# Rooms and buildings

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-16
Updated: 2026-10-06T02:25:32Z
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Room acoustics measured and predicted (ISO 3382, EN 12354-6), and sound insulation measured in the field and the laboratory and predicted by EN 12354.

---

This section covers sound in the built environment, and it splits along a
natural line: what happens **inside** one room, and what passes **between**
rooms. Inside a room, the governing quantity is absorption: it sets the
reverberation time and the clarity that room acoustics measures (ISO 3382)
and predicts (Sabine and its refinements, EN 12354-6), while the background
noise the room settles into is rated against criterion curves
(ANSI/ASA S12.2). Between rooms, the governing quantity is insulation: how much
airborne and impact sound a partition and its flanking paths transmit, measured
in the field (ISO 16283) or the laboratory (ISO 10140) and predicted from
element data (EN 12354).

Both halves consume coefficients measured elsewhere: the
[Materials and surfaces](https://docs.jmrp.io/phonometry/materials/)
section characterises the absorption, impedance and scattering data that the
room and insulation predictions here rely on.

Start with
[Measuring the Room Impulse Response](https://docs.jmrp.io/phonometry/buildings/rooms/room-impulse-response/)
and [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the impulse response
the first acquires and the parameters the second derives are the vocabulary
the rest of the section speaks. If your interest is insulation, read
[Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/)
next, and note that impact sources other than the tapping machine have their own
page, since ISO 16283-2 is the clause a field engineer usually arrives with; if
it is design-stage prediction, go to
[Reverberation-time prediction (Sabine, Eyring, Arau)](https://docs.jmrp.io/phonometry/buildings/rooms/reverberation-prediction/)
and [Predicting Sound Insulation (EN 12354)](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/).

## [Room acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/)

The sound field inside a single room: measured from an impulse response, rated
against criterion curves, and predicted from volume and absorption.

- [Measuring the Room Impulse Response](https://docs.jmrp.io/phonometry/buildings/rooms/room-impulse-response/):
  the ISO 18233 deterministic acquisition, sweep deconvolution and MLS.
- [Room Acoustics](https://docs.jmrp.io/phonometry/buildings/rooms/room-acoustics/): the ISO 3382-1/2 room
  parameters derived from that impulse response.
- [Open-Plan Office Acoustics (ISO 3382-3)](https://docs.jmrp.io/phonometry/buildings/rooms/open-plan-acoustics/):
  the speech-privacy quantities of an open-plan floor.
- [Image sources and the steady-state room field](https://docs.jmrp.io/phonometry/buildings/rooms/room-image-sources/):
  the deterministic image-source impulse response and the statistical
  steady-state level.
- [Room-noise criteria (NC / RC Mark II)](https://docs.jmrp.io/phonometry/buildings/rooms/room-noise/): the
  ANSI/ASA S12.2-2019 room-noise ratings with their spectral tags.
- [Reverberation-time prediction (Sabine, Eyring, Arau)](https://docs.jmrp.io/phonometry/buildings/rooms/reverberation-prediction/):
  Sabine, Eyring, Millington-Sette, Fitzroy and Arau-Puchades models with the
  air-absorption term.
- [Sound absorption in enclosed spaces (EN 12354-6)](https://docs.jmrp.io/phonometry/buildings/rooms/enclosed-space-absorption/):
  the normative prediction of a room's total equivalent absorption area and
  reverberation time.

## [Sound insulation](https://docs.jmrp.io/phonometry/buildings/insulation/)

Airborne and impact insulation: measured in the building, characterised in the
laboratory, and predicted from element data.

- [Field Insulation Measurement (ISO 16283)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-field/):
  ISO 16283-1/2 field measurement, the Clause 14 report and the ISO 12999-1
  uncertainty that qualifies it.
- [Small Rooms: the ISO 16283 Low-Frequency Procedure](https://docs.jmrp.io/phonometry/buildings/insulation/low-frequency-procedure/):
  the corner measurement that becomes mandatory below 25 m³, and the 63 Hz
  octave reverberation time that comes with it.
- [Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/):
  the ISO 10140 laboratory characterisation of an element.
- [Linings, Floor Coverings, Joints and Rain (ISO 10140-1)](https://docs.jmrp.io/phonometry/buildings/insulation/lab-application-rules/):
  what a lining or a floor covering adds, rated on the ISO 717 reference
  curves, what a sealed joint lets through per metre, and the sound of rain on
  a roof.
- [Sound Insulation by Intensity (ISO 15186)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-intensity/):
  the direct-power route to the same indices when flanking is high.
- [Sound Insulation Survey Method (ISO 10052)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-survey/):
  the octave-band control method and its reverberation index.
- [Service-Equipment and Activity Noise (ISO 16032)](https://docs.jmrp.io/phonometry/buildings/insulation/service-equipment-noise/):
  the engineering method for equipment and activity noise in a room, from the
  ISO/DIS 16032:2023 draft.
- [Heavy and Soft Impact Sources (ISO 16283-2)](https://docs.jmrp.io/phonometry/buildings/insulation/heavy-impact-sources/):
  the rubber ball and the bang machine, the impact force exposure level that
  specifies them and the ISO 717-2 Annex D single number.
- [Laboratory Flanking Transmission (ISO 10848)](https://docs.jmrp.io/phonometry/buildings/insulation/flanking-lab/):
  the measured junction vibration reduction index, the flanking descriptors,
  and the suspended-ceiling plenum path with its ceiling attenuation class.
- [Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/): the
  reference-curve engines behind Rw, DnT,w, Ln,w and their adaptation terms.
- [Façade Sound Insulation](https://docs.jmrp.io/phonometry/buildings/insulation/facade-insulation/): the
  building envelope measured (ISO 16283-3) and predicted (EN 12354-3/4).
- [Spanish Building Code (CTE DB-HR)](https://docs.jmrp.io/phonometry/buildings/insulation/spanish-building-code/):
  the DB-HR global indices, the clause 2 requirements and the window-size
  correction.

## [Insulation design](https://docs.jmrp.io/phonometry/buildings/design/)

The same quantities before the building exists: predicted from element data,
and from the physics of the element itself.

- [Predicting Sound Insulation (EN 12354)](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/):
  airborne and impact flanking transmission between rooms (EN 12354-1/2).
- [Detailed Per-Band Prediction (ISO 12354)](https://docs.jmrp.io/phonometry/buildings/design/detailed-prediction/):
  the same prediction band by band, with the per-path contributions behind
  R'w and L'n,w.
- [Predicting Panel Sound Insulation](https://docs.jmrp.io/phonometry/buildings/design/panel-sound-insulation/):
  the mass law, coincidence dip, double walls and apertures.
- [Floor-Covering Impact Improvement (ISO 16251-1)](https://docs.jmrp.io/phonometry/buildings/design/impact-improvement/):
  the weighted improvement of a soft covering on a small heavyweight mock-up.
- [Predicting Resilient-Layer Performance](https://docs.jmrp.io/phonometry/buildings/design/resilient-layers/):
  the prediction side of coverings, floating floors and wall linings.
- [Structure-borne sound power of equipment (EN 15657)](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/):
  the reception-plate method and the plate-independent source quantities.
- [Installed structure-borne sound (EN 12354-5)](https://docs.jmrp.io/phonometry/buildings/design/installed-structure-borne/):
  the receiving-room sound pressure level predicted from source and receiver
  mobilities.
- [Dynamic stiffness of resilient materials (EN 29052-1)](https://docs.jmrp.io/phonometry/materials/resilient/dynamic-stiffness/):
  the load-plate resonance measurement behind every floating-floor prediction.

## What this section does not cover

- **Not covered.** **The library starts after the microphone and stops before the geometry.** On
  the measurement side, position averaging happens once positions are supplied
  (the insulation functions energy-average per-position spectra for you), but
  nothing verifies how the measurement was made: the position counts and
  placements, the corner positions the ISO 16283 low-frequency procedure is fed
  from and the test-facility qualifications of ISO 16283, ISO 10140 and ISO 3382
  are the operator's job. The exception is the ISO 16032 engineering method for
  service-equipment noise,
  which checks its own position ladder, the distances of its 7.3 and the height
  of its corner position and its 0.2 m from obstacles (7.2), and the numbers its
  draft sets for the measurement itself: the calibration deviation, the
  background measured over approximately 30 s against the tolerance the operator
  gives, a background that varies, disturbed periods and the calculation against
  the instrument. Elsewhere, measuring the background noise is the operator's
  job too, and two corrections are implemented: the ISO 10140-4
  laboratory one, warning when its 6 dB floor is broken, and the Clause 9 field
  correction of ISO 16032 for service equipment, held at 2.2 dB below a 4 dB
  margin. The field levels of an insulation index must arrive already
  corrected. On the prediction side, the element ratings, the
  junction indices and the covering improvements are inputs you supply from
  measurement or from a standard's own annex; none is derived from a drawing.

- **Not covered.** **Nothing here is a wave solver or a room model.** There is no geometry
  importer, no material database, no ray tracer and no auralisation: the room
  pages take dimensions, absorption coefficients and impulse responses and give
  back parameters, and the image-source model is specular only. An actual
  low-frequency field in a real shape is [wave
  simulation](https://docs.jmrp.io/phonometry/simulation/).

- **Not covered.** **And a prediction is not a verdict.** The single-number ratings and the
  national indices are computed here, but the limit values they are judged
  against are national (the Spanish code is implemented as a worked example of
  one such framework, not as the rule everywhere), and the requirement always
  comes from your regulation.

## Before and after these pages

Every quantity on these pages starts from band levels or from a filtered
impulse response, so the calibration, weighting and fractional-octave
filtering behind them are in [Signal analysis](https://docs.jmrp.io/phonometry/signals/), and
[Build a sound level meter](https://docs.jmrp.io/phonometry/signals/sound-level-meter/) runs that
chain end to end on one runnable page. The derivations sit in [Rooms and
buildings theory](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/), from the Schroeder integration
to the EN 12354 path sums.

If you arrived here from a search and want the shape of the whole library,
[What do you need to measure?](https://docs.jmrp.io/phonometry/start/tasks/) indexes it by the job
and [All guides](https://docs.jmrp.io/phonometry/start/guides/) lists every page with a line on
each.