# Floor-Covering Impact Improvement (ISO 16251-1)

> One page of the phonometry documentation, as Markdown. Index: https://docs.jmrp.io/phonometry/llms.txt

Canonical: https://docs.jmrp.io/phonometry/buildings/design/impact-improvement/
Language: en
Alternate: https://docs.jmrp.io/phonometry/es/buildings/design/impact-improvement/index.md
Version: phonometry 4.0.0
Install: pip install "phonometry[full]"
Author: José Manuel Requena Plens (https://orcid.org/0000-0003-1250-6212)
Published: 2026-07-28
Updated: 2026-11-16T21:36:14Z
Standards: ISO 16251-1:2014; ISO 717-2:2020; ISO 12354-2:2017
Verified: 13 conformance checks (ISO 16251-1:2014; ISO 717-2:2020; ISO 12354-2:2017) https://docs.jmrp.io/phonometry/reference/conformance/#room-building-acoustics
License: MIT (https://github.com/jmrplens/phonometry/blob/main/LICENSE)
Summary: Floor-covering impact improvement on the ISO 16251-1 mock-up: acceleration levels, ISO 717-2 weighted improvement, fiche and ISO 12354-2 estimate.

---

A soft floor covering does not block airborne sound; it cushions footsteps.
What it improves is the impact level of the floor underneath, and measuring
that improvement in a full ISO 10140 transmission suite is out of proportion
to a square metre of carpet. ISO 16251-1 therefore shrinks the laboratory to
a small heavyweight mock-up: a softly supported concrete plate, a standard
tapping machine and an accelerometer underneath. This guide covers the
mock-up measurement of the improvement $\Delta L$ and its weighted
$\Delta L_\mathrm{w}$ against the ISO 717-2 reference floor, the accredited fiche,
and the ISO 12354-2 engineering estimate that predicts a floating floor's
improvement from the dynamic stiffness of its resilient layer. The
full-size laboratory chain lives in
[Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/); the
$s'$ measurement behind the estimate is the subject of
[Dynamic stiffness of resilient materials](https://docs.jmrp.io/phonometry/materials/resilient/dynamic-stiffness/).

## The small-mock-up method

ISO 16251-1:2014 is a laboratory method for the **improvement of impact sound
insulation** $\Delta L$ of a soft, locally-reacting floor covering (carpet, PVC,
linoleum). The two ISO 10140 rooms are replaced by a small softly-supported
concrete plate; a standard tapping machine excites it and the structure-borne
**acceleration level** on the underside is measured with and without the
covering. For locally-reacting coverings that acceleration-level difference
equals the ISO 10140 impact sound reduction.

### "Locally reacting" is the condition the whole method rests on

Clause 3.3 defines it: a covering is **locally reacting** when the impact is
transmitted into the bearing floor *predominantly through the area the hammers
directly excite*. The energy does not spread sideways through the covering
itself, so (as the standard's own note says) the improvement does not depend on
the size of the specimen. That single property is what lets a
120 cm × 80 cm plate stand in for a full transmission suite: if a 1 m² sample and
a 20 m² floor give the same $\Delta L$, the small rig is not an approximation of
the large one, it is the same measurement.

The qualifying family is named in the scope: soft, flexible coverings (carpets,
PVC and linoleum), which map onto ISO 10140-1:2021 Annex H, **category I**. The
disqualifying family is anything with a stiff wearing layer that distributes the
hammer load over an area the specimen's own size then bounds: laminates, click
systems, and any floating floor, whose screed is precisely a load-spreading
plate. The standard states the consequences plainly. For non-soft, non-flexible
floorings "increased deviations from the results of the ISO 10140 series method
may occur due to the dependency on the specimen size"; and **in the case of
difference with ISO 10140, the result of the ISO 10140 measurement shall be
used**. The mock-up never overrules the full-size suite.

One rating rule follows from the same clause. Where more than one sample of the
same product is tested, the per-band $\Delta L$ of the samples are **arithmetically
averaged first, and ISO 717-2 is applied to the average** (Clause 6.5). Rating
each sample and averaging the ratings is a different number and is not what the
standard asks for.

### The rig, and why every dimension of it is in the standard

Annex A is normative and consists of two setup drawings. The slab is
(120 ± 5) cm × (80 ± 5) cm × (20 ± 1) cm, homogeneous and of uniform thickness,
flat to ± 1 mm along a horizontal line from edge to edge and hard enough to
endure the hammers; a screed may be added to provide the flatness. It rests on
four elastic supports at the corners, none exceeding 10 cm × 10 cm, and the
vertical resonance of the slab on those bearings shall lie **below 20 Hz**. At
least four accelerometer positions are screwed or glued to the lower surface,
uniformly but randomly distributed, avoiding symmetric lines and at least 10 cm
from the edges. The tapping machine takes at least two positions, at least 30 cm
apart, skew to the edges, with no hammer closer than 10 cm to an edge and all
four feet standing on the specimen.

Each of those numbers is doing something. The 20 cm thickness reproduces the
ISO 10140 standard heavyweight floor, which is what makes the improvement
transferable to a real building. The sub-20 Hz support resonance puts the whole
measurement range above the rigid-body modes, so the plate behaves as a free
body and its acceleration reflects only the force the hammers inject. The
flatness matters because $\Delta L$ is the ratio of two force inputs and an
uneven surface changes how the hammers strike. The edge clearances and the
randomised, asymmetric positions keep the four-position average from landing on a
nodal line of the plate's own modes. And the four accelerometer levels and two
machine positions are not decoration: Formula (4) averages $\Delta L$ over the
$t \times a$ pairs, which is exactly what `impact_improvement` consumes.

![The ISO 16251-1 small floor mock-up: a section through the 200 mm concrete slab on its four elastic pads with the covering specimen and the tapping machine, a plan of the 1200 by 800 mm slab with the two machine positions and four accelerometer positions and their clearances, and the three measurement cycles](https://docs.jmrp.io/phonometry/media/diagram_iso16251_mockup.svg)

The instrument chain is specified too (Clause 5.2): the measurement system shall
be declared to meet IEC 61672-1 class 1 with the microphone replaced by the
accelerometer, the one-third-octave filters IEC 61260 class 1, the tapping
machine ISO 10140-5, and the vibration calibration ISO 16063. The standard warns
that the bare plate's acceleration signal is a train of extremely short pulses
which some otherwise-compliant chains handle badly, and asks for a first-use
check against an ISO 10140 measurement. Three cycles are recorded: with the
specimen, without it (hammer positions repeating within ± 2 cm) and background,
each averaged for **not less than 20 s**, with temperature and humidity noted
before and after and the chain calibrated before and rechecked after.

None of this is checked by the library, which starts from the measured
acceleration levels: conformity of the facility is the operator's to demonstrate.

**Acceleration level (Formula (1)).** $L_a = 10\log_{10}(\langle a^2\rangle / a_0^2)$ dB,
reference $a_0 = 10^{-6}\ \text{m/s}^2$. **Background correction (Formula (2))**
follows the ISO 10140 three-branch rule (unchanged ≥ 15 dB; energy subtraction
for 6 ≤ margin < 15 dB; the 1.3 dB limit below 6 dB, flagged as $> \Delta L$).
The improvement is the position-averaged difference
$\Delta L = L_0 - L_1$ (Formulae (3)/(4)); octaves follow
$\Delta L_\mathrm{oct} = -10\log_{10}[\tfrac{1}{3}\sum 10^{-\Delta L_j/10}]$ (Formula (5)).

![ISO 16251-1 background correction of a textile carpet on the mock-up: the margin of the reading above a 20 dB accelerometer background in each one-third-octave band from 100 Hz to 3150 Hz, over the three shaded regimes of Formula (2), clear above 15 dB up to 630 Hz, background subtracted at 800 Hz and 1 kHz, and held at the 1.3 dB limit of measurement in the five highest bands](https://docs.jmrp.io/phonometry/media/background_corrected_level.svg)

*The textile carpet of this page, read with the covering on over an accelerometer background of 20 dB re 1 µm/s². Up to 630 Hz the reading clears the background by 15 dB or more and is used as it is; at 800 Hz and 1 kHz the background is subtracted in energy; from 1250 Hz up the margin is under 6 dB, and the correction is held at 1.3 dB. Those five bands are reported as $> \Delta L$: the covering improves them by at least that much, and the mock-up cannot say by how much more.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import building

freqs = [100, 125, 160, 200, 250, 315, 400, 500,
         630, 800, 1000, 1250, 1600, 2000, 2500, 3150]
bare = np.array([72, 73, 74, 74, 75, 75, 76, 76, 77, 77, 78, 78, 79, 79, 80, 80])
covering = bare - np.array([5, 8, 10, 14, 18, 23, 30, 31,
                            39, 49, 53, 57, 60, 67, 68, 71])
background = np.full(16, 20.0)   # dB re 1 um/s^2
# What the accelerometer reads with the carpet on: the covering plus the background.
reading = 10 * np.log10(10 ** (covering / 10) + 10 ** (background / 10))
res = building.background_corrected_level(reading, background, frequencies=freqs)
print(int(res.limited.sum()))    # 5 bands at the 1.3 dB limit
res.plot()
plt.show()
```

**Weighted improvement.** $\Delta L_\mathrm{w}$ is the ISO 717-2 weighted reduction: the
improvement is applied to the heavyweight **reference floor** $L_\mathrm{n,r,0}$
(ISO 717-2 Table 4), $L_\mathrm{n,r} = L_\mathrm{n,r,0} - \Delta L$, and
$\Delta L_\mathrm{w} = 78 - L_\mathrm{n,r,w}$, computed by `weighted_impact_improvement()`, which
reuses the verified ISO 717-2 rating engine. A clause 6.3 measurement spans 18
bands (100–5000 Hz, optionally extended to 50 Hz); the rating is formed on the
100–3150 Hz sub-range of whatever spectrum contains it. The statement of
results (clause 8 e)) also carries the spectrum adaptation term
$C_{\mathrm{I},\Delta} = C_\mathrm{I,r,0} - C_\mathrm{I,r}$ (ISO 717-2:2020 Formula (A.4)), exposed as
`ci_delta` on the result and standalone as
`impact_improvement_adaptation_term()`.

The worked example below is a real measurement: a textile carpet on the CSTB
heavyweight mock-up, its improvement spectrum digitized from Figure 4 of Foret,
Chéné and Guigou-Carter (2011). The paper publishes
$\Delta L_\mathrm{w} = 29$ dB for it, and the rating engine returns exactly that.

**And $C_{\mathrm{I},\Delta}$ is half the answer, so read it.** The weighted rating slides
a reference curve until the excess fits, which rewards improvement wherever in
the spectrum it happens; real footfall noise is dominated by the low and mid
bands, where a thin resilient covering does least. $C_\mathrm{I}$ is the adaptation term
that compares the *unweighted* energetic sum with the weighted rating, and
$C_{\mathrm{I},\Delta} = C_\mathrm{I,r,0} - C_\mathrm{I,r}$ contrasts the reference floor as it is
against the reference floor with the covering on it, with $C_\mathrm{I,r,0}$ fixed at
$-11$ dB (A.2.2; $-10.3$ dB when one decimal is required). Formula (A.5) then
says what the pair means:
$\Delta L_\mathrm{lin} = \Delta L_\mathrm{w} + C_{\mathrm{I},\Delta}$. This page's carpet is rated
29 ($-13$) dB, so on the flat-response scale it buys **16 dB**, not 29. A
strongly negative $C_{\mathrm{I},\Delta}$ is the signature of a covering that works only
high up, typical of thin resilient layers, and exactly where the tapping machine
flatters them; a covering with $C_{\mathrm{I},\Delta}$ near zero improves the whole range.
A fiche that prints only $\Delta L_\mathrm{w}$ has told you the better half of the story.

![ISO 16251-1 floor-covering impact sound improvement: the improvement delta-L of a soft carpet rising with frequency across one-third-octave bands from 100 Hz to 3150 Hz, with the shaded improvement area and the weighted single-number delta-Lw annotated](https://docs.jmrp.io/phonometry/media/floor_covering_improvement.svg)

*A real textile carpet on the mock-up, and the shape is the whole argument: 5 dB
at 100 Hz against 71 dB at 3150 Hz, a span of 66 dB across the rated range. The
covering does almost nothing to the low-frequency thump and almost everything to
the high-frequency click. $\Delta L_\mathrm{w}$ = 29 dB records that only obliquely,
which is why the figure is read together with $C_{\mathrm{I},\Delta} = -13$ dB and the
16 dB that the two of them give on the flat-response scale.*

**Show the code for this figure**

```python
import matplotlib.pyplot as plt
import numpy as np
from phonometry import building

freqs = [100, 125, 160, 200, 250, 315, 400, 500,
         630, 800, 1000, 1250, 1600, 2000, 2500, 3150]
bare = np.full(16, 78.0)                       # bare-plate acceleration level
# A real textile carpet measured on the CSTB mock-up (Foret et al. 2011, Fig. 4).
covering = bare - np.array([5, 8, 10, 14, 18, 23, 30, 31,
                            39, 49, 53, 57, 60, 67, 68, 71])
res = building.impact_improvement(bare, covering, frequencies=freqs)
print(res.delta_lw)   # weighted improvement delta-Lw = 29 dB (ISO 717-2)
res.plot()
plt.show()
```

```python
from phonometry import building

# delta-Lw straight from an improvement spectrum (16 one-third-octave bands):
delta_l = [5, 8, 10, 14, 18, 23, 30, 31, 39, 49, 53, 57, 60, 67, 68, 71]
print(building.weighted_impact_improvement(delta_l))    # 29 dB (carpet)

# Two samples of the same product: average the per-band improvements FIRST,
# then rate the average (Clause 6.5). Rating each sample and averaging the
# ratings is a different number.
import numpy as np
sample_a = np.array(delta_l, dtype=float)
sample_b = sample_a + np.array([1, 0, -1, 1, 0, -1, 1, 0, -1, 1, 0, -1, 1, 0, -1, 1])
print(building.weighted_impact_improvement(0.5 * (sample_a + sample_b)))   # 29 dB

# From the measured bare/covered acceleration levels, with a background trace:
freqs = [100, 125, 160, 200, 250, 315, 400, 500, 630, 800,
         1000, 1250, 1600, 2000, 2500, 3150]
bare_levels = [72, 73, 74, 74, 75, 75, 76, 76, 77, 77, 78, 78, 79, 79, 80, 80]
covered_levels = [b - d for b, d in zip(bare_levels, delta_l)]
bg = [40.0] * 16
res = building.impact_improvement(bare_levels, covered_levels, frequencies=freqs, background=bg)
res.improvement       # delta-L per band
res.delta_lw          # weighted single number (rated on the 100-3150 Hz sub-range)
res.ci_delta          # spectrum adaptation term CI,delta (Formula (A.4))
res.limited           # bands at the 1.3 dB limit of measurement (> delta-L)
res.octave_bands()    # .frequencies and .values (delta-L_oct) via Formula (5)
res.plot()            # the delta-L(f) improvement spectrum above (needs matplotlib)
```

## ISO 16251-1 impact-improvement report (`.report()`)

Clauses 8 and 9 decide what a result has to carry to be reportable, and most of
it is yours to supply rather than the library's to compute. Beside the
improvement itself the table must show the **bare-plate acceleration level
$L_{a,0}$** with its reference $a_0$, the per-band $\Delta L$ of *every* sample
tested, their average where there is more than one, the weighted improvement(s)
and the adaptation term(s), all rounded to **one decimal place**, with any
band whose background correction hit the 1.3 dB limit written as "> $\Delta
L$". The report then adds: the manufacturer and product identification, a
detailed description of the covering with the number and size of the specimens,
the **method of mounting, in particular the adhesive with its mass per area and
curing time**, the temperature and humidity during the test, the **positions of
the tapping machine and the accelerometers**, and a statement of whether the
specimen suffered visible damage such as compaction. Those map onto the
`manufacturer`, `specimen`, `mounting`, `mass_per_area`, `temperature_c`,
`static_pressure_kpa`, `test_date` and `notes` fields of `ReportMetadata`
below; the damage statement and the mounting detail have no field of their own
and belong in `notes`.

`FloorCoveringImprovementResult.report(path)` writes a one-page accredited
impact-improvement fiche: the standard-basis line, a metadata header, the
per-band table (frequency and $\Delta L$, bands at the 1.3 dB limit prefixed
`>`) beside the $\Delta L(f)$ improvement curve, the boxed single-number
$\Delta L_\mathrm{w}\ (C_{\mathrm{I},\Delta})$ (the ISO 16251-1 Clause 8 e)
statement of results), and a footer. Pass a `ReportMetadata` for the header;
the applicable fields are `specimen` (the floor covering under test), `client`,
`manufacturer`, `mounting`, `mass_per_area`, `test_room`, `test_date`,
`temperature_c`, `static_pressure_kpa`, `measurement_standard`, `laboratory`,
`operator`, `report_id`, `notes` and `requirement` (a higher weighted
improvement is better, so the verdict passes at or above it). The bare
reference floor is the standardised heavyweight floor of ISO 717-2:2020 Table
4, fixed by the standard. `verbose=True` adds the reference-floor-with-covering
column $L_\mathrm{n,r} = L_\mathrm{n,r,0} - \Delta L$, the derivation basis of
$\Delta L_\mathrm{w}$.

```python
from phonometry import building, ReportMetadata

freqs = [100, 125, 160, 200, 250, 315, 400, 500,
         630, 800, 1000, 1250, 1600, 2000, 2500, 3150]
delta_l = [5, 8, 10, 14, 18, 23, 30, 31, 39, 49, 53, 57, 60, 67, 68, 71]
bare = [78.0] * 16
res = building.impact_improvement(bare, [b - d for b, d in zip(bare, delta_l)], frequencies=freqs)
res.report("dLw.pdf",
           metadata=ReportMetadata(
               specimen="Textile floor covering (carpet), laid loose",
               measurement_standard="ISO 16251-1",
               requirement=20.0))  # delta-Lw (CI,delta) = 29 (-13) dB
```

The example fiche is regenerated with `make reports` and kept in the
repository. Click the preview to open the PDF:

**Report:** [Floor-covering impact improvement ISO 16251-1 example report (PDF)](https://docs.jmrp.io/phonometry/media/iso16251_floor_covering_example.pdf): One-page floor-covering impact-improvement test report for a soft carpet whose improvement spectrum is digitized from the Foret et al. (2011) ISO/CD 16251-1 comparison study (an illustrative example, not an accredited measurement): the metadata header (client, floor-covering description, mounting, mass per area, climate), the one-third-octave delta-L table beside the delta-L(f) improvement curve rising with frequency, the boxed delta-Lw (CI,delta) = 29 (-13) dB weighted improvement (ISO 717-2), and a PASS verdict against the 20 dB requirement (a higher weighted improvement is better).

Floor-covering impact-improvement fiche (FloorCoveringImprovementResult.report), delta-Lw (CI,delta).

## From dynamic stiffness to the improvement: the ISO 12354-2 estimate

The mock-up measures a *covering* that exists; a **floating floor** (a
screed poured on a resilient layer) is designed the other way round, from
two numbers known at the drawing stage: the mass per unit area $m'$ of the
slab and the dynamic stiffness per unit area $s'$ of the resilient layer,
measured per EN 29052-1 as in the
[dynamic-stiffness guide](https://docs.jmrp.io/phonometry/materials/resilient/dynamic-stiffness/). Together they set the mass-spring
resonance of the system (ISO 12354-2:2017, Annex C, Formula (C.2)):

$$
f_0 = 160 \sqrt{\frac{s'}{m'}}\ \text{Hz}
\qquad (s'\ \text{in MN/m}^3,\ m'\ \text{in kg/m}^2),
$$

where 160 is the rounded $1000/2\pi$; `materials.natural_frequency` computes
the exact $\tfrac{1}{2\pi}\sqrt{s'/m'}$ form. Above the resonance the slab
decouples from the structural floor and Annex C estimates the improvement as
a straight slope per Formula (C.1), with the steeper Formula (C.3) for
constructions whose higher internal losses follow the infinite-plate theory:

$$
\Delta L = 30 \log_{10} \frac{f}{f_0}\ \text{dB (sand/cement, calcium-sulfate screeds)},
\qquad
\Delta L = 40 \log_{10} \frac{f}{f_0}\ \text{dB (asphalt, dry screeds)}.
$$

Both are written for $f > f_0$ only, and taken as zero at and below the
resonance. That is a convention: in the band containing $f_0$ the mass-spring
system amplifies and measured floors fall between about $-5$ dB and $0$ dB
there, so a design whose $f_0$ lands inside the rated 100-3150 Hz range rates
optimistically in exactly the band that decides the number. Here $f_0$ is
52.8 Hz, comfortably below the range, which is why the spectrum below starts
clean at 100 Hz.

```python
import numpy as np
from phonometry import building, materials

# The ISO 12354-2:2017 Annex G worked floor: a 73.5 kg/m2 screed on a resilient
# layer with s' = 8 MN/m3.
f0 = 160.0 * np.sqrt(8.0 / 73.5)                                 # Formula (C.2)
print(round(f0, 1))                                              # 52.8  Hz
print(round(float(materials.natural_frequency(8.0e6, 73.5)), 1))  # 52.5  exact 1/(2 pi) form

# delta-L = 30 lg(f/f0) above the resonance (Formula (C.1)); build the
# one-third-octave spectrum and rate it with the ISO 717-2 engine.
freqs = np.array([100, 125, 160, 200, 250, 315, 400, 500, 630, 800,
                  1000, 1250, 1600, 2000, 2500, 3150], dtype=float)
delta_l = 30.0 * np.log10(freqs / f0)
print(building.weighted_impact_improvement(delta_l))             # 32  dB

# The one-line estimate of Formula (C.4) lands right beside it:
print(round(13.0 * np.log10(73.5) - 14.2 * np.log10(8.0) + 20.8, 1))   # 32.2 dB
```

The closed-form weighted estimate of Formula (C.4),
$\Delta L_\mathrm{w} = 13\log_{10} m' - 14.2\log_{10} s' + 20.8$ dB, condenses the same
physics into one line: heavier slabs and softer layers rate better. Both
estimates are design aids kept deliberately on the safe side (the 30 lg
slope undercuts the 40 lg infinite-plate theory where experimental data say
real screeds fall short); once a specimen exists, the measured mock-up of
this page, or the full ISO 10140-3 floor, is the reference, and the
[EN 12354-2 prediction](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/) consumes whichever $\Delta L_\mathrm{w}$ you have.

## What this guide covers

- **Covered.** ISO 16251-1:2014's acceleration level (Formula (1)), the three-branch
  background correction (Formula (2)), the position-averaged improvement
  $\Delta L$ (Formulae (3)/(4)) and its octave synthesis (Formula (5)), via
  `building.acceleration_level`, `building.background_corrected_level` and
  `building.impact_improvement`; the Clause 8 e) statement of results,
  $\Delta L_\mathrm{w}$ against the ISO 717-2 Table 4 reference floor with the
  $C_{\mathrm{I},\Delta}$ adaptation term (Formula (A.4)), via
  `building.weighted_impact_improvement` and
  `building.impact_improvement_adaptation_term`; and the one-page accredited
  fiche through `.report()`.

- **Not covered.** The mock-up facility itself (the plate dimensions, the resilient supports, the
  tapping-machine positions of Clause 5) is not checked: the functions consume
  measured acceleration levels wherever they came from. The ISO 12354-2:2017
  Annex C floating-floor formulas are quoted on this page as design aids and
  evaluated inline with numpy; the dedicated helpers that wrap them, together
  with the tapping-machine force model behind a soft covering's improvement and
  the ISO 12354-1 Annex D rating of a wall lining, are the subject of
  [Predicting Resilient-Layer
  Performance](https://docs.jmrp.io/phonometry/buildings/design/resilient-layers/). The superseded
  full-size ISO 140-8 method exists here only as the comparison axis of the
  Foret et al. (2011) worked example.

## See also

- [Laboratory Insulation Measurement](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-lab/):
  the ISO 10140 suite this mock-up replaces for soft coverings, and the
  full-size ISO 10140-3 improvement measurement.
- [Dynamic stiffness of resilient materials](https://docs.jmrp.io/phonometry/materials/resilient/dynamic-stiffness/):
  the $s'$ measurement that feeds the floating-floor estimate.
- [Predicting Resilient-Layer Performance](https://docs.jmrp.io/phonometry/buildings/design/resilient-layers/):
  the prediction counterpart of this page, from the tapping-machine force
  model to floating floors and wall linings.
- [Predicting Sound Insulation (EN 12354)](https://docs.jmrp.io/phonometry/buildings/design/insulation-prediction/):
  the impact model whose Formula (21) consumes $\Delta L_\mathrm{w}$.
- [Insulation Ratings (ISO 717)](https://docs.jmrp.io/phonometry/buildings/insulation/insulation-ratings/):
  the reference-curve engine behind the weighted improvement.
- [Theory](https://docs.jmrp.io/phonometry/reference/theory/rooms-buildings/): the
  reference-curve derivation behind the weighted single numbers.
- API reference: [`building.measurement.floor_covering_improvement`](https://docs.jmrp.io/phonometry/reference/api/building/floor-covering-improvement/).

## References

- **Foret, R., Chéné, J.-B., & Guigou-Carter, C. (2011).** A comparison of the reduction of transmitted impact noise by floor coverings measured using ISO 140-8 and ISO/CD 16251-1. *Forum Acusticum 2011, Aalborg (CSTB)*.
  The measured textile-carpet improvement spectrum used as the ISO 16251-1 worked example on this page (ΔL_w = 29 dB); the per-band ΔL was digitized from its Figure 4.
- **International Organization for Standardization. (1989).** [*Acoustics — Determination of dynamic stiffness — Part 1: Materials used under floating floors in dwellings*](https://www.iso.org/standard/16620.html) (EN 29052-1:1992 (ISO 9052-1:1989)).
  The measurement of the dynamic stiffness per unit area s' that the ISO 12354-2 Annex C estimate starts from; it is implemented in the dynamic-stiffness guide.
- **International Organization for Standardization. (2014).** [*Acoustics — Laboratory measurement of the reduction of transmitted impact noise by floor coverings on a small floor mock-up — Part 1: Heavyweight compact floor*](https://www.iso.org/standard/56017.html) (ISO 16251-1:2014).
  The small-mock-up laboratory method for the impact-sound improvement ΔL of soft, locally-reacting floor coverings, with ΔL_w via the ISO 717-2 reference floor and the CI,delta adaptation term.
- **International Organization for Standardization. (2017).** [*Building acoustics — Estimation of acoustic performance of buildings from the performance of elements — Part 2: Impact sound insulation between rooms*](https://www.iso.org/standard/70243.html) (ISO 12354-2:2017).
  The informative Annex C floating-floor estimate reproduced on this page (Formulae C.1 to C.4, the 160 sqrt(s'/m') resonance) and the worked floor of its Annex G.
- **International Organization for Standardization. (2020).** [*Acoustics — Rating of sound insulation in buildings and of building elements — Part 2: Impact sound insulation*](https://www.iso.org/standard/69867.html) (ISO 717-2:2020).
  The impact single-number rating engine reused here and the reference floor L_n,r,0 (Table 4) behind ΔL_w, with the Formula (A.4) spectrum adaptation term CI,delta.
- **Vigran, T. E. (2008).** *Building acoustics*. CRC Press. https://doi.org/10.1201/9781482266016
  The transmission theory of floors and floating floors that the improvement quantifies. ISBN 978-0-415-42853-8.