, 54.3, 57.5, 57.8, 57.3, 59.0, 62.8, 64.7, 65.3]
index = building.ra(r_prime)
index.value        # 51.44 dBA
index.intermediate # 51.4 dBA, the one-decimal intermediate
index.reported     # 51 dBA, the integer that defines the requirement
```

![CTE DB-HR global index R'A: per-band apparent sound reduction index as bars with the pink-noise weighted transmitted level per band, whose energy sum sets the 51.4 dBA index](https://docs.jmrp.io/phonometry/media/dbhr_global_index.svg)

*`DBHRGlobalIndexResult.plot()` draws the band insulation together with the
transmitted level weighted by the normalised spectrum. The point is the second
curve: it shows at a glance which bands carry the energy sum, and therefore
where the element has to be improved. Here the weighted transmitted level peaks
in the low bands where `R'` is weakest, so the 51.4 dBA index is decided well
below 500 Hz.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
from phonometry import building

r_prime = [36.2, 41.5, 36.9, 40.4, 44.7, 42.4, 45.7, 46.1, 47.1,
           52.3, 54.3, 57.5, 57.8, 57.3, 59.0, 62.8, 64.7, 65.3]

building.ra(r_prime).plot()
plt.show()
```

`ra()`, `ra_tr()`, `dnt_a()`, `d2m_nt_a()` and `d2m_nt_atr()` are named shortcuts over
`db_hr_global_index()`, which accepts any spectrum and, given the
`frequencies` argument, selects the eighteen DB-HR bands out of a longer
series.

## Rounding and the relationship with the ISO 717 route

Clause 3.1.3.1 point 4 of DB-HR requires the final values of the quantities
that define the requirements to be expressed rounded to an integer, while
intermediate values are carried with one decimal. The result object therefore
exposes all three forms: `.value` (unrounded), `.intermediate` (one decimal)
and `.reported` (the integer used in the check).

DB-HR and ISO 717-1 reach the same place by different routes, and Annex H of
the document itself accepts three approximations as long as the two routes
differ by less than 1 dB:

$$
D_{\mathrm{n}T,\mathrm{A}} \approx D_{\mathrm{n}T,\mathrm{w}} + C \quad (H.1), \qquad
D_{2\mathrm{m,n}T,\mathrm{A}} \approx D_{2\mathrm{m,n}T,\mathrm{w}} + C \quad (H.2), \qquad
D_{2\mathrm{m,n}T,\mathrm{Atr}} \approx D_{2\mathrm{m,n}T,\mathrm{w}} + C_\mathrm{tr} \quad (H.3)
$$

with (H.2) covering the rail-dominant case of the previous section. On the two
published spectra this page reproduces, the agreement is exact to the integer:

| Case | Direct route (Annex A) | ISO 717-1 route | Published? |
| :--- | :--- | :--- | :--- |
| Separating wall of Ejemplo 7.2 | $R'_\mathrm{A} = 51.4$ dBA, rounded to 51 | $R'_\mathrm{w} = 52$ with $C_{100-5000} = -1$, i.e. 51 | yes, Ejemplo 7.1 prints $R'_\mathrm{w} = 52$, $C = -1$ and the 51 dBA |
| Façade of Ejercicio 7.1 | $D_{2\mathrm{m,n}T,\mathrm{Atr}} = 32.8$ dBA, rounded to 33 | $D_{2\mathrm{m,n}T,\mathrm{w}} = 38$ with $C_{\mathrm{tr},100-5000} = -5$, i.e. 33 | no, the book prints neither 38 nor $-5$ |

The two rows are not equally strong evidence. The wall row is a genuine
external check, because the *Manual* prints the ISO 717-1 numbers as well as
the direct one. For the façade the book publishes only the 32.8 dBA; the 38
and the $-5$ come from this library's own ISO 717-1 engine, so that row shows
the two routes agreeing with each other rather than agreeing with a source.

The real trap is the name of the spectrum adaptation terms. Annex H writes
them as plain $C$ and $C_\mathrm{tr}$ and refers their definition to
UNE-EN ISO 717-1 without narrowing the frequency range. Since the DB-HR
indices run to 5 kHz while the ISO 717-1 core range stops at 3150 Hz, the
terms that make (H.1) to (H.3) come out right are the **enlarged-range**
$C_{100-5000}$ and $C_{\mathrm{tr},100-5000}$; that reading is not in Annex H itself
but in the *Manual*, in the note to expressions [7.15] and [7.16]. It matters:
on the façade of Ejercicio 7.1 the core-range $C$ is $-2$ while $C_{100-5000}$
is $-1$, so taking the wrong one gives 36 dBA instead of 37 for the
$D_{2\mathrm{m,n}T,\mathrm{A}}$ of that façade. On the same specimen $C_\mathrm{tr}$ and
$C_{\mathrm{tr},100-5000}$ are both $-5$, so the $D_{2\mathrm{m,n}T,\mathrm{Atr}}$ that DB-HR actually
requires happens not to discriminate between the two readings at all.

```python
from phonometry import building

d2m_nt = [28.5, 28.5, 18.9, 23.7, 30.7, 31.3, 37.8, 35.2, 34.7,
          38.5, 37.7, 43.1, 42.3, 44.2, 41.9, 37.5, 39.4, 41.5]

direct = building.d2m_nt_atr(d2m_nt)
direct.intermediate, direct.reported   # 32.8 dBA -> 33 dBA

iso = building.weighted_rating_extended(d2m_nt, frequencies=building.DB_HR_FREQUENCIES_HZ)
iso.rating, iso.ctr_100_5000           # 38 dB, -5 dB -> 33 dBA, the same figure
iso.c, iso.c_100_5000                  # -2 and -1: core range versus enlarged range
```

## The requirements of clause 2

DB-HR states its requirements on two kinds of room: the **protected room**
(*recinto protegido*, a habitable room with reinforced acoustic protection:
bedrooms, living areas, classrooms, operating theatres, professional offices)
and the **habitable room** (*recinto habitable*) in general.

![Section through a three-storey residential building between a street and a party wall, with each DB-HR requirement written on the element it applies to. On the street a car stands for road traffic and a microphone stands 2 m in front of the facade for L1,2m; the bedroom facade carries D2m,nT,Atr of at least 32 dBA, the Table 2.1 value for a bedroom where the Ld of the zone, taken from the noise map, is over 60 and up to 65 dBA. Inside, the partition between a bedroom and a living room carries RA of at least 33 dBA, the wall between two dwellings DnT,A of at least 50 dBA, the floor between two bedrooms of different dwellings L′nT,w of at most 65 dB, and the floor over the ground-floor shop DnT,A of at least 55 dBA under the bedroom and L′nT,w of at most 60 dB under the hall. The hall door onto the common landing carries RA of at least 20 dBA and the wall around it RA of at least 50 dBA, and the party wall takes either D2m,nT,Atr of at least 40 dBA on each leaf or DnT,A of at least 50 dBA for both leaves together. Four lines under the ground add 45 dBA for a habitable room, 30 dBA for a door shared with a protected room, 60 dBA as the Ld of a residential area with no official value, Ld less 10 dBA for a facade not directly exposed to the noise and 4 dBA more on the limit where aircraft dominate. Below, four boxes joined by arrows follow Annex A: the band insulation over eighteen one-third octaves from 100 Hz to 5 kHz, with the sound reduction index from the laboratory and the two standardised level differences normalised to a reference time of 0.5 s; the normalised spectrum of Tables A.2 to A.5, picked by the dominant noise; the energy sum of Formulae A.5 to A.7 for the level differences and A.17 for RA; and the rounding to one decimal while working and to an integer in DnT,A and L′nT,w, with 52.7 dBA becoming 53 dBA against the 50 dBA limit. Two lines note that impact sound goes through the ISO 717-2 reference curve instead and that a catalogue window loses 1 to 3 dB as its area grows past 2.7, 3.6 and 4.6 square metres, and a box at the foot holds the index: minus ten lg of the sum over the bands of ten to the power of the spectrum less the insulation, divided by ten](https://docs.jmrp.io/phonometry/media/diagram_db_hr_requirements.svg)

*Clause 2 on the elements of one building, from the partition inside a dwelling
to the party wall, and the Annex A chain that turns eighteen bands into the
rounded number each airborne limit is read against.*

**Façades (Table 2.1).** The requirement on $D_{2\mathrm{m,n}T,\mathrm{Atr}}$ is read by bands of
the site's day noise index $L_\mathrm{d}$ ($L_\mathrm{d} \le 60$, $60 < L_\mathrm{d} \le 65$,
$65 < L_\mathrm{d} \le 70$, $70 < L_\mathrm{d} \le 75$ and $L_\mathrm{d} > 75$ dBA):

| Use | Room | `db_hr_facade_requirement(ld, use, room)` | $\le 60$ | 60-65 | 65-70 | 70-75 | $> 75$ |
| :--- | :--- | :--- | ---: | ---: | ---: | ---: | ---: |
| Residential, hospital | Bedrooms | `"residential"`, `"bedrooms"` | 30 | 32 | 37 | 42 | 47 |
| Residential, hospital | Living areas | `"residential"`, `"living"` | 30 | 30 | 32 | 37 | 42 |
| Cultural, health, educational, administrative | Living areas | `"cultural"`, `"living"` | 30 | 32 | 37 | 42 | 47 |
| Cultural, health, educational, administrative | Classrooms | `"educational"`, `"classrooms"` | 30 | 30 | 32 | 37 | 42 |

The same phrase means different things in the two use groups, which is why the
printed table's single "use and room" column is easy to misread: *living areas*
carry the stricter row under a cultural or educational use and the more lenient
one under a residential use.

Three rules modify the reading: a façade not directly exposed to the dominant
noise (an enclosed courtyard, a quiet surrounding) is assessed with $L_\mathrm{d}$
reduced by 10 dBA, where aircraft noise dominates the table value is increased
by 4 dBA, and where no official $L_\mathrm{d}$ exists for the site, 60 dBA is assumed
for residential acoustic areas.

**Airborne insulation between rooms (clause 2.1.1).** Partition walls
(*tabiquería*) within one use unit must have $R_\mathrm{A} \ge 33$ dBA. Against a room
of another use unit, a protected room requires $D_{\mathrm{n}T,\mathrm{A}} \ge 50$ dBA and a
habitable room $\ge 45$ dBA; against a services or activity room, a protected
room requires $\ge 55$ dBA and a habitable room $\ge 45$ dBA. When the two
rooms share a door or a window, the requirement moves to the opening (sound
reduction index of 30 dBA for the protected room, 20 dBA for the habitable
one) and to the enclosure around it (50 dBA).

**Party walls (clause 2.1.1 c).** Against a *medianería* DB-HR offers two
**alternative** routes, not cumulative ones: either each of the two leaves
reaches $D_{2\mathrm{m,n}T,\mathrm{Atr}} \ge 40$ dBA, or the two leaves taken together reach
$D_{\mathrm{n}T,\mathrm{A}} \ge 50$ dBA. `db_hr_party_wall_requirement()` returns whichever route
is asked for.

**Impact sound (clause 2.1.2).** The standardized impact sound pressure level
$L'_{\mathrm{n}T,\mathrm{w}}$ must not exceed 65 dB in a protected room against a room of another
use unit, nor 60 dB against a services or activity room; that same 60 dB limit
applies to the habitable room.

**Reverberation and absorption (clause 2.2).** The reverberation time must not
exceed 0.7 s in an empty classroom or conference hall under 350 m³, 0.5 s with
the fixed seating installed, or 0.9 s in empty restaurants and dining rooms. In
common areas sharing doors with protected rooms, the equivalent sound
absorption area must be at least 0.2 m² per cubic metre of volume.

```python
import numpy as np
from phonometry import building

facade = building.db_hr_facade_requirement(65.0, "residential", "bedrooms")
facade.limit                                        # 32 dBA (Table 2.1)

airborne = building.db_hr_airborne_requirement("protected", "other_unit")
[(r.quantity, r.limit) for r in airborne]           # [("DnT,A", 50.0)]

building.db_hr_impact_requirement("protected", "other_unit").limit    # 65 dB
building.db_hr_party_wall_requirement().limit                         # 40 dBA per leaf
building.db_hr_party_wall_requirement("DnT,A").limit                  # 50 dBA both together
building.db_hr_reverberation_requirement("classroom").limit           # 0.7 s

# The between-rooms requirement is stated in DnT,A, so the party-wall R' of the
# field report cannot be checked against it as it stands. Re-reference it first:
# a receiving room of V = 50 m3 with T = 0.5 s behind a partition of S = 12 m2
# has A = 0.16 V / T = 16 m2, and DnT = R' + 10 lg(A/S) + 10 lg(T/T0).
d_nt = np.asarray(r_prime) + 10 * np.log10(16.0 / 12.0) + 10 * np.log10(0.5 / 0.5)
building.dnt_a(d_nt).intermediate                   # 52.7 dBA (R'A was 51.4 dBA)

check = building.assess_db_hr([(33.0, facade), (52.7, airborne[0])])
check.passes                                      # True
```

The quantity has to match the requirement. DB-HR states the between-rooms limit
in $D_{\mathrm{n}T,\mathrm{A}}$, and $R'$ and $D_{\mathrm{n}T}$ normalise the same level difference by
different things: $R' = D + 10\log_{10}(S/A)$ by the partition area and the
receiving-room absorption, $D_{\mathrm{n}T} = D + 10\log_{10}(T/T_0)$ by the
reverberation time. So an $R'_\mathrm{A}$ from a field report has to be converted
through the room's $T$ and the partition area before it means anything against
the 50 dBA. Only the *tabiquería* requirement ($R_\mathrm{A} \ge 33$ dBA) is stated in
the $R_\mathrm{A}$ family. Earlier revisions of this page checked the party wall's
$R'_\mathrm{A} = 51.4$ dBA straight against the $D_{\mathrm{n}T,\mathrm{A}}$ requirement: the verdict
happened to come out the same here, but the comparison was between two
different quantities and nothing guarantees the agreement in general.

`check_db_hr_requirement()` rounds the achieved value the way DB-HR asks before
comparing it (to an integer for the dB quantities, to one decimal for the
reverberation time) and returns the margin; `assess_db_hr()` does the same over
a list of value-requirement pairs. The `DBHRAssessment` it returns draws the
achieved values against their limits with `.plot()`, one per checked
requirement.

## Windows and composite façades

The tests that determine the sound reduction index of a window are run on
specimens of about 1.8 m², and a larger window insulates less. The *Catálogo de
Elementos Constructivos* of the building code corrects the catalogue value of
$R_\mathrm{A}$ and $R_\mathrm{A,tr}$ by total window area: 0 dB up to 2.7 m², $-1$ dB between
2.7 and 3.6 m², $-2$ dB between 3.6 and 4.6 m² and $-3$ dB above 4.6 m². A 4 m²
sliding window with 4-6-4 glazing, catalogued at $R_\mathrm{A} = 26$ dBA, ends up at
24 dBA (Ejemplo 7.4).

A real façade is not a homogeneous element: it has a blind part and one or more
openings. The sound reduction index of the whole follows from the
area-weighted sum of the transmittances, which is what
`composite_transmission_loss()` does in
[Predicting Panel Sound Insulation](https://docs.jmrp.io/phonometry/buildings/design/panel-sound-insulation/).
With the 8 m² façade of Ejemplo 7.5, a blind part of 40 dBA and a 2 m² window
of 26 dBA, the whole comes out at 31.5 dBA:

```python
from phonometry import building
from phonometry.building.prediction.aperture_transmission import composite_transmission_loss

building.window_size_correction(4.0)          # -2 dB: 26 dBA catalogued -> 24 dBA

composite_transmission_loss([6.0, 2.0], [40.0, 26.0])   # 31.53 dBA
composite_transmission_loss([6.0, 2.0], [50.0, 26.0])   # 31.97 dBA: +10 dBA on the blind part
composite_transmission_loss([6.0, 2.0], [40.0, 31.0])   # 35.63 dBA: +5 dBA on the window
```

Those last three lines hold the most useful rule of thumb in façade design:
improving the blind part by 10 dBA raises the overall insulation by 0.4 dBA,
practically nothing, whereas improving the window by 5 dBA raises it by
4.1 dBA, almost the full increment. The weak element is where the effort pays.

![Overall facade RA against the window RA from 20 to 55 dBA for three blind-part values of 40, 50 and 60 dBA, on the Ejemplo 7.5 geometry of a 6 square metre blind part and a 2 square metre window, with the three printed cases marked and each curve saturating at its own blind-part asymptote](https://docs.jmrp.io/phonometry/media/composite_facade_weak_element.svg)

*The rule of thumb made general. While the window is the weak element the three
curves lie on top of each other: the blind part is irrelevant, which is why
adding 10 dBA to it bought 0.4 dBA, and each curve only lifts off once the
window comes within a few decibels of it, then flattens onto the blind part's
own value as its asymptote. Design reads off the x-axis: work on whichever
element the curve is still following.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
# `composite_transmission_loss` is the import of the block above.

window = np.linspace(20.0, 55.0, 351)
fig, ax = plt.subplots()
for blind in (40.0, 50.0, 60.0):
    overall = [composite_transmission_loss([6.0, 2.0], [blind, float(w)])
               for w in window]
    ax.plot(window, overall, label=f"blind part RA = {blind:g} dBA")
    ax.axhline(blind, linestyle=":", alpha=0.6)
for w_val, blind in ((26.0, 40.0), (26.0, 50.0), (31.0, 40.0)):
    ax.plot([w_val], [composite_transmission_loss([6.0, 2.0], [blind, w_val])],
            "o", color="black")
ax.set(xlabel="Window RA [dBA]  (2 m2 of an 8 m2 facade)",
       ylabel="Overall facade RA [dBA]")
ax.legend()
plt.show()
```

## What this guide covers

- **Covered.** The DB-HR Annex A global index (Formulae A.5 to A.7, A.14, A.17 and A.18) over
  the eighteen bands from 100 Hz to 5 kHz with the four normalised spectra of
  Tables A.2 to A.5, the rounding of clause 3.1.3.1 point 4, the requirements of
  clause 2 (Table 2.1 for façades, 2.1.1 airborne and party walls, 2.1.2 impact
  and 2.2 reverberation and absorption) and the window-size correction of the
  *Catálogo de Elementos Constructivos*.

- **Not covered.** The design options of clause 3 (the simplified option with its solution
  tables, and the general option, which is the EN 12354 prediction) are not
  implemented here: the calculation route of the general option lives in
  [Predicting Sound Insulation (EN
  12354)](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/). The execution
  conditions of clause 5 and the maintenance conditions of clause 6 are out of
  scope as well.

## See also

- [Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/): the reference-curve route with $R_\mathrm{w}$, $C$, $C_\mathrm{tr}$ and the enlarged-range terms that DB-HR calls simply $C$ and $C_\mathrm{tr}$.
- [Spanish Noise Regulation (RD 1367/2007)](https://docs.jmrp.io/phonometry/environment/assessment/spanish-noise-regulation/): where the site's day noise index $L_\mathrm{d}$ that Table 2.1 is entered with comes from.
- [Façade Sound Insulation](https://docs.jmrp.io/phonometry/buildings/insulation/facade-insulation/): the ISO 16283-3 measurement of $D_{2\mathrm{m,n}T}$ and its EN 12354-3 prediction, which feed the $D_{2\mathrm{m,n}T,\mathrm{Atr}}$ index of this page.
- [Predicting Panel Sound Insulation](https://docs.jmrp.io/phonometry/buildings/design/panel-sound-insulation/): the composite-façade calculation and transmission through openings and slits.
- [Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/): the band spectra of $R'$, $D_{\mathrm{n}T}$ and $L'_{\mathrm{n}T}$ that these global quantities summarise.
- API reference: [`building.regulation.spain`](https://docs.jmrp.io/phonometry/reference/api/building/spain/).
- Theory: [Sound insulation and absorption, measured](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/#sound-insulation-and-absorption-measured-iso-16283-iso-10140-iso-717-iso-354): the quantities the code requires, derived from ISO 12354 and ISO 717 rather than from the code.

## Quick answers

### How does the DB-HR index RA differ from the Rw of ISO 717-1?

The $R_\mathrm{w}$ of ISO 717-1 comes from shifting a reference curve over sixteen
one-third-octave bands (100 Hz to 3150 Hz). The $R_\mathrm{A}$ of DB-HR comes from
weighting the band sound reduction index with a normalised pink-noise spectrum
and summing energetically over **eighteen** bands (100 Hz to 5 kHz). DB-HR
accepts the equivalence $R_\mathrm{A} \approx R_\mathrm{w} + C$, but that $C$ is the
enlarged-range term $C_{100-5000}$, not the core-range one.

## References

- **Avilés López, R., & Perera Martín, R. (2017).** *Manual de acústica ambiental y arquitectónica*. Paraninfo.
  Ejemplo 7.2 and Ejercicio 7.1 (pp. 394-395) are the numeric oracles of the global index on this page, and Ejemplos 7.4 and 7.5 (pp. 408-410) the window-size correction and the composite-façade calculation. ISBN 978-84-283-3814-1.
- **Instituto de Ciencias de la Construcción Eduardo Torroja (CSIC). (n.d.).** [*Catálogo informático de elementos constructivos (CEC)*](https://www.codigotecnico.org/Programas/CatalogoElementosConstructivos.html). Código Técnico de la Edificación.
  The building code's catalogue of construction elements, whose correction of a catalogued window's RA and RA,tr by its total area the window section implements.
- **Ministerio de Fomento (Spain). (2019).** [*Código Técnico de la Edificación, Documento Básico HR Protección frente al ruido*](https://www.codigotecnico.org/pdf/Documentos/HR/DBHR.pdf) (CTE DB-HR).
  The Annex A global index (Formulae A.5 to A.7, A.14, A.17 and A.18) and its normalised spectra (Tables A.2 to A.5), the rounding of clause 3.1.3.1 point 4 and the requirements of clause 2 (Table 2.1 for façades, 2.1.1 airborne, 2.1.2 impact and 2.2 reverberation).
- **Ministerio de la Presidencia (Spain). (2007).** [*Real Decreto 1367/2007, developing Ley 37/2003 del Ruido on acoustic zoning, quality objectives and acoustic emissions*](https://www.boe.es/buscar/act.php?id=BOE-A-2007-18397) (RD 1367/2007 (BOE-A-2007-18397), consolidated text).
  The site's day noise index Ld that Table 2.1 of DB-HR is read against comes from the acoustic zoning and the noise maps regulated here.