# Sound Insulation by Intensity (ISO 15186)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/insulation/insulation-intensity/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/insulation/insulation-intensity/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-28
Updated: 2026-11-16T21:36:14Z
Standards: ISO 15186-1:2000; ISO 15186-2:2003; ISO 15186-3:2002
Verified: 5 conformance checks (ISO 15186-1:2000; ISO 15186-3:2002) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Sound insulation by intensity (ISO 15186): RI from scanning the radiating face, Kc adaptation to ISO 10140, small-element level difference and fiches.

---

A reverberation room reads transmitted sound power *indirectly*: the
receiving room integrates every watt that arrives, whichever path carried
it, and the absorption area converts the room level back into a power. The
**sound-intensity** method of ISO 15186 replaces that inference with a
direct reading: a p-p intensity probe scans a measurement surface that
encloses the specimen and measures the power radiated by the test element
alone, so flanking transmission stays out of the number. This guide covers
the intensity sound reduction index $R_I$ and its $K_\mathrm{c}$-modified form, the
element-normalized level difference of small building elements, the surface
qualification indicator and the accredited test fiches. The pressure-based
laboratory chain lives in
[Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/); the
probe physics and its field indicators are the subject of the
[Sound Intensity guide](https://docs.jmrp.io/phonometry/devices/emission/intensity/).

## Measuring the transmitted power directly (ISO 15186-1)

The quantity being measured is a **surface integral**: the net sound power
crossing an imaginary surface drawn around the radiating face of the specimen,
$W = \int_S \mathbf{I} \cdot \mathbf{n}\, \mathrm{d}S$, where $\mathbf{I}$ is
the time-averaged intensity vector and $\mathbf{n}$ the outward normal. Two
consequences follow, and between them they are the whole method. First, a
source *outside* the closed surface contributes nothing to the integral: what
enters through one face leaves through another, so a flanking wall radiating
into the same receiving room cancels itself out and only the enclosed specimen
survives. Second, the sign matters: a patch of surface where energy is
flowing back *towards* the specimen subtracts, which is why the standard
carries a minus-sign rule (Clause 6.4.6) that no pressure-based method needs.
The probe reads $\mathbf{I} \cdot \mathbf{n}$ point by point and the operator
performs the integration by moving it, which makes the scan pattern part of
the measurement rather than a matter of technique.

That is what the pressure method cannot do. It reads the transmitted power
*indirectly*, from the receiving-room level and its absorption area, and the
room integrates every watt that arrives whichever path carried it. The
intensity method is therefore the tool of choice when flanking is high
(ISO 15186-1:2000, Clause 1). From the source-room level $L_{p1}$ and the
average normal intensity level $L_{I\mathrm{n}}$ over the surface (area $S_\mathrm{m}$), for a
specimen of area $S$,

$$
R_I = L_{p1} - 6 - \left[ L_{I\mathrm{n}} + 10 \log_{10}\frac{S_\mathrm{m}}{S} \right],
$$

where the $6$ dB is the diffuse-field offset between the sound pressure level
and the incident intensity level. The same formula gives the apparent index
$R'_I$ in the field (ISO 15186-2). The intensity scan measures the transmitted
power directly. The reverberation-room pressure method does not: it infers the
power from the receiving-room level and so *underestimates* it, which makes the
ISO 10140-2 $R$ come out slightly high. The **modified index**
$R_{I,\mathrm{M}} = R_I + K_\mathrm{c}$ adds that same bias back to the intensity result, so an
intensity measurement can be quoted against pressure-method data
(ISO 15186-1, Clause 3.10 NOTE 1). Report $R_I$ when the aim is the true
transmitted power; report $R_{I,\mathrm{M}}$ when the aim is comparability with an
ISO 10140-2 result. Earlier revisions of this guide blamed the bias on the
intensity method itself, which would have called for subtracting $K_\mathrm{c}$, not
adding it. The adaptation term $K_\mathrm{c}$ (Annex B) is $10 \log_{10}(1 + S_{\mathrm{b}2}\lambda/8V_2)$ for a
well-defined room, or the room-independent $10 \log_{10}(1 + 61.4/f)$. The
first form is the Waterhouse boundary-energy term, which makes the second
readable as that same term evaluated at a fixed $S_{\mathrm{b}2}/V_2$. For small
elements the **element normalized level difference** replaces $10\log_{10}(S_\mathrm{m}/S)$
with $10\log_{10}(S_\mathrm{m}/A_0) + 10\log_{10} N$ ($A_0 = 10\ \text{m}^2$, $N$ element units).

```python
import numpy as np
from phonometry import building

# Source-room level Lp1 and the average normal intensity level LIn over the
# measurement surface (Sm), for a specimen of area S; 16 one-third-octave bands.
lp1 = np.full(16, 85.0)
l_in = np.full(16, 40.0)
freqs = [100, 125, 160, 200, 250, 315, 400, 500, 630, 800,
         1000, 1250, 1600, 2000, 2500, 3150]   # nominal 1/3-octave centres
kc = building.adaptation_term_kc(freqs)                  # Annex B (B.2)
res = building.intensity_sound_reduction(lp1, l_in, measurement_area=12.0, area=10.0, kc=kc)
print(round(float(res.r_i[0]), 2))          # 38.21  RI = Lp1 - 6 - [LIn + 10 lg(Sm/S)]
print(round(float(res.r_i_modified[0]), 2)) # 40.29  RI,M = RI + Kc
print(res.rating.rating)                     # 38  ->  RI,w (ISO 717-1 engine)

# Qualify the measurement surface: FpI = Lp - LIn must stay < 10 dB (< 6 dB when
# the receiving side is absorbing); the probe's residual index must exceed FpI+10.
# Lp is the receiving-room pressure level measured over the same surface, if
# possible simultaneously with the scan (Clause 6.4.2). Here it sits 6 dB above
# LIn, i.e. exactly on the absorbing-specimen criterion.
fpi = building.surface_pressure_intensity_indicator(np.full(16, 46.0), l_in)
print(round(float(fpi[0]), 1))               # 6.0

res.plot()   # measured RI vs shifted ISO 717-1 reference (needs matplotlib)
```

![Intensity sound reduction index RI and the Kc-modified index RI,M across the one-third-octave bands, with the Annex B adaptation lift shaded between the two curves](https://docs.jmrp.io/phonometry/media/intensity_insulation.svg)

*The modified index $R_{I,\mathrm{M}} = R_I + K_\mathrm{c}$ lifts $R_I$ (most at the low bands,
where $K_\mathrm{c}$ is largest), so an intensity measurement reproduces the ISO 10140-2
pressure result. The automatic rating is formed only for exactly 16
one-third-octave or 5 octave values.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import building

# A light wall: source-room SPL Lp1 = 85 dB and the measured normal intensity
# level LIn over the Sm = 12 m2 surface, 16 one-third-octave bands.
freqs = [100, 125, 160, 200, 250, 315, 400, 500, 630, 800,
         1000, 1250, 1600, 2000, 2500, 3150]
l_in = np.array([57.8, 61.9, 60.5, 55.6, 55.8, 55.5, 53.4, 51.6,
                 50.2, 47.7, 46.4, 45.7, 44.8, 45.2, 47.2, 52.7])
kc = building.adaptation_term_kc(freqs)           # Annex B adaptation term
res = building.intensity_sound_reduction(np.full(16, 85.0), l_in,
                                         measurement_area=12.0, area=10.0,
                                         kc=kc)

x = np.arange(len(freqs))
fig, ax = plt.subplots()
ax.fill_between(x, res.r_i, res.r_i_modified, alpha=0.2, label="Kc adaptation")
ax.plot(x, res.r_i, "-o", label="RI (intensity)")
ax.plot(x, res.r_i_modified, "--s", label="RI,M = RI + Kc")
ax.set_xticks(x, [str(f) for f in freqs], rotation=45)
ax.set(xlabel="Frequency [Hz]", ylabel="Sound reduction index [dB]",
       title=f"RI,w = {res.rating.rating} dB, RI,M,w = {res.rating_modified.rating} dB")
ax.legend()
plt.show()
```

## Scanning the measurement surface (Clause 6.4)

A method defined by how a probe is moved is not documented by its formula.
Everything below fixes a number that the formula then consumes, and none of it
is checked by the functions on this page.

![Section through a laboratory transmission suite. On the left, the source room with a loudspeaker low in the room, clear of the walls, and five microphone positions spread through the room for the room average Lp1. In the middle, the specimen of ten square metres fills the test opening of the separating wall, flush with its receiving face. On the receiving side a dashed measurement surface forms a shallow box in front of the specimen, its sides as deep as the measurement distance d of 0.1 to 0.3 metres and each side a subarea of its own; for a four by two and a half metre opening at 0.2 metres its area Sm is 12.6 square metres. The front of the box is split into three subareas: a p-p probe held normal to the surface sits on the first, two arrows cross the second outwards, and an arrow points back towards the specimen through the third, whose area enters Formula 11 with a minus sign. Below, one panel draws the two scan patterns, vertical lines and then horizontal lines turned 90 degrees, beside the rules: lines one measurement distance apart, a steady 0.1 to 0.3 metres per second, time per subarea following its area, and the mean of the pair kept only if the two differ by less than 1.0 decibel in every band. A second panel shows ISO 15186-3: microphones less than 50 millimetres from the specimen for LpS, the probe on the measurement surface, an absorber on the wall opposite, the formula with 9 decibels, scans differing by less than 2.0 decibels up to 80 hertz and 1.0 decibel from 100 to 160 hertz, and the thickness limits for an absorbing face of the specimen in the source room. A box at the foot carries the intensity sound reduction index with its 6 decibels and the pressure-intensity indicator limits of 10 and 6 decibels, and three lines give the IEC 61043 class 1 probe, the 10 decibel background test and the plane ISO 15186-2 uses before a whole wall in a building, with its indicator 7 decibels under the residual index, or under 6 decibels for an absorbing element](https://docs.jmrp.io/phonometry/media/diagram_intensity_insulation.svg)

### How the measurement goes

The analyser and its probe have to meet IEC 61043 class 1, with a
pressure-residual intensity index more than 10 dB above the $F_{pI}$ you
expect. Before each use, let the instrument warm up, set both microphones with
a class 0 or class 1 sound calibrator, and measure the residual index on the
residual-intensity testing device. Drive the source room and take $L_{p1}$ as
ISO 140-3 asks. On the receiving side, the measurement surface is the flat
opening of a niche at least 0.1 m deep, and otherwise a box, at a measurement
distance of 0.1 m to 0.3 m. Scan it with the probe normal to the surface and
reading outwards, in lines about one measurement distance apart, at a constant
0.1 m/s to 0.3 m/s, giving each subarea time in proportion to its area. A
negative intensity, or $F_{pI}$ above 10 dB (6 dB for a specimen whose
receiving face absorbs), means moving the surface out by 5 cm to 10 cm before
adding absorption. Scan again with the path turned 90°: the mean of the pair
stands only if the two differ by less than 1.0 dB in every band. With $F_{pI}$
below 10 dB, lower the source by 10 dB: if $F_{pI}$ moves by less than 1 dB,
both levels clear the background by 10 dB. Report $R_I$ to one decimal
beside $F_{pI}$ and the residual index in every band, with $S$, $S_\mathrm{m}$,
the measurement distance and the probe's microphones and spacer.

**The surface (Clause 6.4.1).** The measurement surface totally encloses the
test specimen. A specimen in a niche deeper than 0.1 m is normally measured on
the flat surface of the niche opening; otherwise, and for most small building
elements, the surface is box-shaped. Choose the measurement distance in the
**0.1 m to 0.3 m** band. Below 0.1 m the near field of the vibrating element
makes the intensity change sign repeatedly, so the integral stops converging;
above 0.3 m a box-shaped surface picks up too much of the room.

**Qualifying the surface (Clause 6.4.2).** Measure $L_{I\mathrm{n}}$ and, if possible
simultaneously, the surface-averaged pressure level $L_p$, and form the
surface pressure-intensity indicator $F_{pI} = L_p - L_{I\mathrm{n}}$ (Formula (10)).
The surface fails qualification if the measured intensity is negative, or if
$F_{pI} > 10$ dB for a sound-reflecting specimen or $> 6$ dB for one with an
absorbing surface facing the receiving room. The remedy is **ordered**: first
increase the measurement distance by 5 cm to 10 cm; only if that fails, add
absorption to the receiving room. The criterion applies per scan and per
loudspeaker position, and to the *total* surface, not to individual subareas
(for discrete positions, to the surface average). The standard's rule of thumb
for how much absorption is enough is $S/A < 1.25$, with $S$ the measurement
surface and $A$ the receiving room's absorption area, and the more flanking
there is the larger $A$ has to be.

![The surface pressure-intensity indicator FpI per one-third-octave band from 100 Hz to 3150 Hz, exceeding the 10 dB reflecting-specimen criterion in the three lowest bands and settling at 6.5 dB above 630 Hz, with the 10 dB and 6 dB criterion lines drawn](https://docs.jmrp.io/phonometry/media/intensity_field_indicator.svg)

*Qualification is per band, and it fails where a receiving room is least
absorbent. Here the three lowest bands sit above the 10 dB line, so the surface
is not qualified for a reflecting specimen at all and the scan is not yet a
result; and even the qualified part sits above the 6 dB line, so this surface
could not be used for a specimen with an absorbing face. The remedy is ordered
by the standard: add 5 cm to 10 cm of measurement distance first, and only then
put absorption into the receiving room.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
# `np` and `building` are the imports of the first block above.

freqs = [100, 125, 160, 200, 250, 315, 400, 500, 630, 800,
         1000, 1250, 1600, 2000, 2500, 3150]
l_p = np.array([64.0, 63.0, 61.5, 59.0, 57.5, 56.0, 55.0, 54.0,
                53.0, 52.0, 51.0, 50.5, 50.0, 50.0, 51.0, 55.0])
l_in_q = np.array([51.5, 51.5, 51.0, 49.5, 49.0, 48.0, 47.5, 47.0,
                   46.5, 45.5, 44.5, 44.0, 43.5, 43.5, 44.5, 48.5])
f_pi = building.surface_pressure_intensity_indicator(l_p, l_in_q)
print(int((f_pi > 10.0).sum()), "bands fail the reflecting criterion")   # 3

fig, ax = plt.subplots()
x = np.arange(len(freqs))
ax.fill_between(x, 0.0, f_pi, where=f_pi > 10.0, alpha=0.25,
                label="surface not qualified")
ax.plot(x, f_pi, "-o", label="FpI = Lp - LIn (Formula (10))")
ax.axhline(10.0, ls="--", label="10 dB: reflecting specimen (6.4.2)")
ax.axhline(6.0, ls=":", label="6 dB: absorbing specimen")
ax.set_xticks(x, [str(f) for f in freqs], rotation=45, fontsize=8)
ax.set(xlabel="Frequency [Hz]",
       ylabel="Surface pressure-intensity indicator FpI [dB]")
ax.legend()
plt.show()
```

**The scan (Clause 6.4.3).** Hold the probe **normal** to the surface with its
positive direction pointing outwards, away from the element. Scan in parallel
lines, turning at each edge, with the line spacing normally equal to the
measurement distance and denser where radiation is irregular (leaks). Keep the
scan speed constant between **0.1 m/s and 0.3 m/s**, make the scanning time of
each subarea proportional to its area, and interrupt the measurement when
crossing from one subarea to the next rather than stopping mid-area. Where a
box-shaped surface meets the partition, scan as close to the wall as possible:
that intersection is where radiated power is most easily lost out of the
integral.

**Two scans, not one (Clause 6.4.5).** For each fixed loudspeaker position,
carry out **two complete scans** with the scanning path turned 90° between
them. If they differ by less than 1.0 dB in every band, the result is their
arithmetic average; if any band differs by more, **the measurement is not
valid**: repeat the pair, and if it still fails, change the line density, the
surface or the environment. With several loudspeaker positions, run a
qualifying pair for each and report the arithmetic mean of all scans. With a
moving loudspeaker, each scan takes one complete traverse (at least one for
doors, windows and small elements, two for walls) and the total
scanning/traverse time per pattern is at least 120 s for windows, doors and
small elements and at least 600 s for walls.

**Discrete positions instead (Clause 6.4.4).** Space the positions at roughly
the measurement distance, denser for leaky or inhomogeneous specimens but at
constant distance, follow the grade 2 procedure of ISO 9614-1 and check the
array with its Annex B, and dwell at least 10 s per position. A moving
loudspeaker needs at least two traverses over the complete set of positions
for doors, windows and small elements, and eight for walls.

**Background noise (Clause 6.5).** Both the pressure level and the intensity
level must exceed the background by at least 10 dB. The standard's own test is
elegant: with $F_{pI} < 10$ dB, drop the source level by 10 dB; if $F_{pI}$
moves by less than 1 dB, the requirement is met.

### Combining subareas, and the sign that comes with them

A large or inhomogeneous specimen is scanned as several subareas $S_{\mathrm{m}i}$, and
`subarea_intensity_level` performs the area-weighted energy average of Formula (11)
with $S_\mathrm{m} = \sum_i |S_{\mathrm{m}i}|$ (Formula (12)). Clause 6.4.6 adds the rule with no
counterpart anywhere in the pressure methods: where a subarea's net intensity
points the *wrong way* (energy flowing back towards the test object), a minus
sign goes before that $S_{\mathrm{m}i}$ in Formula (11). Express it by passing that
subarea's area as a negative number; its energy is then subtracted from the
numerator while $S_\mathrm{m}$ keeps the unsigned sum.

```python
# `np` and `building` are the imports of the first block above.

# Three subareas of one 12 m2 surface: the two panes and the frame. The frame
# strip reads a net inward flow, so its area enters Formula (11) negative.
l_in_sub = np.array([
    np.full(16, 41.0),    # 5.0 m2, outward
    np.full(16, 39.0),    # 5.5 m2, outward
    np.full(16, 33.0),    # 1.5 m2, INWARD -> negative area
])
combined = building.subarea_intensity_level(l_in_sub, [5.0, 5.5, -1.5])
l_in_comb, s_m = combined.levels, combined.measurement_area
print(round(float(l_in_comb[0]), 2), s_m)     # 39.36 12.0

# Ignoring the sign inflates the transmitted power, i.e. lowers RI:
l_in_naive = building.subarea_intensity_level(l_in_sub, [5.0, 5.5, 1.5]).levels
print(round(float(l_in_naive[0] - l_in_comb[0]), 2))   # 0.24
```

A subarea reading inward is not a curiosity to be signed away. It means the
enclosing surface is cutting through the field of something *outside* it (a
flanking element, a second source in the receiving room), so the qualification
of Clause 6.4.2 should be re-checked before the number is reported at all.
$S_\mathrm{m}$ keeps the unsigned area because it is the area actually scanned, which
is what the $10\log_{10}(S_\mathrm{m}/S)$ term of $R_I$ needs.

### `intensity_sound_reduction()` / `adaptation_term_kc()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `lp1` | 1D or 2D array | dB | one/band, or `(positions, bands)` | Source-room sound pressure level |
| `l_in` | 1D or 2D array | dB | one/band, or `(positions, bands)` | Normal intensity level over the surface |
| `measurement_area` | float | m² | > 0 | Measurement-surface area $S_\mathrm{m}$ |
| `area` | float | m² | > 0 | Specimen area $S$ |
| `kc` | 1D array | dB | one per band / `None` | Adaptation term for the modified index |
| `frequencies` | 1D array | Hz | > 0 | Midband frequencies (`adaptation_term_kc`) |
| `boundary_area` / `volume` | float | m² / m³ | > 0, both or neither | Room $S_{\mathrm{b}2}$ / $V_2$ for Formula (B.1) |
| `n` | int | element units | ≥ 1, default `1` | Number of identical elements (`intensity_element_normalized_difference` only) |

`intensity_sound_reduction()` returns an `IntensityReductionResult` (`r_i`,
`r_i_modified`, `rating`, `rating_modified`);
`intensity_element_normalized_difference()` an
`IntensityElementNormalizedResult` (`d_i_n_e`, `rating`);
`surface_pressure_intensity_indicator()` returns an array and
`subarea_intensity_level()` a `SubareaIntensityLevel` (`levels`, `measurement_area`). The `rating` fields are formed only
for exactly 16 one-third-octave or 5 octave values and are `None` otherwise,
so a scan taken over the full ISO 15186-1 range of 100 Hz to 5000 Hz
(Clause 6.6, 18 bands) must be trimmed to the ISO 717-1 range before it can be
rated.

## ISO 15186-1 intensity test report (`.report()`)

`IntensityReductionResult.report()` writes the one-page ISO 15186-1:2000 test
report of the intensity sound reduction index $R_I$, reusing the same
accredited two-panel layout as the ISO 10140 and ISO 16283 fiches. Because
$R_I$ is an ordinary sound reduction index, its single-number rating $R_{I,\mathrm{w}}$
is the ISO 717-1 airborne rating evaluated on the intensity spectrum: the fiche
names ISO 15186-1 in its basis line, tabulates $R_I$ to one decimal place
beside the measured-versus-shifted-reference curve, boxes `RI,w (C; Ctr)` and
prints the statement that the transmitted sound power was measured directly
over the measurement surface. `verbose=True` annexes the $K_\mathrm{c}$-modified index
$R_{I,\mathrm{M}}$ (Formula (9)) beside $R_I$ when an adaptation term was supplied.

The applicable `ReportMetadata` fields describe the intensity measurement:
`specimen` (the tested element), `area` (specimen area $S$), `client`,
`manufacturer`, `test_room`, `laboratory`, `operator`, `report_id` and
`test_date`, plus the room/climate fields shared with the other insulation
fiches. There is no dedicated field for the measurement-surface geometry or the
scanning-versus-discrete-point acquisition method; record those in `notes` and
name the standard in `measurement_standard` (`"ISO 15186-1"`). The requirement
verdict, `language="es"` and the `phonometry[report]` extra behave exactly as
in the sibling fiches.

```python
import numpy as np
from phonometry import building, ReportMetadata

freqs = np.array([100, 125, 160, 200, 250, 315, 400, 500, 630, 800,
                  1000, 1250, 1600, 2000, 2500, 3150], dtype=float)
lp1, sm, s = 85.0, 12.0, 10.0
l_in = np.array([57.8, 61.9, 60.5, 55.6, 55.8, 55.5, 53.4, 51.6,
                 50.2, 47.7, 46.4, 45.7, 44.8, 45.2, 47.2, 52.7])
kc = building.adaptation_term_kc(freqs)                 # Annex B, Formula (B.2)
res = building.intensity_sound_reduction(
    np.full(16, lp1), l_in, measurement_area=sm, area=s, kc=kc
)
metadata = ReportMetadata(
    specimen="100 mm autoclaved aerated concrete block wall",
    area=10.0, measurement_standard="ISO 15186-1",
    test_room="Transmission suite (example)",
    laboratory="Phonometry Reference Laboratory",
    report_id="PHN-2026-0150",
    requirement=30.0,                                   # RI,w >= 30 dB -> PASS
)
res.report("RIw.pdf", metadata=metadata)                # RI,w (C; Ctr)
res.report("RIw_kc.pdf", metadata=metadata, verbose=True)  # f | RI | RI,M
```

The example fiche is regenerated with `make reports` and kept in the
repository. Click the preview to open the PDF:

**Report:** [Intensity ISO 15186-1 example report (PDF)](https://docs.jmrp.io/phonometry/media/iso15186_intensity_example.pdf): One-page laboratory intensity sound insulation test report of a building element: the metadata header (client, specimen description, mounting, sample area, room volumes, climate), the one-third-octave RI table beside the measured-versus-shifted-reference curve, the boxed RI,w (C; Ctr) rating evaluated per ISO 717-1, the intensity-method statement and a PASS verdict against the 30 dB requirement.

Intensity fiche (IntensityReductionResult.report), RI,w (C; Ctr).

## Small building elements: the element-normalized level difference

For a **small building element** (a ventilator, a socket, a small window) the
intensity method reports the element-normalized level difference $D_{I,\mathrm{n,e}}$
(Formula (8)) instead, normalized to the reference absorption area
$A_0 = 10\ \text{m}^2$. `IntensityElementNormalizedResult.report()` writes the
same one-page fiche through the shared renderer, boxing `DI,n,e,w (C; Ctr)`
rated per ISO 717-1; `verbose=True` shows the ISO 717 evaluation per band and a
`requirement` adds a PASS/FAIL verdict (the element insulation passes at or
above the target).

```python
import numpy as np
from phonometry import building, ReportMetadata

lp1, sm, n = 85.0, 12.0, 1                              # source SPL, surface, units
l_in = np.array([57.9, 62.0, 60.6, 55.7, 55.9, 55.6, 53.5, 51.7,
                 50.3, 47.8, 46.5, 45.8, 44.9, 45.3, 47.3, 52.8])
res = building.intensity_element_normalized_difference(
    np.full(16, lp1), l_in, measurement_area=sm, n=n
)
res.plot()   # DI,n,e vs shifted ISO 717-1 reference (needs matplotlib)
metadata = ReportMetadata(
    specimen="Trickle ventilator in a 100 mm masonry wall",
    measurement_standard="ISO 15186-1",
    laboratory="Phonometry Reference Laboratory",
    report_id="PHN-2026-0151",
    requirement=30.0,                                   # DI,n,e,w >= 30 dB -> PASS
)
res.report("DIne.pdf", metadata=metadata)               # DI,n,e,w (C; Ctr)
```

![Element-normalized level difference DI,n,e of a trickle ventilator per one-third-octave band against the shifted ISO 717-1 reference curve, with the unfavourable deviations shaded and the DI,n,e,w rating annotated](https://docs.jmrp.io/phonometry/media/intensity_element_insulation.svg)

*The small element is rated exactly like a wall: $D_{I,\mathrm{n,e}}$ feeds the
ISO 717-1 engine and the unfavourable deviations (reference above the
measurement) set $D_{I,\mathrm{n,e,w}}$. The $10\log_{10}(S_\mathrm{m}/A_0)$ normalization replaces
the specimen-area term, so the number describes the element irrespective of
the wall it sits in.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import building

# A trickle ventilator in a masonry wall: source-room SPL 85 dB and the
# normal intensity level over the Sm = 12 m2 measurement surface.
l_in = np.array([57.9, 62.0, 60.6, 55.7, 55.9, 55.6, 53.5, 51.7,
                 50.3, 47.8, 46.5, 45.8, 44.9, 45.3, 47.3, 52.8])
res = building.intensity_element_normalized_difference(
    np.full(16, 85.0), l_in, measurement_area=12.0, n=1
)

# One line — DI,n,e vs the shifted ISO 717-1 reference:
res.plot()
plt.show()

# By hand, from the rating the result carries:
w = res.rating
fig, ax = plt.subplots()
ax.semilogx(w.frequencies, res.d_i_n_e, "o-", label="DI,n,e (element)")
ax.semilogx(w.frequencies, w.shifted_reference, "s--",
            label="shifted reference")
ax.fill_between(w.frequencies, w.measured, w.shifted_reference,
                where=w.measured < w.shifted_reference, interpolate=True,
                alpha=0.3, label="unfavourable deviations")
ax.set_xlabel("Frequency [Hz]")
ax.set_ylabel("Element normalized level difference [dB]")
ax.set_title(f"DI,n,e,w = {w.rating} dB  (C={w.c:+d}; Ctr={w.ctr:+d})")
ax.legend()
plt.show()
```

**Report:** [Intensity ISO 15186-1 element example report (PDF)](https://docs.jmrp.io/phonometry/media/iso15186_element_example.pdf): One-page laboratory element-normalized sound intensity insulation test report of a small building element: the metadata header (client, specimen description, mounting, element area), the one-third-octave DI,n,e table beside the measured-versus-shifted-reference curve, the boxed DI,n,e,w (C; Ctr) rating evaluated per ISO 717-1, the intensity-method statement and a PASS verdict against the 30 dB requirement.

Element intensity fiche (IntensityElementNormalizedResult.report), DI,n,e,w (C; Ctr).

## Laboratory or field (ISO 15186-2)

Part 1 is a laboratory method: the specimen sits in a test opening between
two rooms, and the suppressed flanking of the facility makes $R_I$ a
property of the element. ISO 15186-2 takes the same probe, the same surface
scan and the same formula into the finished building, where the result is
the apparent index $R'_I$ of the installed element, flanking radiation and
all. The selectivity that motivated the method in the laboratory doubles in
the field: because the probe reads only what its measurement surface
radiates, partial surfaces isolate which element (the wall itself, a window,
a leaky junction) carries the transmitted power, which no pressure-based
field method can resolve. Qualify each scan with the same
pressure-intensity indicator, and expect the probe's own limits (the
[spacer phase error](https://docs.jmrp.io/phonometry/devices/emission/intensity/)) to set the usable
low-frequency range.

## Low frequencies: the pressure on the specimen (ISO 15186-3)

Both parts above put the source microphone in the *room*, and below 100 Hz
that is exactly where a source room stops being able to answer. A room a
laboratory can build has too few modes down there for a space average to
describe the field driving the specimen: move the microphones and the average
moves with them. ISO 15186-3 keeps the intensity probe on the receiving side
and changes the other end of the measurement: the source-room level is read
**on the surface of the test specimen itself**, from fixed microphones no more
than 50 mm from it (Clause 6.3):

$$
R_I = L_{p\mathrm{S}} - 9 - \left[ L_{I\mathrm{n}} + 10\lg\frac{S_\mathrm{m}}{S} \right]\ \mathrm{dB}
$$

**Nine decibels, not six.** That single constant is the whole difference from
Part 1. Close to a rigid boundary a diffuse field carries twice the
mean-square pressure it carries away from one, so a microphone 50 mm from the
specimen reads 3 dB above the room average of the same field. Part 1's room
average carries no such build-up and subtracts 6; the surface average carries
it and subtracts 9. Everything else in the formula (the measurement-surface
area ratio, the sign of the intensity, the subarea combination) is the method
you already have.

The price is a validity condition Part 1 does not have. The doubling is only
3 dB if the surface reflects, so a NOTE under Formula (7) restricts it: the
formula holds for a specimen with a reflecting surface in the source room,
still works for moderately absorbing ones (100 mm of porous absorber), should
be read only from 50 Hz to 80 Hz behind 100 mm to 200 mm of absorber, and is
not valid behind anything thicker. Nothing in the library can see the
specimen, so this one is on you.

**How many microphones (Clause 6.3).** Distributed evenly but
*asymmetrically* over the whole surface, edges and corners included, at least
30 s of integration each:

| Test specimen | Minimum fixed microphone positions |
| :--- | :--- |
| Small building elements (ISO 140-10) | 2 for each element mounted in the test wall |
| Other elements up to 3 m² | 6 |
| Others | 12 |

**The bands.** Clause 6.6 requires filters at 50 Hz, 63 Hz and 80 Hz and
allows 100 Hz, 125 Hz and 160 Hz to be added; the ceiling itself is Clause
1.1's, which applies this part over 50 Hz to 160 Hz and says it is mainly
intended for 50 Hz to 80 Hz. Six bands is the whole method, which is why no
single-number rating comes out of it; ISO 717-1 needs sixteen. Passing a band
outside that range is refused rather than extrapolated, and Clause 1.1 says
what to do instead: combine these results with ISO 140-3 and ISO 15186-1 into
one curve over 50 Hz to 5000 Hz.

**Qualifying the surface (Clause 6.4.2).** The indicator is the same
$F_{pI} = L_p - L_{I\mathrm{n}}$ as everywhere else in the series, and both of its
levels are read on the measurement surface in the *receiving* room; it is not
the surface level Formula (7) is built from. The limits distinguish the
specimen, not the room: $F_{pI} > 10$ dB refuses a sound-reflecting specimen and
$F_{pI} > 6$ dB one that presents a sound-absorbing surface in the receiving
room, which is the two-absorbing-sides case, since a specimen absorbing on one
side is mounted with that side towards the source (Clause 5.3). The receiving
room always has an efficient absorber on the wall opposite the specimen; that
is a facility requirement, not a case. Clause 6.5 adds the 10 dB background
margin and its own test: with $F_{pI} < 10$ dB, drop the source by 10 dB, and if
$F_{pI}$ moves by less than 1 dB the requirement is met.

Because the standard only asks for that second pressure measurement "if
possible", `l_p` is optional here. Without it there is no indicator and no
verdict, and the result says so rather than guessing:

```python
import numpy as np
from phonometry import building

# A light partition, 10 m2, scanned over a 12.6 m2 box surface. LpS is the
# average over the surface of the specimen in the source room; LIn and Lp are
# read together on the measurement surface in the receiving room.
freqs = [50.0, 63.0, 80.0, 100.0, 125.0, 160.0]
lp_surface = np.array([88.4, 89.1, 90.3, 91.0, 91.4, 91.8])
l_in = np.array([61.6, 60.9, 59.8, 57.9, 56.0, 53.9])
l_p = np.array([74.0, 72.0, 69.4, 66.1, 63.1, 60.3])

res = building.low_frequency_intensity_reduction(
    lp_surface, l_in, measurement_area=12.6, area=10.0,
    l_p=l_p, frequencies=freqs,
)
print(np.round(res.r_i, 1))                       # [16.8 18.2 20.5 23.1 25.4 27.9]
print(np.round(res.surface_pressure_intensity_indicator, 1))  # [12.4 11.1  9.6  8.2  7.1  6.4]
print(res.qualified.tolist())   # [False, False, True, True, True, True]
print(res.indicator_limit)      # 10.0

# Without the receiving-side pressure there is no Clause 6.4.2 answer at all.
bare = building.low_frequency_intensity_reduction(
    lp_surface, l_in, measurement_area=12.6, area=10.0, frequencies=freqs,
)
print(bare.surface_pressure_intensity_indicator, bare.qualified)   # None None
```

A refused band is flagged, not dropped. The standard's answer to
$F_{pI}$ over the limit is to improve the measurement environment: increase the
measurement distance by 5 cm to 10 cm first, then reduce flanking or improve
the absorber opposite. That is why the index is still computed and the verdict
travels beside it.

![Left: the low-frequency intensity sound reduction index per one-third-octave band from 50 Hz to 160 Hz as bars, with the 50 Hz and 63 Hz bands hatched because their surface pressure-intensity indicator exceeds 10 dB, and the indicator drawn as a curve on a twin axis against its 10 dB limit line. Right: the calculated limp-panel sound reduction index of Annex A with the 4 dB tolerance the annex allows shaded around it and a measured curve staying inside](https://docs.jmrp.io/phonometry/media/low_frequency_intensity.svg)

*Left, the measurement: the index rises through the six bands while the
indicator falls past its limit, so the two lowest bands are computed but not
qualified. Right, the facility: Annex A's calculated limp-panel curve and the
4 dB either side of it that a measurement has to stay within.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt

# res is the LowFrequencyIntensityResult computed above. One line:
res.plot()   # RI bars, refused bands hatched, FpI and its limit on a twin axis
plt.show()

# By hand, and the Annex A panel beside it.
calculated = building.limp_panel_reduction_index(
    freqs, surface_mass=10.0, area=10.0, temperature_c=23.0,
)
measured = calculated + np.array([2.6, -1.8, 1.1, -2.9, 0.7, -1.4])
x = np.arange(len(freqs))
fig, (axl, axr) = plt.subplots(1, 2, figsize=(13.0, 5.6))
bars = axl.bar(x, res.r_i, width=0.68)
for bar, ok in zip(bars, res.qualified, strict=True):
    if not ok:
        bar.set_hatch("///")
axl.set_xticks(x, [f"{f:g}" for f in freqs])
axl.set(xlabel="Frequency [Hz]", ylabel="Sound reduction index [dB]")
twin = axl.twinx()
twin.plot(x, res.surface_pressure_intensity_indicator, "-o", color="#2ca02c", label="FpI")
twin.axhline(res.indicator_limit, ls="--", color="#d62728", label="FpI limit")
twin.set_ylabel("Surface pressure-intensity indicator [dB]")
twin.legend()
axr.fill_between(x, calculated - 4.0, calculated + 4.0, alpha=0.2,
                 label="4.0 dB tolerance (Annex A)")
axr.plot(x, calculated, "-o", label="calculated (A.1)")
axr.plot(x, measured, "--s", label="measured")
axr.set_xticks(x, [f"{f:g}" for f in freqs])
axr.set(xlabel="Frequency [Hz]", ylabel="Sound reduction index [dB]")
axr.legend()
plt.show()
```

### Small elements at low frequencies, and a sign the series disagrees on

Formula (8) normalizes a small element to the reference absorption area
$A_0 = 10$ m² exactly as Part 1 does, with the 9 dB of the surface measurement
in place of 6:

$$
D_{I\mathrm{n,e}} = L_{p\mathrm{S}} - 9 - \left[ L_{I\mathrm{n}} - 10\lg\frac{A_0}{S_\mathrm{m}} - 10\lg N \right]\ \mathrm{dB}
$$

Read the bracket carefully. The $10\lg N$ inside it is *subtracted*, so the term
reaches $D_{I\mathrm{n,e}}$ **added**, which is the sign this library derives, and the
opposite of what ISO 15186-1 prints for the same quantity. Two parts of one
series print the two signs; this is the one that agrees with the physics
(installing $N$ units raises the transmitted power by $10\lg N$, so recovering
the per-unit figure has to add it back) and with the pressure-based
ISO 10140-2 Formula (6). The Part 1 print is registered in
[ERRATA](https://docs.jmrp.io/phonometry/reference/errata/), and Part 1's implementation warns
whenever $N > 1$ puts it at odds with its own page. Nothing warns here,
because here the page and the physics agree.

```python
# Four identical trickle ventilators inside one 2.0 m2 measurement surface.
element = building.low_frequency_element_normalized_difference(
    np.full(6, 90.0), np.array([62.0, 61.0, 60.0, 58.0, 57.0, 55.0]),
    measurement_area=2.0, n_elements=4, frequencies=freqs,
)
print(np.round(element.d_i_n_e, 1))     # [32. 33. 34. 36. 37. 39.]
print(element.n_elements)                 # 4
```

### Qualifying the facility (Annex A)

Annex A is normative, and it is what a laboratory does before it reports
anything: measure a limp panel of more than 1 m², calculate what it should
read, and require the two to agree within **4.0 dB** from 50 Hz to 160 Hz. The
calculated half is forced transmission and nothing else: mass law reduced by
the radiation efficiency of a plate driven by a diffuse field:

$$
R = R_0 - 10\lg 2\sigma_\mathrm{d}, \qquad
R_0 = 20\lg\frac{\pi f m}{\rho c}, \qquad
\sigma_\mathrm{d} = \tfrac{1}{2}\left[0.20 + \ln\left(2\pi\frac{f}{c}\sqrt{S}\right)\right]
$$

with the air taken at the climate of the test,
$\rho c = 427\sqrt{273/(273+\theta)}\cdot B/B_0$ and $c = 331 + 0.6\,\theta$.
The panel is limp *by assumption*. The 160 Hz ceiling is not the annex's own:
Clause 1.1 applies the whole of this part over 50 Hz to 160 Hz, and says it is
mainly intended for 50 Hz to 80 Hz.

```python
# Annex A, Table A.1: 12.5 mm plaster board, 10 kg/m2, over a 10 m2 opening,
# at 1 013 hPa and 23 degC.
calc = building.limp_panel_reduction_index(
    freqs, surface_mass=10.0, area=10.0,
    temperature_c=23.0, static_pressure_pa=101300.0,
)
print(np.round(calc, 1))    # [10.7 11.9 13.4 14.8 16.3 17.9]
```

Those six values are the printed table, band for band, and they are the
conformance anchor for all five formulas. The steel-sandwich column beside
them in the same table is not: no reading of the inputs printed next to it
reproduces it, and the one that would takes an area and a surface mass moved
together, the mass landing heavier than solid steel of the stated thickness. It
is registered in [ERRATA](https://docs.jmrp.io/phonometry/reference/errata/) and is deliberately
not used as an oracle.

### `low_frequency_intensity_reduction()`, `low_frequency_element_normalized_difference()` and `limp_panel_reduction_index()` parameters

| Parameter | Type | Units | Range / default | Notes |
| :--- | :--- | :--- | :--- | :--- |
| `lp_surface` | 1D or 2D array | dB | one/band, or `(positions, bands)` | Pressure over the surface of the specimen, $L_{p\mathrm{S}}$ |
| `l_in` | 1D or 2D array | dB | one/band, or `(positions, bands)` | Normal intensity level over the measurement surface |
| `measurement_area` | float | m² | > 0 | Measurement-surface area $S_\mathrm{m}$ |
| `area` | float | m² | > 0 | Specimen area $S$; the limp panel of Annex A needs $S \\geq 1$ m² |
| `l_p` | 1D or 2D array | dB | one/band / `None` | Receiving-side pressure on the measurement surface, for Formula (5) |
| `frequencies` | 1D array | Hz | 50 to 160 / `None` | Mid-band frequencies; Clause 6.6 admits no others |
| `absorbing_specimen_surface` | bool | — | default `False` | `True` tightens the Clause 6.4.2 limit to 6 dB |
| `n_elements` | int | element units | ≥ 1, default `1` | Number $N$ of units (`low_frequency_element_normalized_difference` only) |
| `surface_mass` | float | kg/m² | > 0 | Limp-panel surface mass $m$ (`limp_panel_reduction_index`) |
| `temperature_c` / `static_pressure_pa` | float | °C / Pa | default 23 °C, 101 300 Pa | The climate of Formulas (A.4) and (A.5) |

`low_frequency_intensity_reduction()` returns a `LowFrequencyIntensityResult`
(`r_i`, `surface_pressure_intensity_indicator`, `qualified`,
`indicator_limit`), `low_frequency_element_normalized_difference()` a
`LowFrequencyElementResult` (`d_i_n_e` and the same three), and
`limp_panel_reduction_index()` a plain array. Neither result carries a rating:
Clause 7 asks for the index to one decimal beside the indicator, and six bands
cannot feed ISO 717-1.

## What this guide covers

- **Covered.** ISO 15186-1:2000's intensity sound reduction index $R_I$ (Clause 3.8), its
  $K_\mathrm{c}$-modified $R_{I,\mathrm{M}}$ (Annex B) and the element-normalized $D_{I,\mathrm{n,e}}$
  (Clause 3.9), with the subarea combination of Formulas (11)-(12) and the
  surface pressure-intensity indicator, via
  `building.intensity_sound_reduction`, `building.adaptation_term_kc`,
  `building.intensity_element_normalized_difference`,
  `building.surface_pressure_intensity_indicator` and
  `building.subarea_intensity_level`; the single-number ratings reuse the verified ISO
  717-1 engine, and both results write the one-page test fiche through
  `.report()`. ISO 15186-3:2002's low-frequency variant is covered too: the
  surface-pressure index $R_I$ of Formula (7), the element-normalized
  $D_{I\mathrm{n,e}}$ of Formula (8), the Clause 6.4.2 qualification against both of
  its limits, the Clause 6.6 band range and the normative limp-panel
  qualification of Annex A, via `building.low_frequency_intensity_reduction`,
  `building.low_frequency_element_normalized_difference` and
  `building.limp_panel_reduction_index`.

- **Not covered.** The sound-intensity measurement itself (the scanning probe, the two-microphone
  acquisition and phase-mismatch calibration behind $L_{p1}$ and $L_{I\mathrm{n}}$) is
  not implemented: both levels are taken as already-measured inputs, and the ISO
  15186-1 report fiche states explicitly that it has no field for the
  measurement-surface geometry or the scanning-versus-discrete-point acquisition
  method. Nothing here enforces the Clause 6.4 acquisition documented above
  either (the 0.1–0.3 m stand-off, the 0.1–0.3 m/s scan speed, the 90°-rotated
  second scan and its 1.0 dB validity test, the 10 dB background margin), so a
  single scan will produce a number just as readily as a qualified pair. ISO
  15186-2's own field procedure (loudspeaker positions, the façade cases) is not
  implemented either: the formulas here apply unchanged to field data, but
  nothing checks how that data was acquired. The same holds of Part 3's
  procedure: the microphone counts of its Table 1, the 50 mm stand-off, the two
  90°-rotated scans and their 2.0 dB / 1.0 dB agreement test, the 10 dB
  background margin and the source-room absorption limits under Formula (7) are
  documented above and enforced nowhere. Part 3 results carry no single-number
  rating and no `.report()` fiche, because six bands cannot feed ISO 717-1 and
  the standard's Clause 8 report has no worked form here.

## See also

- [Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/):
  the ISO 10140 pressure method that the $K_\mathrm{c}$ adaptation reproduces.
- [Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/):
  the pressure-based field quantities and their single-number ratings.
- [Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/):
  the reference-curve engine behind $R_{I,\mathrm{w}}$ and $D_{I,\mathrm{n,e,w}}$.
- [Sound Intensity](https://docs.jmrp.io/phonometry/devices/emission/intensity/): the two-microphone
  probe, its field indicators and the residual-index qualification behind
  every scan.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/): the
  reference-curve derivation behind the weighted single-number ratings.
- API reference: [`building.measurement.intensity_insulation`](https://docs.jmrp.io/phonometry/reference/api/building/intensity-insulation/).

## References

- **Hopkins, C. (2007).** *Sound insulation*. Butterworth-Heinemann. https://doi.org/10.4324/9780080550473
  The reference monograph for laboratory sound-insulation measurement, including the intensity route and its relation to the pressure methods. ISBN 978-0-7506-6526-1.
- **International Organization for Standardization. (2000).** [*Acoustics — Measurement of sound insulation in buildings and of building elements using sound intensity — Part 1: Laboratory measurements*](https://www.iso.org/standard/26097.html) (ISO 15186-1:2000).
  The sound-intensity sound reduction index R_I, its Kc-modified form and the element normalized level difference (laboratory); the tool of choice when flanking is high (Clause 1).
- **International Organization for Standardization. (2002).** [*Acoustics — Measurement of sound insulation in buildings and of building elements using sound intensity — Part 3: Laboratory measurements at low frequencies*](https://www.iso.org/standard/31395.html) (ISO 15186-3:2002).
  The low-frequency variant: the source-room level is read on the surface of the specimen and 9 dB is subtracted instead of 6 (Clause 3.8), with the normative limp-panel qualification of Annex A.
- **International Organization for Standardization. (2003).** [*Acoustics — Measurement of sound insulation in buildings and of building elements using sound intensity — Part 2: Field measurements*](https://www.iso.org/standard/30105.html) (ISO 15186-2:2003).
  The field counterpart of the intensity method, giving the apparent index R'\_I.
- **International Organization for Standardization. (2020).** [*Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation*](https://www.iso.org/standard/77435.html) (ISO 717-1:2020).
  The reference-curve rating behind R_I,w (C; Ctr) and D_I,n,e,w, which Part 3's six bands cannot feed; implemented in the insulation ratings guide.
