# Heavy and Soft Impact Sources (ISO 16283-2)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/insulation/heavy-impact-sources/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/insulation/heavy-impact-sources/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-30
Updated: 2026-11-16T21:36:14Z
Standards: ISO 16283-2:2020; ISO 10140-5:2021; JIS A 1418-2:2019; ISO 717-2:2020
Verified: 26 conformance checks (ISO 16283-2:2020; ISO 10140-5:2021; JIS A 1418-2:2019; ISO 717-2:2020) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Rubber ball and bang machine: force exposure level, the ISO 16283-2 and JIS A 1418-2 checks, Fast maximum level and the ISO 717-2 Annex D rating.

---

The ISO tapping machine is a *light* impact source. Its five 500 g hammers fall
40 mm and produce a hard, quasi-stationary excitation whose energy sits well
above 100 Hz, which is exactly where a bare concrete slab already performs
well. The impacts people actually complain about, a child jumping off a chair
or an adult walking barefoot on a timber floor, are slow, soft and
low-frequency, and the tapping machine says almost nothing about them. The
**standard heavy impact sources** were introduced to close that gap: a hollow
silicone **rubber ball** dropped from 1 m, and the **bang machine**, a car tyre
dropped from 85 cm. This guide covers their normative specification, the
laboratory verification of a source against it, the standardization of the
maximum level in the receiving room, and the A-weighted single number. The
tapping-machine chain lives in
[Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/) and
[Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/).

![Two panels: the octave-band impact force exposure levels of the rubber ball and the bang machine with their printed tolerance bands from 31.5 Hz to 500 Hz, and the ISO 717-2 Annex D rating of a field measurement showing the measured octave levels, their A-weighted contributions and the resulting single number](https://docs.jmrp.io/phonometry/media/heavy_impact_sources.svg)

*Left: the two source specifications are pure spectra of force, not geometry.
Right: the rating adds the A-weighted band contributions in energy, and the
A-weighting is 23 dB steeper at 63 Hz than at 500 Hz, so the quietest measured
band ends up deciding the number.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

from phonometry import building

fig, (ax_src, ax_rate) = plt.subplots(1, 2, figsize=(13.0, 5.6))

# Left: the printed nominal spectra inside their printed tolerance bands.
x = np.arange(5)
for source in ("rubber_ball", "bang_machine"):
    spec = building.heavy_impact_source_specification(source)
    limits = building.heavy_impact_source_limits(source)
    _f, lower, upper = limits.frequencies, limits.lower, limits.upper
    label = source.replace("_", " ")
    ax_src.fill_between(x, lower, upper, alpha=0.30, label=f"{label} tolerance")
    ax_src.plot(x, spec.force_exposure_level, "-o", label=f"{label} nominal")
ax_src.set_xticks(x, ["31.5", "63", "125", "250", "500"])
ax_src.set(xlabel="Frequency [Hz]",
           ylabel="Impact force exposure level LFE [dB re 1 N]")
ax_src.legend()

# Right: ISO 717-2:2020 Table D.4, measured levels against their A-weighted
# contributions, with the energy sum drawn across them.
res = building.a_weighted_max_impact_level([65.3, 64.5, 58.0, 55.8])
xr = np.arange(4)
ax_rate.bar(xr - 0.19, res.levels, width=0.36, label="Li,Fmax (measured)")
ax_rate.bar(xr + 0.19, res.corrected, width=0.36, label="Li,Fmax + A (Table D.3)")
ax_rate.axhline(res.rating, label=f"LiA,Fmax = {res.rating} dB")
ax_rate.set_xticks(xr, ["63", "125", "250", "500"])
ax_rate.set(xlabel="Frequency [Hz]",
            ylabel="Maximum impact sound pressure level [dB]")
ax_rate.text(0.02, 0.03, f"unrounded sum = {res.unrounded:.6f} dB",
             transform=ax_rate.transAxes, va="bottom", ha="left")
ax_rate.legend()
plt.show()
```

## Both sources are specified by the energy of their force pulse

A heavy source is not defined by its shape but by the **impact force exposure
level** it delivers into a rigid floor (ISO 16283-2:2020 Formula (A.1) =
JIS A 1418-2:2019 Formula (1)):

$$
L_\mathrm{FE} = 10\log_{10}\!\left[\frac{1}{T_\mathrm{ref}}
\int_{t_1}^{t_2}\frac{F^2(t)}{F_0^2}\,\mathrm{d}t\right]\ \text{dB re 1 N},
$$

with $F_0 = 1$ N (ISO 16283-2:2020 Annex A), $T_\mathrm{ref} = 1$ s and
$t_2 - t_1$ the duration of the impact. Watch the reference: EN 15657 refers
its blocked-force levels to $F_0 = 10^{-6}$ N, 120 dB away, so a force level
carried between this page and
[Structure-borne sound power of equipment](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/)
without conversion is wrong by exactly that. Both sources require a **single-peak** waveform of
$20 \pm 2$ ms (JIS A 1418-2:2019 A.2 b), where the two are called the
soft and the hard *impact characteristic*). The octave-band values are printed
identically in ISO 16283-2:2020 Table A.1, ISO 10140-5:2021 Table F.1 and
JIS A 1418-2:2019 Table A.2 for the ball; the bang machine appears only in
JIS A 1418-2:2019 Table A.1.

| Octave (Hz) | Rubber ball $L_\mathrm{FE}$ (dB re 1 N) | Bang machine $L_\mathrm{FE}$ (dB re 1 N) |
|---|---|---|
| 31.5 | 39.0 ± 1.0 | 47.0 ± 1.0 |
| 63 | 31.0 ± 1.5 | 40.0 ± 1.5 |
| 125 | 23.0 ± 1.5 | 22.0 ± 1.5 |
| 250 | 17.0 ± 2.0 | 11.5 ± 2.0 |
| 500 | 12.5 ± 2.0 | 5.5 ± 2.0 |

The bang machine puts 8 to 9 dB more energy into the two lowest octaves (8 dB
at 31.5 Hz, 9 dB at 63 Hz) and 7 dB
less into the top one, which is why the two sources are not interchangeable and
why a floor can pass one and fail the other.

```python
from phonometry import building
# `heavy_impact_source_specification` and `heavy_impact_source_limits` are the
# imports of the figure block above.

spec = building.heavy_impact_source_specification("rubber_ball")
print(spec.drop_height_m, spec.effective_mass)      # 1.0 m, 2.5 kg
print(spec.contact_time, spec.contact_time_tolerance)   # 0.02 s +/- 0.002 s

limits = building.heavy_impact_source_limits("bang_machine")
freqs, lower, upper = limits.frequencies, limits.lower, limits.upper
print(list(zip(freqs, lower, upper))[0])          # (31.5, 46.0, 48.0)

# A calibration run: five measured octave-band LFE against the printed table.
# Name the source: the check defaults to the rubber ball, and the bang machine
# limits fetched above would reject a conforming ball outright.
check = building.check_heavy_impact_source([39.4, 30.2, 23.6, 18.5, 12.9],
                                           source="rubber_ball")
print(check.passes, list(check.within_tolerance))
check.plot()   # measured LFE over the tolerance band (needs matplotlib)
```

`impact_force_exposure_level` evaluates Formula (A.1) directly from a sampled
force record, which is what the JIS A 1418-2 Annex C calibration procedure
measures with a force plate. The specification is stated **per octave band**,
and Annex C puts the filter between the transducer and the analyser, so the
record is band-filtered first and the formula is applied once per band: an
unfiltered pulse returns the broadband level, which is several decibels above
any single band value and must not be compared with the table above. A band
filter rings on after the 20 ms of the impact, the 31.5 Hz octave for some
tenths of a second, and its ring is part of the band's energy: the record runs
on in silence until the filters have died away. It is filtered forward, as a
filter between the transducer and the analyser filters the force as it comes: a
zero-phase filter (`zero_phase=True`) rings before the impact as well, so it
needs as much silence before it, and even then it reads these five bands 0.3 to
0.7 dB lower. The filter keeps the record's mean (`detrend=False`), which over
the impact and its ring is the pulse's own: taken off, it hands every band a
step at the start of the record, which moves the 500 Hz band by 0.2 dB here. A
measured record also carries the offset the transducer reads at rest, which is
no part of the pulse, so the mean of the samples before the impact is taken off
the record first: an offset of 50 N, a thirtieth of the peak, left in raises
the 500 Hz band by three quarters of a decibel. Cut at the end of the pulse,
the same five bands read -2.9, 7.7, 13.3, 5.7 and -3.2 dB, the 31.5 Hz band
41 dB low, and with the mean of so short a record taken off as well, as the
default `detrend=True` does, -6.7, 14.6, 23.0, 21.2 and 18.2 dB.

```python
import numpy as np
from phonometry import building, filters

fs = 48_000
t = np.arange(0.0, 1.0, 1.0 / fs)            # the impact and the filters' ring
# A single-peak half-sine pulse over the 20 ms contact time, then silence.
force = np.where(t < 0.020, 1500.0 * np.sin(np.pi * t / 0.020), 0.0)

# Broadband, i.e. the whole pulse energy: 10 lg(Fp^2 t / 2) = 43.5 dB.
# Not a band value, and not comparable with the table above.
print(round(building.impact_force_exposure_level(force, fs), 2))

# The five octave-band values the specification is actually written in.
bank = filters.OctaveFilterBank(fs, fraction=1, limits=[31.5, 500.0])
filtered = bank.filter(force, sigbands=True, calculate_level=False, detrend=False)
freqs, bands = filtered.frequencies, filtered.bands
lfe = [building.impact_force_exposure_level(b, fs) for b in bands]
print([round(v, 1) for v in lfe])   # [38.3, 30.8, 19.2, 8.9, -0.2]

# Those five go to the conformance check; this synthetic half-sine is not a
# rubber ball, so it does not conform:
#   check_heavy_impact_source(lfe).passes  ->  False
```

The construction examples the two standards give are informative, not
normative: a hollow silicone ball of 180 mm outer diameter with a 30 mm wall,
effective mass $(2.5 \pm 0.1)$ kg and coefficient of restitution
$0.8 \pm 0.1$, dropped from $(100 \pm 1)$ cm measured from the bottom of the
ball; and a car tyre inflated to $(2.4 \pm 0.2)\times 10^5$ Pa with an
effective mass of $(7.3 \pm 0.2)$ kg, dropped from 85 cm.

![Three impact sources over one floor slab: the ISO tapping machine with five 500 g hammers falling 40 mm, the 180 mm rubber ball with its 30 mm wall and the one metre drop dimensioned from the bottom of the ball, and the bang machine tyre dropped 85 cm, with the JIS Annex C calibration chain below showing the octave filter placed before the analyser](https://docs.jmrp.io/phonometry/media/diagram_heavy_impact_sources.svg)

### Which source

The choice is not free, and it is not a matter of taste. The **rubber ball** is
the source international standardisation adopted: ISO 16283-2:2020 Annex A and
ISO 10140-5:2021 Annex F both specify it, ISO 10052:2021 Clause 6.3.2 measures
with it, and it is light enough to use on a lightweight timber floor without
risk. The **bang machine** exists only in JIS A 1418-2:2019 and is used where
national practice calls for it, chiefly in Japan and Korea; its 7.3 kg tyre
dropped from 85 cm delivers 8 to 9 dB more force in the two lowest octaves,
which is precisely what makes it more searching on a heavy slab and what makes
it capable of damaging a light floor. Use the ball unless a national regulation
or a client specification names the bang machine, and never quote a result from
one against a limit written for the other.

## The receiving room: a maximum level cannot be corrected like an average

The rated quantity is a **maximum** of a Fast time-weighted level, not an
energy average, so the usual $10\log_{10}(T/T_0)$ standardization is wrong: a Fast
detector never integrates more than about 1.7 s of decay, so the correction has
to saturate. ISO 16283-2:2020 (definition 3.16, Formulae (4), (5) and (6))
therefore uses

$$
L'_{\mathrm{i,Fmax},V,T} = L_\mathrm{i,Fmax} + 10\log_{10}\frac{V}{V_0}
- 10\log_{10}\frac{g(C)}{g(C_0)},\qquad
C = \frac{T}{1.7275},\quad C_0 = \frac{T_0}{1.7275},
$$

with $T_0 = 0.5$ s, $V_0 = 50\ \text{m}^3$ for dwellings and, writing
Formula (4) compactly,

$$
g(C) = \frac{C^{1/(1-C)} - C^{-1/(1-1/C)}}{1 - 1/C}.
$$

$g$ is the peak of the Fast-weighted response to an exponentially decaying
burst. It has a removable singularity at $C = 1$ (i.e. $T = 1.7275$ s) where
its value is $1/e$. When $T = T_0$ the bracket collapses to 1 and the whole
correction reduces to the volume term, as it must.

The constant $1.7275$ s is **not** an integration limit: it is the Fast time
weighting written as a reverberation time. An exponential decay of $T$ seconds
has an energy time constant $\tau = T/(6\ln 10) = T/13.82$, so a room with
$T = 13.82 \times 0.125\ \text{s} = 1.7275\ \text{s}$ decays with
exactly the Fast detector's own $0.125$ s time constant, and $C = T/1.7275$
is the ratio of the two. Well below $C = 1$ the detector keeps up with the
decay and the correction behaves like the energy-average
$10\log_{10}(T/T_0)$; well above it the detector cannot follow, the peak it
reports stops growing with $T$, and the correction saturates. ISO 16283-2:2020
prints the constant without deriving it and refers to its Reference [1] for the
background.

![The term subtracted from a measured level against the receiving-room reverberation time from 0.2 to 5 seconds: the Fast-maximum term 10 lg of g(C) over g(C0) rising to about 5 dB, against the energy-average term 10 lg of T over T0 rising to 10 dB, the region where they differ by more than 1 dB shaded, with T0 = 0.5 s and T = 1.7275 s marked](https://docs.jmrp.io/phonometry/media/fast_reverberation_correction.svg)

*Both curves are the term the standardization *subtracts* from the measured
level, so they are directly comparable. At $T = T_0$ they vanish together, as
they must. Above it they separate: the energy-average correction keeps growing
without limit, because energy keeps accumulating, while the Fast term flattens,
because a 0.125 s detector stops resolving more decay. At $T = 5$ s the
energy-average rule would take off 10.0 dB and the Fast rule takes off 5.1 dB,
and that divergence is the whole reason ISO 16283-2 defines a separate
standardization for a maximum.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np

from phonometry import building

t = np.linspace(0.2, 5.0, 481)
fast = np.asarray(building.fast_reverberation_correction(t), dtype=float)
energy = 10 * np.log10(t / 0.5)
print(round(float(fast[-1]), 1), round(float(energy[-1]), 1))    # 5.1 10.0

fig, ax = plt.subplots()
ax.fill_between(t, fast, energy, where=np.abs(fast - energy) > 1.0,
                interpolate=True, alpha=0.25, label="more than 1 dB apart")
ax.plot(t, fast, label="Fast maximum: 10 lg[g(C)/g(C0)]")
ax.plot(t, energy, "--", label="energy average: 10 lg(T/T0)")
ax.set(xlabel="Receiving-room reverberation time T [s]",
       ylabel="Term subtracted from the measured level [dB]")
ax.legend()
plt.show()
```

```python
from phonometry import building
# `fast_reverberation_correction` is the import of the figure block above.

freqs = [63.0, 125.0, 250.0, 500.0]
li_fmax = [65.3, 64.5, 58.0, 55.8]           # energy-averaged over ball positions
t = [1.43, 3.70, 3.10, 2.38]                 # receiving-room reverberation time

res = building.standardized_max_impact_level(li_fmax, 41.4, t, frequencies=freqs)
print(res.volume_term)                        # -0.82 dB, which is 10 lg(41.4/50)
print(building.fast_reverberation_correction([0.5]))   # exactly 0 dB at T = T0
res.plot()   # measured and standardized spectra (needs matplotlib)

# One-third-octave measurements combine into octaves with Formula (20):
print(building.heavy_impact_octave_levels([60.0] * 6))   # [64.77 64.77]: 60 dB + 10 lg 3 per octave
```

## Measuring in the field (ISO 16283-2:2020, Clauses 6 to 9)

The functions above consume levels that have already been averaged over
positions. ISO 16283-2:2020 says how those positions are chosen, and the rubber
ball differs from the tapping machine at almost every step.

**Dropping the ball (Clause 7.2.3).** Vertical free fall from
$(100 \pm 1)$ cm, measured from the **bottom** of the ball to the surface of
the floor under test, not from the operator's hand and not from the centre of
the ball. **Four or more** positions on the floor or stairs under test; on a
lightweight joisted floor, one of them should be over a joist and one at the
centre of the floor, because those are the two extremes of the driving-point
mobility.

**Microphones (Clauses 7.3.1, 7.3.2, 7.6).** Fixed positions only: the
mechanized continuously moving microphone and the manual scan that the tapping
machine may use
([Taking the impact measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/#taking-the-impact-measurement-iso-16283-22020-clauses-4-7-9-and-10))
are **not** available for the ball, because a maximum level
cannot be spatially averaged along a path the way an energy average can. Fixed
positions may be on a tripod with nobody in the room, or with an operator
present whose trunk stays at least an arm's length from the microphone.
Distribute them through the permitted space, with no two in the same plane
relative to the boundaries and no regular grid, keeping at least 0.7 m between
positions, 0.5 m from the room boundaries and 1.0 m from the partition being
excited. The number of microphone positions equals the number of source
positions or an integer multiple of it: with four or five source positions, at
least two measurements at each from at least two different microphone
positions; with six or more, one measurement per source position at a different
microphone position each time.

**Averaging, in two stages (Clauses 7.8.3 and 7.3.4).** First energy-average
the maximum levels over the microphone positions belonging to one ball position
(Formula (14)); then energy-average those per-position results over the ball
positions (Formula (9)). Only then apply the standardization of Formulae (4),
(5) and (6). Averaging everything in one pass is not the same operation.

**Two things the tapping machine does that the ball does not.** The
low-frequency corner procedure of Clause 8 applies to the tapping machine only:
NOTE 2 to Clause 6 says plainly that no link has yet been shown between corner
and central-zone measurements for a *maximum* Fast-weighted level, so there is
nothing to combine. What does reach $L'_{\mathrm{i,Fmax},V,T}$ from that corner of
the standard is the 63 Hz octave reverberation time of Clause 10.4, and it
arrives here as one of the band reverberation times you supply. And the ball's level is **not corrected for background
noise** (Clause 9 NOTE), because it cannot be established whether a maximum
representing the background affected the maximum representing the impact.
Instead, keep the background low and say so.

The survey method reaches the same quantity by a shorter route:
[ISO 10052:2021 Clause 6.3.2](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-survey/#running-the-survey-clauses-5-and-6)
measures the Fast maximum in octave bands over about 10 s from at least two
fixed positions more than 0.7 m apart, one near the centre and one at a
different height, at least 0.5 m from the boundaries and 1.0 m from the impact.

## The single number is an A-weighted sum, not a shifted curve

ISO 717-2:2020 Annex D is normative and does not use a reference curve at all.
The rating is an energy sum of A-weighted band levels (Formula (D.1)):

$$
X_\mathrm{iA,Fmax} = 10\log_{10}\!\left(\sum_j 10^{(X_{\mathrm{i,Fmax},j} + A_j)/10}\right),
$$

over the one-third-octave bands 50 Hz to 630 Hz **or** the octave bands 63 Hz
to 500 Hz, with the Table D.3 corrections $A_j$, rounded half-up to an integer.
A one-third-octave measurement is rated in one-third octaves; the standard
warns explicitly against summing thirds into octaves first, because the two
routes do not give the same answer. The same formula rates all four quantities
of Tables D.1 and D.2: $L_\mathrm{iA,Fmax}$, $L_{\mathrm{iA,Fmax},V,T}$, $L'_\mathrm{iA,Fmax}$ and
$L'_{\mathrm{iA,Fmax},V,T}$.

The worked example of Table D.4 is reproduced exactly, including the
deliberately unrounded intermediate the standard prints:

```python
# `a_weighted_max_impact_level` is the import of the figure block above.

# ISO 717-2:2020 Table D.4: a field measurement in octave bands.
res = building.a_weighted_max_impact_level([65.3, 64.5, 58.0, 55.8])
print(list(res.corrected))   # 39.1, 48.3, 49.3, 52.6 dB
print(res.unrounded)         # 55.350667... dB
print(res.rating)            # 55 dB
res.plot()                   # band levels, A-weighted contributions, rating
```

Because the A-weighting is 23 dB steeper at 63 Hz than at 500 Hz, a heavy
source's rating is dominated by whichever band survives that slope. For the
Table D.4 spectrum the four A-weighted contributions are 39.1, 48.3, 49.3 and
52.6 dB, so the 500 Hz band carries the most weight even though 63 Hz is the
loudest measured band, 9.5 dB above it.

Read the 55 dB the way an impact quantity is read: **higher is worse**, as for
every impact level on this site. It is a maximum, not an average, so it is not
comparable with an $L'_{\mathrm{n}T,\mathrm{w}}$ or an $L'_\mathrm{n,w}$ from the tapping machine, and
ISO sets no limit on it: heavy-impact criteria are national. The most
developed of them is Korea's, where floor impact sound in apartment housing has
been regulated since 2004 and the rules were rewritten in August 2022: the
heavyweight source became the rubber ball, the evaluation index became exactly
the $L'_\mathrm{iA,Fmax}$ of this section (through KS F ISO 10140-5 and
KS F ISO 717-2), and the mandatory performance standard was set at **49 dB**,
tightened from the 50 dB of the previous bang-machine scheme. Above that
threshold sit four grades at 4 dB intervals, grade 1 being the best:
$L \le 37$, $37 < L \le 41$, $41 < L \le 45$ and $45 < L \le 49$ dB. Against
that scale, the 55 dB of the worked example is a floor that fails the standard
outright. Because the number is set by the low-frequency bands, what moves it
is mass and structural decoupling (a thicker slab, a floating floor on a soft
resilient layer, a decoupled ceiling) and *not* a soft covering, which acts
where the A-weighting has already discarded the energy.

## What this guide covers

- **Covered.** The impact force exposure level of ISO 16283-2:2020 Formula (A.1) from a
  sampled force record, via `building.impact_force_exposure_level`; the printed
  octave-band specifications of ISO 16283-2:2020 Table A.1 / ISO 10140-5:2021
  Table F.1 (rubber ball) and JIS A 1418-2:2019 Tables A.1 and A.2 (both
  characteristics) with their tolerances, via
  `building.heavy_impact_source_specification`,
  `building.heavy_impact_source_limits` and
  `building.check_heavy_impact_source`; the standardized maximum impact sound
  pressure level of Formulae (4), (5) and (6) and the octave synthesis of
  Formula (20), via `building.standardized_max_impact_level`,
  `building.fast_reverberation_correction` and
  `building.heavy_impact_octave_levels`; and the normative A-weighted rating of
  ISO 717-2:2020 Annex D with the Table D.3 corrections, via
  `building.a_weighted_max_impact_level`.

- **Not covered.** The field procedure documented above is not automated: the functions consume
  levels that were already energy-averaged over the microphone positions of one
  ball position and then over the ball positions, and nothing checks the drop
  height, the four-or-more source positions, the microphone separations or the
  two-stage averaging. Nor is the horizontal-arrangement guidance of ISO
  16283-2:2020 Annex E, which is informative. There is no prediction model that
  takes a floor construction to a heavy-impact level; Hopkins states plainly
  that the complexity of the input force and the use of a time-weighted maximum
  leave no simple counterpart to the tapping-machine prediction. No accredited
  worked example exists anywhere that carries a real floor from measured
  $L_\mathrm{i,Fmax}$ through to $L'_{\mathrm{iA,Fmax},V,T}$, so the standardization chain is
  anchored on its own $T = T_0$ identity and on a published 25-band reproduction
  of Formula (4).

## See also

- [Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/): the
  tapping-machine chain of the same standard.
- [Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/): the ISO 10140
  laboratory suite the heavy sources extend.
- [Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/): the reference-curve
  engine that rates the tapping-machine quantities.
- [Floor-Covering Impact Improvement (ISO 16251-1)](https://docs.jmrp.io/phonometry/buildings/design/impact-improvement/):
  the improvement a soft covering gives against the light source.
- API reference: [`building.measurement.heavy_impact`](https://docs.jmrp.io/phonometry/reference/api/building/heavy-impact/).
- Theory: [Sound insulation and absorption, measured](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/#sound-insulation-and-absorption-measured-iso-16283-iso-10140-iso-717-iso-354): the impact-level normalisations of ISO 10140 and ISO 717-2 that the rubber ball and bang machine feed.

## References

- **Hopkins, C. (2007).** *Sound insulation*. Butterworth-Heinemann. https://doi.org/10.4324/9780080550473
  Section 3.6.4 describes the heavy impact sources and explains why no simple prediction counterpart exists. ISBN 978-0-7506-6526-1.
- **International Organization for Standardization. (2010).** [*Acoustics — Laboratory measurement of sound insulation of building elements — Part 3: Measurement of impact sound insulation*](https://www.iso.org/standard/42089.html) (ISO 10140-3:2010).
  Annex A (informative), the laboratory measurement with heavy and soft impact sources.
- **International Organization for Standardization. (2020).** [*Acoustics — Field measurement of sound insulation in buildings and of building elements — Part 2: Impact sound insulation*](https://www.iso.org/standard/77436.html) (ISO 16283-2:2020).
  Annex A.2 and Table A.1 specify the rubber ball; definition 3.16 and Formulae (4), (5) and (6) give the Fast-weighted standardization, Formula (20) the octave synthesis.
- **International Organization for Standardization. (2020).** [*Acoustics — Rating of sound insulation in buildings and of building elements — Part 2: Impact sound insulation*](https://www.iso.org/standard/69867.html) (ISO 717-2:2020).
  Annex D (normative) gives the A-weighted maximum impact sound pressure level, its Table D.3 corrections and the Table D.4 worked example reproduced on this page.
- **International Organization for Standardization. (2021).** [*Acoustics — Laboratory measurement of sound insulation of building elements — Part 5: Requirements for test facilities and equipment*](https://www.iso.org/standard/79482.html) (ISO 10140-5:2021).
  Annex F (normative) prints the same rubber-ball spectrum as Table F.1 and specifies the modified tapping machine.
- **Japanese Standards Association. (2019).** [*Acoustics — Measurement of floor impact sound insulation of buildings — Part 2: Method using standard heavy impact sources*](https://www.jisc.go.jp/) (JIS A 1418-2:2019).
  The only primary source for the bang machine: Annex A Tables A.1 and A.2 with tolerances, the 20 ms single-peak requirement, and the Annex B construction examples.
- **Kim, K. W., Park, S. H., Shin, H. K., & Kim, K. C. (2023).** Changes of floor impact sound regulations and future improvement directions in Korea. *Proceedings of Forum Acusticum 2023 (10th Convention of the European Acoustics Association)*. https://doi.org/10.61782/fa.2023.0364
  Table 1 records the August 2022 revision: the heavyweight source became the rubber ball, the index L'iA,Fmax through KS F ISO 10140-5 and KS F ISO 717-2, the mandatory standard 49 dB (from 50 dB) and the four grades at 4 dB intervals. The only published regulatory scale for the quantity this page computes.