# Installed structure-borne sound (EN 12354-5)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/design/installed-structure-borne/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/design/installed-structure-borne/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-11
Updated: 2026-11-16T21:36:14Z
Standards: EN 12354-5:2009
Verified: 4 conformance checks (EN 12354-5:2009) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Receiving-room level from structure-borne service-equipment sound (EN 12354-5:2009): coupling term D_C, installed power, per-path and total level.

---

**EN 12354-5:2009** predicts the sound pressure level in a receiving room caused
by building service equipment (pumps, fans, lifts, water installations) that
injects **structure-borne sound** into the building. It closes the
structural-vibroacoustics chain: the source is described by its characteristic
structure-borne sound power level $L_\mathrm{Ws,c}$, derived from the EN 15657
reception-plate measurement through the Formula (15)/(17) conversion and a
mobility correction (**not** the raw plate-injected level;
see [EN 15657](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/)); the source and
receiver point mobilities set how much power is actually coupled into the
structure, and the building transmission carries it to the receiving room. The
Annex I mobility correction `installed_power_from_reception_plate` refers the
characteristic reception-plate level $L_\mathrm{Ws,n}$ to the actual receiver,
$L_\mathrm{Ws,inst} = L_\mathrm{Ws,n} + 10\log_{10}(Y_{\infty,i} / Y_{\infty,\mathrm{rec}})$
with $Y_{\infty,\mathrm{rec}} = 5\cdot 10^{-6}\ \text{m/(N·s)}$;
with the source mobility instead it yields $L_\mathrm{Ws,c}$ (Annex I.3, Table I.8).

![The EN 12354-5 cascade per octave band: characteristic power, installed power after the coupling term, per-path sound pressure levels and their energetic total](https://docs.jmrp.io/phonometry/media/installed_structure_borne.svg)

*The whole chain on one axis, per octave band. The coupling term is not a fixed
toll: it takes 6.6 dB out of the characteristic power at 63 Hz and 20.8 dB at
4 kHz, so the installed spectrum tilts down before any path is applied. Each
path then subtracts its own $D_\mathrm{sa}$, flanking index and area term, and here the
smaller flanking wall beats the floor by 1.3 to 2.3 dB. The receiving-room level
is the **energetic sum** of the paths, 2.0 to 2.4 dB above the stronger of the
two: fixing only the worst path would buy about 2 dB, not the difference.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import building

# EN 15657 characteristic source power and illustrative point mobilities.
bands = np.array([63.0, 125.0, 250.0, 500.0, 1000.0, 2000.0, 4000.0])
lws_c = np.array([78.0, 82.0, 84.0, 81.0, 77.0, 72.0, 66.0])
ys = (2e-4 + 1e-4j) * (bands / 250.0)        # source mobility
yi = (3e-5 + 1e-5j) * np.ones_like(bands)    # receiver mobility
dc = np.array([float(building.coupling_term(a, b)) for a, b in zip(ys, yi)])

# Two transmission paths: the excited floor and a flanking wall. Dsa is
# negative and falls with frequency (Annex F.2), and enters with a minus sign.
paths = [
    {"adjustment_term": np.array([-14.0, -17.0, -20.0, -25.0, -30.0, -35.0, -40.0]),
     "element_area": 12.0,
     "flanking_reduction_index": np.linspace(44.0, 62.0, 7)},
    {"adjustment_term": np.array([-16.0, -19.0, -23.0, -28.0, -33.0, -38.0, -43.0]),
     "element_area": 9.0,
     "flanking_reduction_index": np.linspace(46.0, 64.0, 7)},
]
res = building.installed_source_prediction(lws_c, dc, paths, frequencies=bands)
res.plot()   # characteristic and installed power, per-path levels and the total
plt.show()
```

## 1. Coupling and installed power

Only part of the characteristic power is injected into the supporting element;
the loss is the **coupling term** $D_\mathrm{C}$, set for a point excitation by the
source mobility $Y_\mathrm{s}$ and the receiver mobility $Y_i$ (Formula 19b):

$$
D_{\mathrm{C},i} = 10\log_{10}\frac{|Y_\mathrm{s} + Y_i|^2}{|Y_\mathrm{s}|\,\mathrm{Re}\{Y_i\}},
$$

which reduces to $10\log_{10}(|Y_\mathrm{s}|/\mathrm{Re}\{Y_i\})$ for a **force source** (high source
mobility, Formula 19c) and to $-10\log_{10}(|Y_\mathrm{s}|\,\mathrm{Re}\{Z_i\})$ for a **velocity source**
(low source mobility, Formula 19d); an elastic support adds its transfer
mobility $Y_k$ inside the modulus (Formula 19e). The **installed** power level is
then (Formula 18b) $L_\mathrm{Ws,inst} = L_\mathrm{Ws,c} - D_\mathrm{C}$.

The two limits are usable once the mobilities differ by about an order of
magnitude: at $|Y_\mathrm{s}|/|Y_i| = 10$ the force-source form is 0.8 dB below the exact
Formula 19b value and at 100 it is 0.1 dB below, while between those extremes the
phase relationship decides the answer and Formula 19b must be evaluated with
complex mobilities rather than magnitudes. Read the two idealisations
physically: a **force source** imposes its force whatever the receiver does, so a
stiffer receiver simply vibrates less and accepts less power, and $D_\mathrm{C}$ stops
depending on the receiver's magnitude at all; a **velocity source** imposes its
motion, so a stiffer receiver now takes *more* power out of it and the dependence
inverts. A pump on a concrete slab is the textbook force source; a heavy machine
bolted rigidly to a light timber floor is the case where the intuition flips, and
the mid range, a mounted machine near its support resonance, is where $D_\mathrm{C}$ is
smallest and can even go negative, because the $|Y_\mathrm{s} + Y_i|^2$ numerator collapses
when the two mobilities are comparable and in antiphase. The exact curve bottoms
out at matched mobilities, which is best power transfer and therefore worst
isolation.

This is the same $L_\mathrm{Ws,inst}$ as the Annex I mobility correction of
the introduction, reached by a different route: use Formula (18b) when $D_\mathrm{C}$ is
known from the two mobilities, and the direct correction
$L_\mathrm{Ws,n} + 10\log_{10}(Y_{\infty,i}/Y_{\infty,\mathrm{rec}})$ when it is not.
On the Annex I.3 cistern both give 68.2 dB at 63 Hz, from
$L_\mathrm{Ws,c} = 84.4$ dB and $D_\mathrm{C} = 16.2$ dB. Note which quantity you are handed:
$L_\mathrm{Ws,c}$ is the input this page takes, and it is *not* the 68.2 dB the
[EN 15657 page](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/) prints as
its installed level because feeding that in subtracts $D_\mathrm{C}$ twice.

The physics behind $D_\mathrm{C}$ is the classical power input of a point-excited
plate: only the real part of the receiver's driving-point mobility absorbs
power, and the mismatch between $Y_\mathrm{s}$ and $Y_i$ decides how much of the
source's capability ever enters the structure (Hopkins 2007, Section 2.8).
The mobilities themselves come from the
[mechanical-mobility chain](https://docs.jmrp.io/phonometry/vibration/structural/mechanical-mobility/): measured
per ISO 7626, or from the infinite-plate closed forms of
[panel theory](https://docs.jmrp.io/phonometry/buildings/design/panel-sound-insulation/) when no measurement
exists. A pump on a concrete slab is the textbook force source: its casing
mobility is orders of magnitude above the slab's, so $D_\mathrm{C}$ collapses to
Formula 19c and the injected power no longer depends on the receiver at all.

```python
from phonometry import building

# A near-force source (Y_s >> Y_i) on a concrete floor:
dc = building.coupling_term(2e-4 + 1e-4j, 3e-5 + 1e-5j)
print(round(float(dc), 2))                                          # 9.86 dB
print(round(float(building.installed_structure_borne_power_level(82.0, dc)), 1))  # 72.1 dB

# The two limits, for comparison: |Y_s|/|Y_i| is only 7 here, so the
# force-source form is already 1.1 dB away from the exact Formula 19b value.
print(round(float(building.coupling_term_force_source(2e-4 + 1e-4j, 3e-5 + 1e-5j)), 2))      # 8.72
print(round(float(building.coupling_term_velocity_source(2e-4 + 1e-4j, 1 / (3e-5 + 1e-5j))), 2))  # -8.27
```

![Coupling term against the source-to-receiver mobility ratio: the exact Formula 19b curve with its force-source and velocity-source asymptotes, the minimum at matched mobilities, the pump example marked, and two elastic-support curves showing the decibels a mount buys](https://docs.jmrp.io/phonometry/media/coupling_term_regimes.svg)

*The whole of Formula 19b on one axis. Far to the right the source is a force
source and $D_\mathrm{C}$ follows $10\lg(|Y_\mathrm{s}|/\mathrm{Re}\{Y_i\})$; far to the left it is
a velocity source and follows $-10\lg(|Y_\mathrm{s}|\,\mathrm{Re}\{Z_i\})$; the exact curve
leaves both asymptotes within about a decade of matched mobilities, where it
reaches its minimum of 6.2 dB (maximum power transfer, minimum isolation). The
pump of the snippet sits at a ratio of only 7.1, which is why its exact 9.9 dB is
1.1 dB above the force-source limit. Adding an elastic support (Formula 19e)
shifts the whole curve up: a transfer mobility of $10^{-4}$ m/(N·s) buys 2.7 dB
at the pump's ratio and one of $10^{-3}$ buys 13.7 dB, which is the isolation
budget of a mount read straight off the coupling term.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
# `building` is the module imported by the snippet above.

yi = 3e-5 + 1e-5j                     # receiver mobility, fixed
ratio = np.logspace(-3.0, 3.0, 400)   # |Y_s| / |Y_i|
ys = abs(yi) * ratio * (2 + 1j) / abs(2 + 1j)

exact = np.array([float(building.coupling_term(a, yi)) for a in ys])
force = np.array([float(building.coupling_term_force_source(a, yi)) for a in ys])
velocity = np.array([float(building.coupling_term_velocity_source(a, 1 / yi))
                     for a in ys])

fig, ax = plt.subplots()
ax.semilogx(ratio, exact, label="Formula 19b (exact)")
ax.semilogx(ratio, force, "--", label="force source (19c)")
ax.semilogx(ratio, velocity, ":", label="velocity source (19d)")
for yk in (1e-4, 1e-3):               # elastic support, Formula 19e
    ax.semilogx(ratio, [float(building.coupling_term(a, yi, transfer_mobility=yk))
                        for a in ys], label=f"with $Y_k$ = {yk:g} m/(N·s)")
ax.plot(7.07, 9.86, "o")              # the pump of the snippet
ax.set(xlabel=r"Mobility ratio $|Y_\mathrm{s}| / |Y_i|$",
       ylabel=r"Coupling term $D_\mathrm{C}$ [dB]")
ax.legend()
plt.show()
```

### Table D.1: $Y_\mathrm{s}$ from the machine's own parts

Nothing measures the source mobility of a boiler. Clause D.1.3 builds it
instead out of the parts that carry the vibration to the feet, and Table D.1
gives the six closed forms it uses. `typical_element_mobility` is that table:

| Row | Describing quantities | $\lvert Y\rvert$ in m/N.s |
| --- | --- | --- |
| `"mass"` | $M$ [kg] | $[2\pi f M]^{-1}$ |
| `"bar_end"` | $\rho$ [kg/m3], $c_\mathrm{L}$ [m/s], $S$ [m²] | $[\rho c_\mathrm{L} S]^{-1}$ |
| `"beam"` | $\rho$, $c_\mathrm{L}$, $t$ [m], $w$ [m] | $[7.6\,\rho t w\sqrt{c_\mathrm{L} t f}]^{-1}$ |
| `"plate"` | $\rho$, $c_\mathrm{L}$, $t$ [m] | $[2.3\,c_\mathrm{L}\rho t^2]^{-1}$ |
| `"pipe"` | $\rho$, $c_\mathrm{L}$, $t$ [m], $r$ [m] | $[63\,\rho t r\sqrt{c_\mathrm{L} r f}]^{-1}$ |
| `"mass_spring"` | $M$ [kg], $s$ [N/m], $\eta$ [-] | $\left[\left(\frac{2\pi f\eta}{s(1+\eta^2)}\right)^2 + \left(\frac{2\pi f}{s(1+\eta^2)} - \frac{1}{2\pi f M}\right)^2\right]^{1/2}$ |

Frequency is not in the "describing quantities" column, because it is the band
frequency of the prediction rather than a property of the element, but it is
in four of the six expressions, so those four rows take `frequency` and the
other two refuse it. `TABLE_D1_QUANTITIES` holds the column, row by row, and a
row accepts only the quantities it lists there. Pick the row by what actually carries the vibration: a
small compact machine is its total mass, a machine on non-rigid feet is the
mass-spring row, and the pipework leaving a pump is the pipe row. Note that
`"plate"` is Formula (F.4) again, written in $\rho$, $c_\mathrm{L}$ and $t$ instead of
mass and bending stiffness (the same number as `vibration.infinite_plate_mobility`).

```python
from phonometry import building

# A 120 kg pump on four rubber mounts, 1.0e6 N/m each, loss factor 0.1.
y_feet = building.typical_element_mobility(
    "mass_spring", frequency=125.0, mass=120.0, stiffness=4.0e6, loss_factor=0.1
)
print(f"{float(y_feet):.3g}")                       # 0.000185 m/(N.s)

# Well above the 29 Hz mount resonance the feet dominate: the casing on its
# own is an order of magnitude stiffer, so the mounts are what sets Y_s.
y_casing = building.typical_element_mobility("mass", frequency=125.0, mass=120.0)
print(f"{float(y_casing):.3g}")                     # 1.06e-05 m/(N.s)

dc = building.coupling_term(y_feet, 3e-5 + 1e-5j)   # onto a concrete floor
print(round(float(dc), 1))                          # 9.2 dB
```

The mass-spring row is the only one with a turning point. It is the series sum
of a spring mobility and a mass mobility, so its second bracket holds the two
reactances and they cancel at $f_0 = (2\pi)^{-1}\sqrt{s(1+\eta^2)/M}$, leaving
$\lvert Y_\mathrm{s}\rvert$ at its damping-limited *minimum*, which is the frequency
at which the mount injects the **most** power, because a small source mobility
is a small $D_\mathrm{C}$. That is the mounting resonance, and $\eta$ is the only thing
setting how bad it gets. A row called with a quantity it does not
describe, or with a `frequency` its expression does not contain, raises rather
than quietly using a default.

### Where the machine is fixed is part of $Y_i$

The receiver mobility is not a material constant of the element; it is a
property of the *point* the machine is bolted to. EN 12354-5 Annex F.3 gives
three routes to it, in decreasing order of authority.

**Measured.** Point mobilities at the actual contact points, normal to the
surface, per ISO 7626-1 with single-point translational excitation per
ISO 7626-2 (impact excitation per ISO 7626-5 is allowed), narrowband and then
reduced to one-third octaves. The receiver must **not** be dynamically loaded
while its mobility is measured: an important asymmetry with the source, which
is isolated or freely suspended instead.

**Calculated, mid-panel.** For excitation in the centre area of a large
homogeneous element, Formula (F.4) gives the real, frequency-independent
infinite-plate value $Y_{i,\infty} = 1/(8\sqrt{m'B'}) = (2.3\,c_\mathrm{L}\rho t^2)^{-1}$,
which is `vibration.infinite_plate_mobility(B, m)` in the library.
It is valid only *above* the element's lowest resonance
$f_{11} = (c_0^2/4f_\mathrm{c})(1/l_1^2 + 1/l_2^2)$ (Formula F.5); below $f_{11}$ the
mobility turns complex and is set by the stiffness of the element's supports, not
by its own mass and bending stiffness. For the 5.00 m × 4.00 m, 220 mm concrete
floor of the worked building $f_{11}$ is 39 Hz, comfortably below the range, but
for a 1.20 m × 0.80 m concrete plinth of the same thickness it is 781 Hz, right in
the middle of it, so on small stiff elements the closed form is the wrong tool.
Elements with beams split again (Formula F.3.2): below $f_{11}$ use the effective
bending stiffness $\sqrt{B'_xB'_y}$; above it, excitation between the beams uses
the plate field and excitation on a beam uses the beam's own mobility.

**Corrected for the fixing position.** Near a rigid edge the real part collapses
as $\mathrm{Re}\{Y_i\} = \mathrm{Re}\{Y_{i,\infty}\}\,[1 - J_0(2k_\mathrm{B}a)]$ (Formula
F.6a, with a corner form F.6b), $a$ being the distance to the edge. This makes
the fixing distance a design variable rather than a detail: on that same concrete
floor at 63 Hz, bolting the machine 0.20 m from a wall leaves 6.5 % of the
mid-panel real mobility (11.9 dB less injected power) and 0.50 m leaves 37 %,
worth 4.3 dB. Move a pump towards a junction and it feeds the building less.

```python
import numpy as np
from scipy.special import j0

rho, c_l, t = 2200.0, 3800.0, 0.220         # concrete, 220 mm
m, b = rho * t, c_l**2 * rho * t**3 / 12.0  # mass per area, bending stiffness
y_inf = 1.0 / (8.0 * np.sqrt(m * b))        # Formula (F.4), mid-panel
print(f"{y_inf:.3g}")                       # 1.07e-06 m/(N.s)

f_c = 343.0**2 / (1.8 * c_l * t)            # critical frequency
f_11 = 343.0**2 / (4 * f_c) * (1 / 5.0**2 + 1 / 4.0**2)
print(round(f_c, 1), round(f_11, 1))        # 78.2 Hz, 38.6 Hz -> F.4 valid here

f, a = 63.0, 0.20                           # 0.20 m from a rigid edge
k_b = np.sqrt(2 * np.pi * f) * (m / b) ** 0.25
print(round(float(1 - j0(2 * k_b * a)), 3))                    # 0.065
print(round(float(-10 * np.log10(1 - j0(2 * k_b * a))), 1))    # 11.9 dB less
```

The transfer mobility $Y_k$ of Formula (19e) is not a plate quantity at all: it
is the dynamic transfer stiffness of the mount, measured on the
[ISO 10846 rig](https://docs.jmrp.io/phonometry/vibration/structural/transfer-stiffness/). The fixing
position and the mount's data sheet both belong in the report's `notes`, because
they are the two things that make a repeat prediction reproducible.

### Table F.1: the tapping machine as a substitution source

When the equipment itself cannot be characterised, clause D.1.2.3 lets you
measure the building's transmission with a source whose force level is known
and substitute the equipment into it afterwards (Formula D.6). The ISO tapping
machine is the practical choice on low-mobility receiving structures, and
Table F.1 is its octave-band force level:

| Octave band [Hz] | 31.5 | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 |
| --- | --- | --- | --- | --- | --- | --- | --- | --- |
| $L_\mathrm{F}$ [dB] | 139 | 142 | 145 | 148 | 151 | 154 | 156 | 156 |

Two conditions travel with the table. The closed form the standard prints
beside it, $L_\mathrm{F} = 10\log_{10}(2.5f/10^{-12})$ in octave bands and
$10\log_{10}(0.8f/10^{-12})$ in one-third-octave bands
(`tapping_machine_force_level_estimate`), holds only "up till
about 1000 Hz": it gives 157 dB and 160 dB at 2 kHz and 4 kHz where the table
flattens at 156 dB, so read the table where the table exists and the closed
form only for the one-third-octave bands it does not tabulate. And the levels
are re $10^{-6}$ N despite the "re 1 pN" the caption prints; see the
[errata registry](https://docs.jmrp.io/phonometry/reference/errata/).

Clause D.1.3 then treats the machine as a force source with the mass-like
mobility of its 0.5 kg hammers, which turns the table into the two inputs this
page takes: $L_\mathrm{Ws,c} = L_\mathrm{F} - 5 - 10\log_{10}f$ (Formula D.9a) and
$D_{\mathrm{C},i} = -10\log_{10}(\omega M Y_i) + 10\log_{10}[1 + (\omega M Y_i)^2]$
(Formula D.9b, which is Formula 19b with $Y_\mathrm{s} = 1/\mathrm{j}\omega M$).

```python
import numpy as np
from phonometry import building

bands = np.array(building.TABLE_F1_OCTAVE_BANDS_HZ)
lf = building.tapping_machine_force_level()            # Table F.1
lw_c = building.tapping_machine_characteristic_power_level(lf, frequency=bands)
print(np.round(lw_c, 1))   # [119. 119. 119. 119. 119. 119. 118. 115.]

# Onto the 220 mm concrete floor of the previous section (Y_i = 1.07e-6).
dc = building.tapping_machine_coupling_term(1.07e-6, frequency=bands)
print(np.round(lw_c - dc, 1))   # [79.3 82.3 85.3 88.3 91.3 94.3 96.3 96.3]
```

In one-third-octave bands the characteristic power comes out flat at 114 dB
re 1 pW, which is Formula (D.9a)'s own "$\approx 115$ dB" and the flat thick
curve of the standard's Figure D.3.

## 2. Transmission to the receiving room

EN 12354 parts 1 and 2 handle rooms excited through the air and by the
standard tapping machine; part 5 covers the sources that shake the building
*directly*: pumps, fans, lifts, whirlpool baths, cisterns and the pipework
that ties them into walls and floors. Once the installed power is in the
structure, several elements radiate into the receiving room: the excited
element itself and every element the vibration reaches across the junctions.
Each excited-element/radiating-element pair $i \to j$ is a transmission path with
its own adjustment term and flanking index:

![EN 12354-5 installation paths: a pump on resilient mounts injects structure-borne power into the floor slab, the excited floor radiates into the receiving room below, a second path travels along the slab into the flanking wall, and the prediction cascade runs from the characteristic power to the normalised sound pressure level](https://docs.jmrp.io/phonometry/media/diagram_installed_paths.svg)

The diagram draws the simple case, one junction between the excited element and
the radiator. In parts 1 and 2 the two rooms always share the separating element,
and clause 4.2.4 of ISO 12354-1 says in so many words that the model describes
transmission between *adjacent* rooms. Service equipment breaks that assumption
routinely: the standard's own flushing-cistern example puts the receiving room
diagonally below the bathroom, and a riser or a lift shaft can be three junctions
away from whoever complains. Annex F.1 says what to do. $K_{ij}$ then stops being
the invariant of one junction and has to be read as covering the whole chain: the
junction indices add along the path (Formula F.1), the intermediate elements'
equivalent absorption lengths may be taken numerically equal to their areas as a
first estimate for large or well-damped elements, and an adjustment $\Delta K$
covers the longitudinal and in-plane waves that bending-wave theory misses
(about 4 dB for two junctions and 6 dB for three or more, which
`multi_junction_adjustment` returns), with the chained $K_{ij}$ floored near
$-5$ dB (`MIN_MULTI_JUNCTION_KIJ`), which corresponds to total structure-borne
transmission. Two consequences for the input you supply here: an
$R_{ij,\mathrm{ref}}$ computed for a single junction over-predicts the insulation
of a multi-junction route, and several distinct routes usually join the same
element pair, each of which must be counted as its own path or folded into one
effective $R_{ij,\mathrm{ref}}$ first. Where the paths become many, Annex F.1
points at a full SEA model instead.

Each transmission path $i \to j$ gives a normalised sound pressure level from the
installed power, the structure-to-airborne adjustment term $D_\mathrm{sa}$, the flanking
sound reduction index $R_{ij,\mathrm{ref}}$ (EN 12354-1) and the element area
(Formula 18a):

$$
L_{\mathrm{n,s},ij} = L_{\mathrm{Ws,inst},i} - D_{\mathrm{sa},i} - R_{ij,\mathrm{ref}}
             - 10\log_{10}\frac{S_i}{S_0} - 10\log_{10}\frac{A_0}{4},
$$

with $S_0 = A_0 = 10\ \text{m}^2$. Read the five terms in order, because each one
undoes a different normalisation. $L_{\mathrm{Ws,inst},i}$ is the power that
actually entered element $i$. $D_{\mathrm{sa},i}$ converts that structural excitation into
the equivalent *airborne* excitation, so that the next term may be an airborne
quantity at all. $R_{ij,\mathrm{ref}}$ is that airborne flanking index, defined
for a reference element of $S_0 = 10\ \text{m}^2$. $10\lg(S_i/S_0)$ therefore
puts the real element back: the same injected power spread over a larger element
gives a smaller vibration amplitude per unit area, so a bigger $S_i$ lowers the
radiated level. And $10\lg(A_0/4)$ turns radiated power into a reverberant sound
pressure level, through the diffuse-field relation
$p^2 = 4\rho_0c_0W/A$ evaluated at the reference absorption area $A_0$. That last
term is what "normalised" means on this page: the result is the level the room
*would* have if its equivalent absorption area were 10 m². A real room with more
absorption than that measures lower; ISO 16032 field measurements of service
equipment are usually *standardised* instead, referred to a reverberation time of
0.5 s, and the two are not interchangeable.

The paths then combine energetically, band by band (Formula 17):

$$
L_\mathrm{n,s} = 10\log_{10}\sum_{ij} 10^{L_{\mathrm{n,s},ij}/10}.
$$

`res.total_level` is that per-band combination and `res.overall_level` the sum
over the spectrum of it. For the flushing cistern of Annex I.3 the four paths
total 41.4 dB at 63 Hz and the whole spectrum closes at 29 dB(A); see the
weighting note below the snippet.

### The adjustment term $D_\mathrm{sa}$

A point force pumps energy into *free* bending waves, while an incident sound
field drives *forced* waves as well. $D_\mathrm{sa}$ is the bookkeeping factor that
lets the airborne flanking index $R_{ij,\mathrm{ref}}$ (an airborne
quantity) be reused for a structurally excited element: it converts the
injected structure-borne power into the incident airborne power that would
leave the element with the same free-vibration energy (Formula 20a). For
perpendicular force excitation of a homogeneous element that becomes
Formula (20b),

$$
D_{\mathrm{sa},i} = 10\log_{10}\frac{2\pi m_i\,2.2\,\tau_i}{\rho_0 c_0 T_{\mathrm{s},i}\sigma_i}\ \text{dB},
$$

with $R_i = -10\log_{10}\tau_i$, and Annex F.2 gives the working form

$$
D_{\mathrm{sa},i} = 10\log_{10}\frac{400\,f_{\mathrm{c},i}\,\sigma_i}{m_i\,f^2}\ \text{dB}
\qquad\text{(Formula F.3)},
$$

exact above the critical frequency ($\sigma_i \approx 1$) and a good
approximation over the whole range. Read it: heavier elements and higher
frequencies make $D_\mathrm{sa}$ *more negative*, at $-20\log_{10}f$ once $\sigma$
has saturated.

**Caution**

**$D_\mathrm{sa}$ is normally negative: pass the tabulated value with its printed
sign.**
The standard's own Annex I columns run from about $-14$ dB at 63 Hz to $-45$ dB
at 2 kHz for ordinary concrete and masonry elements. The term enters
Formula (18a) with a minus sign, so a negative $D_\mathrm{sa}$ *raises* the predicted
level. Earlier revisions of this page passed `"adjustment_term": 5.0` and
`6.0`; copying that pattern with a real Annex F value in its place would leave
the prediction roughly 20 to 40 dB low across the spectrum, with no error
raised.

Every input of Formula (F.3) is already available:
[`in_situ_element`](https://docs.jmrp.io/phonometry/buildings/design/detailed-prediction/#in_situ_element-parameters)
returns the in-situ structural reverberation time, the radiation factor and $R$
for the element, and `structure_to_airborne_adjustment` is Formula (F.3)
itself.

```python
import numpy as np
from phonometry import building

# Formula (F.3) for the 92 kg/m2 wall of the Annex I worked building.
f = np.array([63.0, 125.0, 250.0, 500.0, 1000.0, 2000.0])
sigma = np.minimum(1.0, np.sqrt(f / 200.0))        # radiation factor, fc = 200 Hz
dsa_f3 = building.structure_to_airborne_adjustment(
    f, critical_frequency=200.0, mass_per_area=92.0, radiation_factor=sigma
)
print(np.round(dsa_f3, 1))    # [-9.1 -13.6 -18.6 -24.6 -30.6 -36.6]  all negative

bands = np.array([250.0, 500.0, 1000.0])
res = building.installed_source_prediction(
    characteristic_power_level=np.array([80.0, 82.0, 78.0]),
    coupling_term=np.array([9.0, 10.0, 11.0]),
    paths=[
        {"adjustment_term": np.array([-19.0, -25.0, -31.0]),
         "flanking_reduction_index": np.array([50.0, 52.0, 55.0]), "element_area": 12.0},
        {"adjustment_term": np.array([-22.0, -28.0, -34.0]),
         "flanking_reduction_index": np.array([52.0, 54.0, 57.0]), "element_area": 8.0},
    ],
    frequencies=bands,
)
print(np.round(res.total_level, 1))      # total L_n,s per band
print(round(res.overall_level, 1))       # band-summed level [dB]

res.plot()   # the per-path and total L_n,s cascade, as in the figure above (needs matplotlib)
```

The `InstalledSourceResult` carries the per-path levels, the total per band, the
installed power level and `.overall_level`, and its `.plot()` draws the whole
cascade.

### `overall_level` is not the number a regulation limits

`overall_level` is the plain energetic sum of the per-band $L_\mathrm{n,s}$ over the
bands you supplied. It is **not** A-weighted, and the quantity every national
requirement for service-equipment noise is written in (and the quantity the
ISO 16032 field measurement produces) is the A-weighted single number
$L_\mathrm{n,s}(A)$. Both of EN 12354-5's worked examples close on one: 26 dB(A) for the
Annex I.2 whirlpool bath and 29 dB(A) for the Annex I.3 cistern. The gap is not
small. Service-equipment spectra are weighted to the low bands, exactly where the
A-weighting is steepest, so for the Annex I.3 cistern the unweighted sum is
44.0 dB against the standard's 29 dB(A) (fifteen decibels of headroom that does
not exist). Weight the band levels before summing them:

```python
import numpy as np

# Annex I.3 total per octave band, and the A-weighting corrections for those
# nominal centres (ISO 3744 Annex E Table E.2 / IEC 61672-1).
l_ns = np.array([41.4, 39.6, 30.5, 28.9, 18.5, 4.4])       # 63 Hz to 2 kHz
a_corr = np.array([-26.2, -16.1, -8.6, -3.2, 0.0, 1.2])
print(round(float(10 * np.log10(np.sum(10 ** (0.1 * l_ns)))), 1))            # 44.0 dB
print(round(float(10 * np.log10(np.sum(10 ** (0.1 * (l_ns + a_corr))))), 1))  # 29.3 dB(A)
```

Read a result against that scale, not against the unweighted total: 29 dB(A) for a
cistern and 26 dB(A) for a whirlpool bath are what the standard's own conforming
examples produce, and dwelling limits for service equipment usually sit in the
low thirties.

## 3. The prediction report (`.report()`)

A prediction ends as a *document*. The `InstalledSourceResult` exposes a
`.report()` method that writes a one-page PDF fiche, **clearly labelled a
prediction, not a measurement**: a prediction-basis line naming
EN 12354-5:2009, an optional metadata header (client, source equipment,
receiving room, instrumentation, climate, date), a per-band table (nominal
octave/one-third-octave frequency, the installed structure-borne power level
$L_\mathrm{Ws,inst}$, each transmission path's normalised SPL $L_{\mathrm{n,s},ij}$ and the
combined total $L_\mathrm{n,s}$), the per-path and total $L_\mathrm{n,s}(f)$ spectra, and a
boxed band-summed total $L_\mathrm{n,s}$ (dB) with the installed power total and the
path count.

The metadata is supplied through a `ReportMetadata`, whose applicable fields
here are the **source equipment** (`specimen`), the **receiving room**
(`test_room`), the **client**, the **instrumentation** and the footer identity
(`laboratory`, `operator`, `report_id`, `notes`). Supplying `requirement` adds a
PASS/FAIL verdict against a declared upper limit on the overall $L_\mathrm{n,s}$ (less
is better). `verbose=True` adds one column per transmission path (up to five);
otherwise only the installed power and the combined total are shown.
`language="es"` renders the Spanish fiche with comma decimals. The basis strip
states Formulae 18a/17 and the prediction disclaimer. Rendering needs reportlab and, for the figure the fiche embeds, matplotlib
(`pip install "phonometry[report,plot]"`).

Two numbers in the snippet below are the standard's, not invented: `16.2` is the
coupling term of the Annex I.3 cistern at its wall contact, and the `lwc` array is
that cistern's characteristic power level, the 84.4 dB the
[EN 15657 page](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/) derives at
63 Hz. `requirement` is compared against `overall_level`, so the 45 dB below is an
*unweighted* band-sum limit; a regulation stated in dB(A) has to be checked
against the A-weighted sum of the previous section instead, and against this
example's spectrum the two differ by about 15 dB.

```python
import numpy as np
from phonometry import ReportMetadata, building

bands = np.array([63, 125, 250, 500, 1000, 2000], float)
lwc = np.array([84.4, 82.5, 69.9, 67.6, 61.6, 49.9])   # characteristic power [dB]
dsa = np.array([-13.6, -17.3, -17.4, -20.0, -26.9, -32.9])
paths = [
    {"adjustment_term": dsa,
     "flanking_reduction_index": np.array([43.0, 46, 50.2, 54.7, 64.6, 73]),
     "element_area": 12.8},
    {"adjustment_term": dsa,
     "flanking_reduction_index": np.array([37.0, 41.2, 35.9, 37.7, 49, 57.8]),
     "element_area": 12.8},
]
res = building.installed_source_prediction(lwc, 16.2, paths, frequencies=bands)

res.report(
    "installed_structure_borne.pdf",
    metadata=ReportMetadata(
        client="Example dwelling refurbishment",
        specimen="WC flushing cistern (wall-fixed)",
        test_room="Receiving room: adjacent bedroom",
        report_id="EXAMPLE-12354-5",
        requirement=45.0,
    ),
)   # overall L_n,s ~ 43 dB -> declared limit 45 dB: PASS
```

The example fiche is regenerated with `make reports` and kept rendered in the
repository; click the preview to open the PDF.

**Report:** [EN 12354-5 installed structure-borne prediction example report (PDF)](https://docs.jmrp.io/phonometry/media/en12354_5_installed_structure_borne_example.pdf): One-page EN 12354-5:2009 installed structure-borne sound prediction fiche, clearly labelled a prediction and not a measurement: a header with the client, the source equipment, the receiving room and the identity, the octave-band table (63 Hz to 2 kHz) of the installed structure-borne power level L_Ws,inst, the two flanking paths' normalised SPL L_n,s,ij and the combined total L_n,s, the per-path and total L_n,s(f) spectra, and the boxed band-summed total L_n,s with the installed power total and the path count, closed by a basis strip stating Formulae 18a/17 and the prediction disclaimer, with a PASS verdict against the declared 45 dB limit.

Installed structure-borne prediction fiche (InstalledSourceResult.report), an EN 12354-5 estimate of the normalised structure-borne SPL in the receiving room.

## What this guide covers

- **Covered.** EN 12354-5:2009: the coupling term $D_\mathrm{C}$ (clause 4.4.3, Formulae 19b-e, with
  its force-source and velocity-source limits) via `coupling_term`, the
  installed power level $L_\mathrm{Ws,inst} = L_\mathrm{Ws,c} - D_\mathrm{C}$ (Formula 18b)
  via `installed_structure_borne_power_level`, and the per-path normalised sound
  pressure level and its energetic total (Formulae 18a, 17) via
  `installed_source_prediction`. Validated against the standard's own Annex I
  worked examples, the whirlpool bath (I.2) and the flushing cistern (I.3),
  within the ±0.15 dB rounding of the printed intermediates. The informative
  tables of the annexes are here too: Table D.1 (mobility of typical
  construction elements) via `typical_element_mobility`, Table F.1 (force level
  of the ISO tapping machine) via `tapping_machine_force_level` with Formulae
  (D.9a) and (D.9b), the adjustment term of Formula (F.3) via
  `structure_to_airborne_adjustment`, and the multi-junction $\Delta K$ of
  clause F.1 via `multi_junction_adjustment`.

- **Not covered.** The flanking reduction index $R_{ij,\mathrm{ref}}$ is an input you supply from
  measurement or from EN 12354-1; Annex F.1 gives only the multi-junction
  correction to it, not the index itself. Formula (F.1) for the equivalent
  $K_{ij}$ over several junctions, the SEA route of Formula (F.2) and the
  mobility corrections for excitation near a border or corner (Formulae F.6a and
  F.6b) are not implemented. Only the 2009 edition is implemented, not the 2023
  revision.

## See also

- [Structure-borne sound power of equipment (EN 15657)](https://docs.jmrp.io/phonometry/buildings/design/structure-borne-power/):
  the reception-plate characterisation that supplies $L_\mathrm{Ws,c}$ and the source
  mobility this prediction consumes.
- [Mechanical mobility and the FRF family (ISO 7626-1)](https://docs.jmrp.io/phonometry/vibration/structural/mechanical-mobility/):
  the measured $Y_\mathrm{s}$ and $Y_i$ behind the coupling term.
- [Bending-wave transmission at plate junctions](https://docs.jmrp.io/phonometry/vibration/structural/junction-transmission/):
  the junction physics that carries the installed power to the flanking
  radiators.
- [Predicting Sound Insulation (EN 12354)](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/):
  the airborne and impact members of the same prediction family.
- API reference: [`building.prediction.installed_structure_borne`](https://docs.jmrp.io/phonometry/reference/api/building/installed-structure-borne/).
- Theory: [Point mobilities and radiation efficiency](https://docs.jmrp.io/phonometry/reference/theory/vibration/#point-mobilities-and-radiation-efficiency-cremer-5-hopkins-29): the mobility and radiation-efficiency theory the installed level is predicted from.

## References

- **Cremer, L., Heckl, M., & Petersson, B. A. T. (2005).** *Structure-borne sound: Structural vibrations and sound radiation at audio frequencies* (3rd ed.). Springer. https://doi.org/10.1007/b137728
  The source-receiver mobility coupling and the structure-borne transmission across junctions behind the coupling term and the path model. ISBN 978-3-540-22696-3.
- **European Committee for Standardization. (2009).** [*Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 5: Sound levels due to service equipment*](https://knowledge.bsigroup.com/products/building-acoustics-estimation-of-acoustic-performance-of-building-from-the-performance-of-elements-sounds-levels-due-to-the-service-equipment) (EN 12354-5:2009).
  The coupling term (clause 4.4.3, Formulae 19a-19e), the installed structure-borne power level (Formula 18b), the structure-to-airborne adjustment term (clause 4.4.4, Formulae 20a/20b), and the normalised sound pressure level per path and its energetic combination (Formulae 18a, 17). Conformance is anchored on the coupling-term force-source limit and the standard's own Annex I worked examples: the whirlpool bath of I.2 (Table I.6a: mobility correction and path 11) and the flushing cistern of I.3 (Tables I.8/I.9: source conversion, all four transmission paths, the Formula 17 total and its 29 dB(A) closure), within the ±0.15 dB rounding of the printed one-decimal intermediates. D_sa and R_ij,ref are inputs (from measurement / EN 12354-1 / Annexes D and F). The linked catalogue record is the BSI Knowledge page for BS EN 12354-5:2009; since revised as EN 12354-5:2023 (https://knowledge.bsigroup.com/products/building-acoustics-estimation-of-acoustic-performance-of-buildings-from-the-performance-of-elements-sounds-levels-due-to-the-service-equipment).
- **Hopkins, C. (2007).** *Sound insulation*. Butterworth-Heinemann. https://doi.org/10.4324/9780080550473
  Section 2.8 (driving-point impedance and mobility): the power a mechanical source injects into a plate through the source and receiver mobilities, the building-acoustics reading of the clause 4.4.3 coupling term. ISBN 978-0-7506-6526-1.
- **International Organization for Standardization. (2017).** [*Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 1: Airborne sound insulation between rooms*](https://www.iso.org/standard/70242.html) (ISO 12354-1:2017).
  Where a calculated flanking reduction index R_ij,ref comes from, and clause 4.2.4, which confines the model to adjacent rooms; the detailed model is implemented in the detailed-prediction guide.