# Sound insulation

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/insulation/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/insulation/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-16
Updated: 2026-10-06T02:25:32Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Airborne and impact insulation measured and rated: laboratory (ISO 10140, 15186, 10848), field (ISO 16283, 10052, 16032), ISO 717 ratings and façades.

---

Sound insulation has a life cycle, and the pages of this section follow it.
An element (a wall build-up, a floating floor, a window) is first
characterised **in the laboratory**, where suppressed flanking isolates its
direct transmission. That laboratory data feeds a **prediction** of how a
whole building will perform, flanking paths included. The finished building is
then **verified in the field**. At every stage the band spectrum is collapsed
to the **single number** regulations quote, and for almost everything that
collapse is one shared reference-curve engine rather than a step of any single
method. The exception is the heavy-impact rating of ISO 717-2 Annex D, which
shifts no curve at all: it sums A-weighted band levels in energy.

**Laboratory.**
[Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/) covers
the ISO 10140 sound reduction index and normalized impact level with their
background-noise correction, and
[Linings, Floor Coverings, Joints and Rain (ISO 10140-1)](https://docs.jmrp.io/phonometry/buildings/insulation/lab-application-rules/)
what four of its application rules do with them: the improvement a lining
or a floor covering gives the element it is laid on, rated on the reference
curves of ISO 717, the sound reduction index of a sealed joint per metre, and
the sound of artificial rain on a roof. Two laboratory
methods sit beside it:
[Sound Insulation by Intensity (ISO 15186)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-intensity/)
reads the transmitted power off the radiating face when flanking is too high
for the pressure method, and
[Laboratory Flanking Transmission (ISO 10848)](https://docs.jmrp.io/phonometry/buildings/insulation/flanking-lab/)
measures the junction data the prediction consumes. A third, the
floor-covering improvement of ISO 16251-1, is filed with the design pages it
feeds.

**Prediction.** The design-stage half has a section of its own,
[Insulation design](https://docs.jmrp.io/phonometry/buildings/design/): the
EN 12354 flanking model between rooms, the theoretical insulation of a panel,
and the two material measurements a floor design consumes.

**Field.**
[Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/)
covers the engineering-grade airborne and impact measurement in the building,
its Clause 14 test report and the ISO 12999-1 uncertainty that qualifies it.
Below 25 m³, to the nearest cubic metre, the same standard makes a second,
corner-based measurement
mandatory in the three lowest bands, and
[Small Rooms: the ISO 16283 Low-Frequency Procedure](https://docs.jmrp.io/phonometry/buildings/insulation/low-frequency-procedure/)
is that procedure in full, shared by all three parts (Part 3 confines it to
its loudspeaker methods; the road-traffic method keeps the default procedure).
The same standard specifies two more impact sources, a rubber ball and a bang
machine, for the slow low-frequency thumps a tapping machine says nothing
about;
[Heavy and Soft Impact Sources (ISO 16283-2)](https://docs.jmrp.io/phonometry/buildings/insulation/heavy-impact-sources/)
covers their specification, the Fast-weighted standardization of the maximum
level and the Annex D rating.
When the question does not deserve that effort,
[Sound Insulation Survey Method (ISO 10052)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-survey/)
trades accuracy for speed with octave bands and a reverberation index.
The same field work measures the sound the building's own equipment makes in
its rooms, and ISO 10052 has a survey quantity for it; the engineering method
is
[Service-Equipment and Activity Noise (ISO 16032)](https://docs.jmrp.io/phonometry/buildings/insulation/service-equipment-noise/),
implemented from the draft of its second edition, which adds activities such
as a bar or a sports hall to the installed equipment.

**Ratings and the envelope.**
[Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/) is the
reference-curve engine every one of those methods ends on, with its spectrum
adaptation terms C, Ctr and CI. And
[Façade Sound Insulation](https://docs.jmrp.io/phonometry/buildings/insulation/facade-insulation/) keeps the
building envelope in one place: measured per ISO 16283-3, predicted per
EN 12354-3, and radiating outwards per EN 12354-4. National building codes
restate those ratings in their own global quantities, and
[Spanish Building Code (CTE DB-HR)](https://docs.jmrp.io/phonometry/buildings/insulation/spanish-building-code/)
implements the Spanish one: the direct Annex A index over eighteen bands, the
clause 2 requirement tables and the window-size correction.

Two neighbouring sections complete the picture: the room-side quantities
(reverberation time, absorption) live in
[Room acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/), and the
structure-borne noise of building *equipment*, predicted by the closely
related EN 12354-5, lives in
[Structure-borne sources](https://docs.jmrp.io/phonometry/vibration/structural/).

## Pages in this section

- [Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/):
  ISO 16283-1/2 field measurement, its test report and the ISO 12999-1
  uncertainty.
- [Small Rooms: the ISO 16283 Low-Frequency Procedure](https://docs.jmrp.io/phonometry/buildings/insulation/low-frequency-procedure/):
  the 25 m³ trigger, the corner level of Formula (12), the Formula (13)
  combination and the 63 Hz octave reverberation time of Clause 10.4
  (Clause 8.4 in Part 3).
- [Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/):
  the ISO 10140 characterisation of an element with flanking suppressed.
- [Linings, Floor Coverings, Joints and Rain (ISO 10140-1)](https://docs.jmrp.io/phonometry/buildings/insulation/lab-application-rules/):
  the improvement ΔR of a lining and ΔL of a floor covering on their reference
  elements, lightweight floors included, with the form of Figure H.4, the sound
  reduction index of a sealed joint per metre with the form of Figure J.7, and
  the sound intensity level of artificial rain (Annexes G, H, J and K).
- [Sound Insulation by Intensity (ISO 15186)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-intensity/):
  the ISO 15186-1/-2 direct-power route to the same indices.
- [Sound Insulation Survey Method (ISO 10052)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-survey/):
  the octave-band control method, its reverberation index and its survey
  quantities.
- [Service-Equipment and Activity Noise (ISO 16032)](https://docs.jmrp.io/phonometry/buildings/insulation/service-equipment-noise/):
  the engineering method for the sound of taps, lifts, ventilation and
  activities in a room, from the ISO/DIS 16032:2023 draft: positions,
  background, standardization and the Table 1 single numbers.
- [Laboratory Flanking Transmission (ISO 10848)](https://docs.jmrp.io/phonometry/buildings/insulation/flanking-lab/):
  the measured vibration reduction index Kij, the flanking descriptors Dn,f
  and Ln,f, and the suspended-ceiling plenum path with its normalized ceiling
  attenuation Dn,c and ceiling attenuation class.
- [Heavy and Soft Impact Sources (ISO 16283-2)](https://docs.jmrp.io/phonometry/buildings/insulation/heavy-impact-sources/):
  the rubber ball and the bang machine, the impact force exposure levels that
  specify them, the Fast-weighted maximum level and the ISO 717-2 Annex D
  single number.
- [Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/):
  the ISO 717-1/-2 reference-curve engines, C, Ctr and CI, the enlarged-range
  terms and the ISO 717 fiche.
- [Façade Sound Insulation](https://docs.jmrp.io/phonometry/buildings/insulation/facade-insulation/):
  the envelope measured (ISO 16283-3), predicted (EN 12354-3) and radiating
  outwards (EN 12354-4).
- [Spanish Building Code (CTE DB-HR)](https://docs.jmrp.io/phonometry/buildings/insulation/spanish-building-code/):
  the DB-HR global indices RA, RA,tr, DnT,A and D2m,nT,Atr, the clause 2
  requirements and the window-size correction.

## What this section does not cover

- **Not covered.** **The library starts after the microphone.** The field, laboratory, survey and
  intensity routines that form an insulation index accept per-position spectra
  and energy-average them for you; the heavy-impact standardization, the
  flanking indices, the ISO 717 ratings and the background-noise helpers take
  their per-band input already formed. Either way, nothing verifies how the
  measurement was made: not the number and placement of the source and
  microphone positions behind those spectra, not the corner positions the
  ISO 16283 low-frequency procedure is fed from, and not the test-facility and
  mounting requirements of ISO 10140-1. Those are the operator's
  responsibility and the report's, and
  they are what makes the numbers here mean something. The one method that
  checks its own positions is the ISO 16032 engineering
  method for service-equipment noise, with the position ladder of its 7.4.1, the
  distances of 7.3 and the corner height and 0.2 m from obstacles of 7.2 in a
  rectangular room; it also checks the measurement itself: the calibration
  deviation, the background time against the operator's tolerance and a
  background that varies, disturbed periods and the calculation against the
  instrument.
  Background noise is the one correction genuinely left to the caller of the
  insulation routines: their
  field levels must arrive already corrected, their 6 dB signal-to-background
  floor checked by the operator. Two helpers apply their own rule instead: the
  ISO 10140-4 laboratory one, warning when its floor is broken and capping the
  correction, and the Clause 9 field correction of ISO 16032 for service
  equipment, which holds its correction at 2.2 dB below a 4 dB margin and marks
  the result an upper limit. Two consequences worth naming: the background
  corrections are *different* rules, so neither helper is to be applied to
  the field data of an insulation index; and the intensity route takes both
  the pressure and the intensity level as inputs, with the scanning probe and
  its phase-mismatch calibration outside the library.

- **Not covered.** **Coverage inside the standards is partial in two places.** Of ISO 10848 only
  the Part 1 formulae are implemented generically, plus the Part 4 modal-overlap
  validity check, not the facility-specific setups of Parts 2, 3 and 4. Of the
  Spanish code, only the verification indices are implemented: the simplified
  option's solution tables of clause 3, the execution conditions of clause 5 and
  the maintenance conditions of clause 6 are out of scope, and the general
  option's calculation route is [Predicting Sound
  Insulation](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/).

- **Not covered.** **And there is no heavy-impact prediction at all.** A floor construction can
  be carried to a tapping-machine level by the models in [Insulation
  design](https://docs.jmrp.io/phonometry/buildings/design/); nothing does the same for the rubber
  ball, because the complexity of the input force and the use of a time-weighted
  maximum leave no simple counterpart. The heavy-impact page rates a
  measurement, and only a measurement.
